INX16B3-06W 123073 EATON ELECTRIC Switch-disconnector, 3p, 630A, withdrawable View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

INX16B3-06W 123073 EATON ELECTRIC Switch-disconnector, 3p, 630A, withdrawable

INX16B3-06W

123073

EATON-MOELLER

Switch-disconnector, 3p, 630A, withdrawable

More details


Home > EATON - MOELLER

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Delivery programme
Product range
Air circuit-breakers/switch-disconnectors
Product range
Open switch-disconnectors
Current Range
Up to 4000 A
Protective function
Switch disconnector
Installation type
Withdrawable
Construction size
INX16
Release system
without releases
Standard/Approval
IEC
Number of poles
3 pole
Degree of Protection
IP20, IP55 with protective cover, IP41 door sealing frame
optionally fittable by user with comprehensive accessories
Rated current = rated uninterrupted current
In= Iu A 630
Making capacity Icm to 440 V 50/60 Hz
Icm kA 88
t = 1 s
Icw kA 42
Notes

Note ????

Note concerning the product 

Cassette needs to be ordered separately.

Technical data
General
Standards
IEC/EN 60947
Ambient temperature
Storage
ϑ °C -40 - +70
Ambient temperature
°C -25 - +70
Mounting position
Technical data for design verification
Rated operational current for specified heat dissipation
In A 630
Equipment heat dissipation, current-dependent
Pvid W 50
Operating ambient temperature min.
°C -25
Operating ambient temperature max.
°C 70
IEC/EN 61439 design verification
10.2 Strength of materials and parts
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 6.0
Low-voltage industrial components (EG000017) / Switch disconnector (EC000216)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Switch disconnector ([email protected] [AKF060010])
Version as main switch
Yes
Version as maintenance-/service switch
No
Version as safety switch
No
Version as emergency stop installation
No
Version as reversing switch
No
Max. rated operation voltage Ue AC
V 690
Rated operating voltage
V 690 - 690
Rated permanent current Iu
A 630
Rated permanent current at AC-21, 400 V
A 0
Rated operation power at AC-3, 400 V
kW 0
Rated short-time withstand current lcw
kA 42
Rated operation power at AC-23, 400 V
kW 0
Switching power at 400 V
kW 0
Conditioned rated short-circuit current Iq
kA 88
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
2
Motor drive optional
Yes
Motor drive integrated
No
Voltage release optional
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for ground mounting
Yes
Suitable for front mounting 4-hole
No
Suitable for front mounting center
No
Suitable for distribution board installation
Yes
Suitable for intermediate mounting
No
Colour control element
Green
Type of control element
Push button
Interlockable
Yes
Type of electrical connection of main circuit
Rail connection
Degree of protection (IP), front side
IP20

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.