TM-1-8240/E 058267 EATON ELECTRIC Step switches, Contacts: 2, 10 A, front plate: 0-1-2, 60 °, 2 steps, 60°, .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

TM-1-8240/E 058267 EATON ELECTRIC Step switches, Contacts: 2, 10 A, front plate: 0-1-2, 60 °, 2 steps, 60°, ..

TM-1-8240/E

058267

EATON-MOELLER

Step switches, Contacts: 2, 10 A, front plate: 0-1-2, 60 °, 2 steps, 60°, maintained, flush mounting

Step switches, TM, 10 A, flush mounting, 1 contact unit(s), Contacts: 2, 60 °, maintained, With 0 (Off) position, 0-1-2, design no. 8240

More details


Low-voltage industrial components > Control switch

Disconnectors and Cam Switches

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $51.87
Unit price: $51.87

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Step switches, TM, 10 A, flush mounting, 1 contact unit(s), Contacts: 2, 60 °, maintained, With 0 (Off) position, 0-1-2, design no. 8240
Step switch, Product range: Control switches, Standards: IEC/EN 60947, VDE 0660, CSA, UL, Control switch as per IEC/EN 60947-5-1, Auxiliary switch as per IEC/EN 60947-5-1, Part group reference: TM, with black thumb grip and front plate, Contacts: 2, Number of steps: 2 steps, 60°, Degree of Protection: Front IP65, Design: flush mounting, Switching angle: 60 °, Switching performance: maintained, With 0 (Off) position, 1 contact unit(s), Rated uninterrupted current: Iu= 10 A, front plate: 0-1-2

Delivery program

Product range
Control switches
Part group reference
TM
Basic function
Step switches
with black thumb grip and front plate
Contacts
2
Number of steps
2 steps, 60°
Degree of Protection
Front IP65
Design
flush mounting
000Z079
Contact sequence
115S027-2
Switching angle
60 °
Switching performance
maintained
With 0 (Off) position
Design number
8240
Front plate no.
115K186
front plate
0-1-2
Motor rating AC-23A, 50 - 60 Hz [P]
400 V [P]
3 kW
Rated uninterrupted current [Iu]
10 A
Note on rated uninterrupted current !u
Rated uninterrupted current Iuis specified for max. cross-section.
Number of contact units
1 contact unit(s)

Technical data

General
Standards
IEC/EN 60947, VDE 0660, CSA, UL
Control switch as per IEC/EN 60947-5-1
Auxiliary switch as per IEC/EN 60947-5-1
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperatureOpen
-25 - +50 °C
Overvoltage category/pollution degree
III/3
Rated impulse withstand voltage [Uimp]
4000 V AC
Mounting position
As required
Contacts
Electrical characteristicsRated operational voltage [Ue]
500 V AC
Electrical characteristicsRated uninterrupted current [Iu]
10 A
Electrical characteristicsNote on rated uninterrupted current !u
Rated uninterrupted current Iuis specified for max. cross-section.
Short-circuit ratingFuse
10 A gG/gL
Switching capacity
Safe isolation to EN 61140Current heat loss per contact at Ie
0.15 W
Safe isolation to EN 61140Current heat loss per auxiliary circuit at Ie(AC-15/230 V)
0.15 CO
Lifespan, mechanical [Operations]
> 1 x 106
Maximum operating frequency [Operations/h]
1200
ACAC-21ARated operational current switch400 V 415 V [Ie]
10 A
ACAC-23AMotor rating AC-23A, 50 - 60 Hz [P]400 V 415 V [P]
3 kW
Control circuit reliability at 24 V DC, 10 mA [Fault probability]
< 10-5,< 1 failure in 100,000 switching operations HF
Terminal capacities
Solid or stranded
1 x 1,5
2 x 1,5 mm2
Flexible with ferrules to DIN 46228
1 x 1.0
2 x 1.0 mm2
Flexible
1 x 1.5
2 x 1.5 mm2
Terminal screw
M2.5
Tightening torque for terminal screw
0.4 Nm
Rating data for approved types
ContactsRated operational voltage [Ue]
300 V AC
ContactsRated uninterrupted current max.Main conducting pathsGeneral use
10 A
ContactsRated uninterrupted current max.Auxiliary contactsGeneral Use [IU]
10 A
ContactsRated uninterrupted current max.Auxiliary contactsPilot Duty
A 300
Switching capacityMaximum motor ratingSingle-phase120 V AC
0.33 HP
Switching capacityMaximum motor ratingSingle-phase240 V AC
0.75 HP
Switching capacityMaximum motor ratingSingle-phase277 V AC
0.75 HP
Switching capacityMaximum motor ratingThree-phase120 V AC
0.75 HP
Switching capacityMaximum motor ratingThree-phase240 V AC
1 HP
Terminal capacitySolid or flexible conductor with ferrule
14 AWG
Terminal capacityTerminal screw
M2.5
Terminal capacityTightening torque
3.5 lb-in

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
10 A
Heat dissipation per pole, current-dependent [Pvid]
0.15 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+50 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
UV resistance only in connection with protective shield.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Control switch (EC002611)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Control switch ([email protected] [ACN998011])
Type of switch
Level switch
Number of poles
1
Max. rated operation voltage Ue AC
500 V
Rated permanent current Iu
10 A
Number of switch positions
3
With 0 (off) position
Yes
With retraction in 0-position
No
Device construction
Built-in device
Width in number of modular spacings
0
Suitable for ground mounting
No
Suitable for front mounting 4-hole
Yes
Suitable for distribution board installation
No
Suitable for intermediate mounting
No
Complete device in housing
No
Type of control element
Toggle
Front shield size
30x30 mm
Degree of protection (IP), front side
IP65
Degree of protection (NEMA), front side
Other

Approvals

Product Standards
UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94; IEC/EN 60947-3; CE marking
UL File No.
E36332
UL Category Control No.
NLRV
CSA File No.
UL report applies to both US and Canada
North America Certification
UL listed, certified by UL for use in Canada
Degree of Protection
IEC: IP65; UL/CSA Type: –

Dimensions

115X330
115X071
Door drilling dimensions

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.