SPRT12-264/3-AX 183183 EATON ELECTRIC Combined arrester, transient voltage surge suppression T1&T2 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

SPRT12-264/3-AX 183183 EATON ELECTRIC Combined arrester, transient voltage surge suppression T1&T2

SPRT12-264/3-AX

183183

EATON-MOELLER

Combined arrester, transient voltage surge suppression T1&T2;

More details


Modular Switchgear – Industrial

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Combined arrester, transient voltage surge suppression T1&T2;
Multi-pole combined arrester, type 1 as specified in EN 61643-11, spark-gap-based, consisting of base and plug-in protection modules. Maximum system availability ensured by means of RADAX Flow follow current limiting. Allows for end-device protection. For protecting low-voltage consumer installations from overvoltages, even in the event of direct lightning strikes. Application according to lightning protection zone approach at interfaces 0A– 2.
[

Delivery program

Products
Surge arresters
Application field
Residential buildings
Utility buildings
Open areas
,

Technical data ETIM 6.0

Earthing, lightning and surge protection (EG000021) / Combined arrester for power supply systems (EC001457)
Electric engineering, automation, process control engineering / Protection installation, device (electric) / Surge protection device (inner lightning protection) / Combined lightning current/surge arrester f. power supply s. ([email protected] [ACN284008])
System configuration DC
No
System configuration IT
Yes
System configuration TN
Yes
System configuration TN-C
Yes
System configuration TN-C-S
Yes
System configuration TN-S
No
System configuration TT
No
System configuration other
Yes
Number of poles
3
Lightning impulse current (10/350)
75 kA
Max. continuous voltage AC
264 V
Max. continuous voltage DC
0 V
Nominal voltage AC
230 V
Nominal voltage DC
0 V
Max. PV-voltage
0 V
Voltage protection level
1.5 kV
Voltage protection level L-N
1.5 kV
Voltage protection level N-PE
0 kV
Voltage protection level (DC+ - DC-)
0 kV
Voltage protection level (DC+/DC- - PE)
0 kV
Follow current extinguishing capability
50 kA
Specific energy (W/R)
1400 kJ/Ohm
Max. conductor cross section solid (solid, stranded)
50 mm²
Max. conductor cross section flexible (fine-strand)
35 mm²
Mounting method
DIN rail (top hat rail) 35 mm
Construction size
6 modular spacing
Remote signalling
Yes
Signalling at the device
Optic
Test class
Type 1 + 2
Exhausting
No
Integrated backup fuse
No
Energy-coordinated protection effect with regard to the terminal equipment
Yes
]

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.