NZM4-XA110-130AC/DC 266450 EATON ELECTRIC Shunt release, 110-130VAC/DC View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

NZM4-XA110-130AC/DC 266450 EATON ELECTRIC Shunt release, 110-130VAC/DC

NZM4-XA110-130AC/DC

266450

EATON-MOELLER

Shunt release, 110-130VAC/DC

NZM4-XA110-130AC/DC

More details


Low-voltage industrial components > Shunt release (for power circuit breaker)

Circuit Breakers NZM Accessories

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $174.49
Unit price: $174.49

Quantity Price
1+$174.49
2+$159.63
3+$153.58
4+$153.52
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Often bought together

More info



Shunt release, 110-130VAC/DC
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: switches are tripped by a voltage pulse or by the application of uninterrupted voltage. If the shunt release is energized, accidental contact with the main contacts of the switch during attempts to switch on is safely prevented.undervoltage releases cannot be installed simultaneously with NZM..-XHIV.. early-make auxiliary contact or NZM..-XU.. shunt release. Can be used for: NZM4(-4), N(N/O)4(-4)

Delivery program

Product range
Accessories
Accessories
Shunt release
Accessories
Shunt releases
Standard/Approval
UL/CSA, IEC
Construction size
NZM4
Description
Switches are tripped by a voltage pulse or by the application of uninterrupted voltage.
If the shunt trip is live, contact with the circuit breaker’s primary contacts is prevented when switched on.
Shunt releases cannot be installed simultaneously with NZM...-XHIV... early-make auxiliary contact or NZM...-XU... undervoltage release.
Connection type
With bolt connection
Auxiliary contacts
without auxiliary contact
Rated control voltage [Us]
110 - 130 V AC/DC V
For use with
NZM4(-4), N(S)4(-4)

Technical data

Shunt release
Rated control voltage [Us]AC [Us]
110-130 V AC
Rated control voltage [Us]DC [Us]
110-130 V DC
Frequency
50/60/200/400, DC Hz
Operating rangeAC [x Us]
0.7 - 1.1
Operating rangeDC [x Us]
0.7 - 1.1
Power consumptionPick-up AC/DC
2.5 VA/W
Power consumptionPower consumption Pick-up = Sealing
2.5 VA/W
Maximum opening delay (response time until opening of the main contacts)
22 ms
Maximum duty factor
∞ ms
Minimum command time
10 … 15 ms
Terminal capacitiesSolid or flexible conductor, with ferrule
1 x (0,75 - 2,5)
2 x (0,75 - 2,5) mm2
Terminal capacities
1 x (18 … 14)
2 x (18 … 14) AWG

Design verification as per IEC/EN 61439

IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Shunt release (for power circuit breaker) (EC001023)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Full load current trip ([email protected] [AKF016013])
Rated control supply voltage Us at AC 50HZ
110 - 130 V
Rated control supply voltage Us at AC 60HZ
110 - 130 V
Rated control supply voltage Us at DC
110 - 130 V
Voltage type for actuating
AC/DC
Initial value of the undelayed short-circuit release - setting range
0 A
End value adjustment range undelayed short-circuit release
0 A
Type of electric connection
Screw connection
Number of contacts as normally open contact
0
Number of contacts as normally closed contact
0
Number of contacts as change-over contact
0
Suitable for power circuit breaker
Yes
Suitable for off-load switch
Yes
Suitable for motor safety switch
No
Suitable for overload relay
No

Approvals

Product Standards
UL489; CSA-C22.2 No. 5-09; IEC60947, CE marking
UL File No.
E140305
UL Category Control No.
DIHS
CSA File No.
022086
CSA Class No.
1437-01
North America Certification
UL listed, CSA certified

Datasheet - PDF

Title: Size: Type:
NZM4-XA110-130AC/DC 266450 EN_266450.pdf 153 Kbytes   NZM4-XA110-130AC/DC  266450 EN_266450.pdf

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.