T0-2-15907/I1/SVA(C,E,G-J) 207096 EATON ELECTRIC Changeoverswitches, 4 pole, 20 A, Cylinder lock SVA, front .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

T0-2-15907/I1/SVA(C,E,G-J) 207096 EATON ELECTRIC Changeoverswitches, 4 pole, 20 A, Cylinder lock SVA, front ..

T0-2-15907/I1/SVA(C,E,G-J)

207096

EATON-MOELLER

Changeoverswitches, 4 pole, 20 A, Cylinder lock SVA, front plate AUTO-0-HAND

T0-2-15907/I1/SVA(C,E,G-J)

Changeoverswitches, T0, 20 A, surface mounting, 4 pole, with black thumb grip and front plate, Cylinder lock SVA

More details


Low-voltage industrial components > Control switch

Disconnectors and Cam Switches

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $151.38
Unit price: $151.38

Quantity Price
1+$151.38
2+$132.37
3+$130.23
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Changeoverswitches, T0, 20 A, surface mounting, 4 pole, with black thumb grip and front plate, Cylinder lock SVA
Changeover switch, Product range: Switch with locking mechanism, Standards: IEC/EN 60947, VDE 0660, IEC/EN 60204, Switch-disconnector according to IEC/EN 60947-3, Part group reference: T0, with black thumb grip and front plate, with two keys, 4 pole, Cylinder lock SVA, Locking facility: Lockable in position 0 with cover interlock, Degree of Protection: IP65, Design: surface mounting, Switching angle: 45 °, Switching performance: momentary/maintained, 2 contact unit(s), Rated uninterrupted current: Iu= 20 A, Notes: If the key is withdrawn in HAND position, START can be actuated without the key, but not 0., front plate: AUTO-0-HAND

Delivery program

Product range
Switch with locking mechanism
Part group reference
T0
Basic function
Changeoverswitches
with black thumb grip and front plate
Information about equipment supplied
with two keys
Number of poles
4 pole
locking arrangement
Cylinder lock SVA
Notes
If the key is withdrawn in HAND position, START can be actuated without the key, but not 0.
Locking facility
Lockable in position 0 with cover interlock
Degree of Protection
IP65
000Z083
Design
surface mounting
000Z078
Contact sequence
115S325-2
Switching angle
45 °
Switching performance
momentary/maintained
Design number
15907
Front plate no.
115K030
front plate
AUTO-0-HAND<START
Motor rating AC-23A, 50 - 60 Hz [P]
400 V [P]
5.5 kW
Rated uninterrupted current [Iu]
20 A
Note on rated uninterrupted current !u
Rated uninterrupted current Iuis specified for max. cross-section.
Number of contact units
2 contact unit(s)

Technical data

General
Standards
IEC/EN 60947, VDE 0660, IEC/EN 60204
Switch-disconnector according to IEC/EN 60947-3
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperatureEnclosed
-25 - +40 °C
Overvoltage category/pollution degree
III/3
Rated impulse withstand voltage [Uimp]
6000 V AC
Mechanical shock resistance
15 g
Mounting position
As required
Contacts
Mechanical variablesNumber of poles
4 pole
Electrical characteristicsRated operational voltage [Ue]
690 V AC
Electrical characteristicsRated uninterrupted current [Iu]
20 A
Electrical characteristicsNote on rated uninterrupted current !u
Rated uninterrupted current Iuis specified for max. cross-section.
Load rating with intermittent operation, class 12AB 25 % DF
2 x Ie
Load rating with intermittent operation, class 12AB 40 % DF
1.6 x Ie
Load rating with intermittent operation, class 12AB 60 % DF
1.3 x Ie
Short-circuit ratingFuse
20 A gG/gL
Rated short-time withstand current (1 s current) [Icw]
320 Arms
Note on rated short-time withstand current lcw
Current for a time of 1 second
Rated conditional short-circuit current [Iq]
6 kA
Switching capacity
cos ϕ rated making capacity as per IEC 60947-3
130 A
Rated breaking capacity cos ϕ to IEC 60947-3230 V
100 A
Rated breaking capacity cos ϕ to IEC 60947-3400/415 V
110 A
Rated breaking capacity cos ϕ to IEC 60947-3500 V
80 A
Rated breaking capacity cos ϕ to IEC 60947-3690 V
60 A
Safe isolation to EN 61140between the contacts
440 V AC
Safe isolation to EN 61140Current heat loss per contact at Ie
0.6 W
Safe isolation to EN 61140Current heat loss per auxiliary circuit at Ie(AC-15/230 V)
0.6 CO
Lifespan, mechanical [Operations]
> 0.4 x 106
Maximum operating frequency [Operations/h]
1200
ACAC-3Rating, motor load switch [P]220 V 230 V [P]
3 kW
ACAC-3Rating, motor load switch [P]230 V Star-delta [P]
5.5 kW
ACAC-3Rating, motor load switch [P]400 V 415 V [P]
5.5 kW
ACAC-3Rating, motor load switch [P]400 V Star-delta [P]
7.5 kW
ACAC-3Rating, motor load switch [P]500 V [P]
5.5 kW
ACAC-3Rating, motor load switch [P]500 V Star-delta [P]
7.5 kW
ACAC-3Rating, motor load switch [P]690 V [P]
4 kW
ACAC-3Rating, motor load switch [P]690 V Star-delta [P]
5.5 kW
ACAC-3Rated operational current motor load switch230 V [Ie]
11.5 A
ACAC-3Rated operational current motor load switch230 V star-delta [Ie]
20 A
ACAC-3Rated operational current motor load switch400V 415 V [Ie]
11.5 A
ACAC-3Rated operational current motor load switch400 V star-delta [Ie]
20 A
ACAC-3Rated operational current motor load switch500 V [Ie]
9 A
ACAC-3Rated operational current motor load switch500 V star-delta [Ie]
15.6 A
ACAC-3Rated operational current motor load switch690 V [Ie]
4.9 A
ACAC-3Rated operational current motor load switch690 V star-delta [Ie]
8.5 A
ACAC-21ARated operational current switch440 V [Ie]
20 A
ACAC-23AMotor rating AC-23A, 50 - 60 Hz [P]230 V [P]
3 kW
ACAC-23AMotor rating AC-23A, 50 - 60 Hz [P]400 V 415 V [P]
5.5 kW
ACAC-23AMotor rating AC-23A, 50 - 60 Hz [P]500 V [P]
7.5 kW
ACAC-23AMotor rating AC-23A, 50 - 60 Hz [P]690 V [P]
5.5 kW
ACAC-23ARated operational current motor load switch230 V [Ie]
13.3 A
ACAC-23ARated operational current motor load switch400 V 415 V [Ie]
13.3 A
ACAC-23ARated operational current motor load switch500 V [Ie]
13.3 A
ACAC-23ARated operational current motor load switch690 V [Ie]
7.6 A
DCDC-1, Load-break switches L/R = 1 msRated operational current [Ie]
10 A
DCDC-1, Load-break switches L/R = 1 msVoltage per contact pair in series
60 V
DCDC-21A [Ie]Rated operational current [Ie]
1 A
DCDC-21A [Ie]Contacts
1 Quantity
DCDC-23A, motor load switchL/R = 15 ms24 VRated operational current [Ie]
10 A
DCDC-23A, motor load switchL/R = 15 ms24 VContacts
1 Quantity
DCDC-23A, motor load switchL/R = 15 ms48 VRated operational current [Ie]
10 A
DCDC-23A, motor load switchL/R = 15 ms48 VContacts
2 Quantity
DCDC-23A, motor load switchL/R = 15 ms60 VRated operational current [Ie]
10 A
DCDC-23A, motor load switchL/R = 15 ms60 VContacts
3 Quantity
DCDC-23A, motor load switchL/R = 15 ms120 VRated operational current [Ie]
5 A
DCDC-23A, motor load switchL/R = 15 ms120 VContacts
3 Quantity
DCDC-23A, motor load switchL/R = 15 ms240 VRated operational current [Ie]
5 A
DCDC-23A, motor load switchL/R = 15 ms240 VContacts
5 Quantity
DCDC-13, Control switches L/R = 50 msRated operational current [Ie]
10 A
DCDC-13, Control switches L/R = 50 msVoltage per contact pair in series
32 V
Control circuit reliability at 24 V DC, 10 mA [Fault probability]
< 10-5,< 1 failure in 100,000 switching operations HF
Terminal capacities
Solid or stranded
1 x (1 - 2,5)
2 x (1 - 2,5) mm2
Flexible with ferrules to DIN 46228
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Terminal screw
M3.5
Tightening torque for terminal screw
1 Nm
Technical safety parameters:
Notes
B10dvalues as per EN ISO 13849-1, table C1
Rating data for approved types
Terminal capacityTerminal screw
M3.5
Terminal capacityTightening torque
8.83 lb-in

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
20 A
Heat dissipation per pole, current-dependent [Pvid]
0.6 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+40 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
UV resistance only in connection with protective shield.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Control switch (EC002611)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Control switch ([email protected] [ACN998011])
Type of switch
Reverser
Number of poles
0
Max. rated operation voltage Ue AC
690 V
Rated permanent current Iu
20 A
Number of switch positions
4
With 0 (off) position
Yes
With retraction in 0-position
No
Device construction
Surface mounted device
Width in number of modular spacings
0
Suitable for ground mounting
Yes
Suitable for front mounting 4-hole
No
Suitable for distribution board installation
No
Suitable for intermediate mounting
No
Complete device in housing
Yes
Type of control element
Toggle
Front shield size
48x48 mm
Degree of protection (IP), front side
IP65
Degree of protection (NEMA), front side
Other

Dimensions

115X039
SVA-T3
② ZFS-... Label mount not included as standard
115X040

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.