ES4P-221-DMXX1 111016 0004521511 EATON ELECTRIC Safety relay, 24 V DC, 14DI, 4DO-Trans, 1DO relay, display, .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

ES4P-221-DMXX1 111016 0004521511 EATON ELECTRIC Safety relay, 24 V DC, 14DI, 4DO-Trans, 1DO relay, display, ..

ES4P-221-DMXX1

111016

0004521511

EATON-MOELLER

Safety relay, 24 V DC, 14DI, 4DO-Trans, 1DO relay, display, easyNet

ES4P-221-DMXX1

More details


PLC's > Logic module

EASY programmable relays and MFD displays

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $1,064.44
Unit price: $1,064.44

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Safety relay, 24 V DC, 14DI, 4DO-Trans, 1DO relay, display, easyNet
Extendable control relay suitable for safety circuits, rated operating voltage 24VDC, 14 safety digital inputs, 1 safe and redundant relay output 6A, 4 transistor outputs 0.5A, 4 test signal outputs, suitable for cat. 4 according to EN 954-1 / PL e according to EN ISO 13849-1 / SILCL3 according to IEC 62061 / SIL3 according to IEC61508, degree of protection IP20, no keypad, no LCD display, safety and standard functionality integrated into a device, bus system easyNet on board, easyLink, expandable with digital inputs and outputs, expandable to the bus systems AS-Interface, PROFIBUS-DP, integrated, deviceNet , custom labeling of control relay with inscription software Label editor

General specifications
Product name
Eaton Moeller® series ES4P Safety relay
Part no.
ES4P-221-DMXX1
EAN
4015081105267
Product Length/Depth
72 millimetre
Product height
90 millimetre
Product width
108 millimetre
Product weight
0.324 kilogram
Compliances
CE Marked
Certifications
UL Listed
EN Listed
CSA Certified
IEC 61508
CSA Class No.: 2252-81; 2252-01
UL Category Control No.: NRAQ
CSA-22.2 No. 142-MI1987
IEC 62061
EN 50156-1
CSA-C22.20.4-04
UL File No.: CSA report applies to both US and Canada
EN 50178
EN 50156-2
CE
IEC/EN 61000-4-2
CSA
CSA File No.: 012528
IEC/EN 61000-6-2
UL 508
IEC/EN 61000-6-3
EN ISO 13849-1
EN 50581
Product Tradename
ES4P
Product Type
Safety relay
Product Sub Type
None
Catalog Notes
1000
Features & Functions
Features
Expandable
Safety/standard circuit diagram
Fitted with:
Timer
Real time clock
Relay output
Expandable standard inputs/outputs
Expandable standard bus systems
Functions
Redundancy
Thermal cutout
Inscription
Individual laser inscriptions possible
General information
Accuracy
± 5 s/day depending on the ambient temperature
± 2 s/day (± 0.5 h⁄year), Real-time clock, normally
Cable length
1000 m, shielded, Single cable length of test signal output to the device input, Digital inputs 24 V DC
3000 m, shielded, Total of single cable lengths from one test signal output to the device inputs, Digital inputs 24 V DC
50 m, unscreened, Transistor outputs
100 m, unscreened, Digital inputs 24 V DC
Degree of protection
IP20
Duty factor
T0.95 ≈ 3 x T0.65 = 3 x L/R (Inductive load to EN 60947-5-1, Without external suppressor circuit)
T0.95 = Time in ms, until 95 % of the steady-state current has been reached (Inductive load to EN 60947-5-1, Without external suppressor circuit)
100 % (Inductive load to EN 60947-5-1, With external suppressor circuit)
Insulation resistance
According to EN 50178
Lifespan, mechanical
10,000,000 Operations
10,000,000 Operations (Relay outputs)
Mounting method
Screw fixing using fixing brackets ZB4-101-GF1 (accessories)
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Rail mounting possible
Wall mounting/direct mounting
Mounting width
107.5 mm
Operating frequency
Resistive load < 100 kΩ, depending on program and load
900 Operations/h at input (does not apply to I1, I2, if function block SM or OM is used)
13500 Operations/h at resistive load
Overvoltage category
III
Pollution degree
2
Product category
Control relays for safety applications
Rated impulse withstand voltage (Uimp)
6 kV (contact-coil)
Residual ripple
5 % (transistor outputs)
≤ 5 %
Resolution
1 min (Range H:M)
1 s (Range M:S)
50 ms (Range S)
Suitable for
Safety functions
Switching capacity
AC: R300 (in accordance with UL 508), Relay outputs
AC-15, 230 V AC, 3 A: 80000 operations (in accordance with IEC 60947-5-1), Relay outputs
DC: B300 (in accordance with UL 508), Relay outputs
DC-13, 24 V DC, 0.1 Hz: 40000 operations (in accordance with IEC 60947-5-1), Relay outputs
Switching frequency
15 Hz, Relay outputs
0.5 Hz, Transistor outputs, Inductive load to EN 60947-5-1, with external suppressor circuit, Max. switching frequency, max. duty factor = 50%
Type
easy800 with safety function blocks
Voltage type
DC
Ambient conditions, mechanical
Constant acceleration
2 g, 57 - 150 Hz
Constant amplitude
0,15 mm, 10 - 57 Hz, according to IEC/EN 60068-2-6, Vibrations
Drop and topple
50 mm Drop height, Drop to IEC/EN 60068-2-31
Height of fall (IEC/EN 60068-2-32) - max
0.3 m
Shock resistance
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 18 Impacts
Vibration resistance
3.5 mm / 1 g, According to IEC/EN 60068-2-6
Climatic environmental conditions
Air pressure
795 - 1080 hPa (operation)
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
55 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
70 °C
Environmental conditions
Condensation: prevent with appropriate measures
Clearance in air and creepage distances according to EN 50178, UL 508, CSA C22.2, No. 142, EN 60664-1:2003
Relative humidity
5 - 95 % (non-condensing, IEC 60068-2-30, IEC 60068-2-78)
Electro magnetic compatibility
Air discharge
15 kV
Burst impulse
4 kV, Supply cable
According to IEC/EN 61000-4-4
4 kV, Signal cable
Contact discharge
8 kV
Electromagnetic compatibility
Increased EMC requirements for safety-relevant functions (according to ICE 62061)
Electromagnetic fields
30 V/m (according to IEC EN 61000-4-3)
1 V/m at 2 - 2.7 GHz (according to IEC EN 61000-4-3)
10 V/m at 0.08 - 1.0 GHz (according to IEC EN 61000-4-3)
3 V/m at 1.4 - 2 GHz (according to IEC EN 61000-4-3)
Immunity to line-conducted interference
20 V (according to IEC/EN 61000-4-6)
Radio interference class
Class B (EN 55022)
Class B (EN 55011)
Surge rating
According to IEC/EN 61000-4-5, power pulses (Surge), EMC
4 kV, semi-conductor outputs, symmetrical, power pulses (Surge), EMC
2 kV, Supply cables, symmetrical, power pulses (Surge), EMC
Voltage dips
≤ 10 ms
According to EN 61131-2
Terminal capacities
Terminal capacity
0.2 - 4 mm² (AWG 22 - 12), solid
0.2 - 2.5 mm² (22 - 12 AWG), flexible with ferrule
Tightening torque
0.6 Nm, Screw terminals
Screwdriver size
3.5 x 0.8 mm, Terminal screw
Electrical rating
Conventional thermal current ith of auxiliary contacts (1-pole, open)
6 A
Input current
< 250 mA (at 115/230 V AC)
5.7 mA (Digital inputs, at 24 V DC, at signal 1, I1 - I6)
Output voltage
24 V DC (test signal outputs)
U = Uₑ - 1 V (signal 1 at Iₑ = 0.5 A, transistor outputs)
Output Voltage@≤ 2.4 V (at signal 0 at external load < 10 MΩ, transistor outputs)
Peak short-circuit current
16 A
Rated control supply voltage
24 V DC (Us)
Rated insulation voltage (Ui)
250 V
Rated operational current (Ie)
Max. 0.5 A at signal „1” DC per channel
Rated operational voltage
250 V AC
20.4 - 28.8 V DC
24 V DC (transistor outputs)
20.4 - 28.8 V DC (Transistor outputs)
24 V DC (digital inputs)
24 V DC (-15 %/+ 20 % - power supply)
< 5 V DC on 0 signal
> 15 V DC on 1 signal
Short-circuit current
8 A, Transistor outputs
Short-circuit protection
Yes, Transistor outputs
≤ 8 A, Back-up fuse, Transistor outputs
Short-circuit tripping current
0.7 ≤ Ie ≤ 2 per output, For Ra ≤ 10 mΩ, Transistor outputs
Supply current
60/100 mA, Normally⁄max., On 1 signal, Transistor outputs
50/50 mA, Normally⁄max., On 0 signal, Transistor outputs
Supply voltage at AC, 50 Hz - min
0 V AC
Supply voltage at AC, 50 Hz - max
0 V AC
Supply voltage at DC - min
20.4 V DC
Supply voltage at DC - max
28.8 V DC
Communication
Bus termination
First and last station, easyNet
Data transfer rate
20 kBit/s, 700 m, easyNet
1000 kBit/s, 6 m, easyNet
10 kBit/s, 1000 m, easyNet
500 kBit/s, 25 m, easyNet
50 kBit/s, 300 m, easyNet
250 kBit/s, 40 m, easyNet
125 kBit/s, 125 m, easyNet
Memory
100,000,000,000,000 Write cycles of the retentive memory
Module interface
easyNet/easyLink
Number of modules
Max. 8
Protocol
Other bus systems
Input/Output
Capacitive load
0.6 µF max., Transistor outputs
Lamp load
5 W (without Rv per channel)
Number of inputs (analog)
0
Number of inputs (digital)
14
Number of outputs (analog)
4
Number of outputs (digital)
5
Off-delay
< 1 ms
Output
4 Test signal outputs (T1 - T4)
4 Transistor Outputs
Relay outputs in groups of 1
Parallel switching
Not permitted
Pulse characteristics
1 ms (max. duration of external test pulse)
1 ms (Off test pulse)
Utilization factor
1 (Inductive load to EN 60947-5-1, With external suppressor circuit)
Safety
Explosion safety category for dust
None
Explosion safety category for gas
None
Potential isolation
Between easyNet and Power supply: yes
Between Digital inputs 24 V DC and easyNet: yes
Between Transistor outputs and easyLink: yes
Between Relay outputs and easyNet: yes
Between Relay outputs and Power supply: yes
Between Transistor output and interface: yes
Between Digital inputs 24 V DC and Outputs: yes
Between easyNet and Outputs: yes
Between Power supply and easyNet: yes
Between Relay outputs and Digital inputs: yes
Between Inputs and internal Power supply: Yes
Between Power supply and Inputs: yes
Between Relay outputs and Inputs: yes
Between easyNet and Inputs: yes
Between easyNet and PC interface: yes
Basic isolation: 600 V AC (Relay outputs)
Between Relay outputs and Interface: yes
Between easyNet and Memory card: yes
Safe isolation according to EN 50178: 300 V AC (Relay outputs)
Between Power supply and Outputs: yes
Protection
!
Protection of an Output relay - Fuse: 6 A gL/gG, Circuit-breaker with C characteristic: 4 A (only permissible with 24V DC), Short-circuit current IK: < 250 A
Protection against polarity reversal
Yes
Safe isolation
Between coil and contacts in accordance with EN 50178
300 V AC, Between coil and contacts, According to EN 50178
Safety function/level
Enabling switch
Two-hand control
Protective door
OSSD input
3 redundant relay outputs, 6 months test interval
Stopping in the event of an emergency
Zero speed monitoring
Highest speed monitoring
Safety timing relay
Mode selection
Feedback circuit
According to EN 50156
ESPE with muting function
Safety parameter (EN ISO 13849-1)
Cat. 4, Category
PL e, Performance level
Safety parameter (IEC 62061)
SILCL 3, Safety integrity level claim limit
23 x 10-10, PFHd, Probability of failure per hour
SIL 3, Safety integrity level, In accordance with IEC 61508
Design verification
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
6 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 9.0

Programmable logic controllers PLC (EG000024) / Logic module (EC001417)
Electric engineering, automation, process control engineering / Control, Process Control System (PCS) / Programmable logic control (SPS) / Logic module (ecl@ss13-27-24-22-16 [AKE539019])
Supply voltage AC 50 Hz
0 - 0 V
Supply voltage AC 60 Hz
0 - 0 V
Supply voltage DC
20.4 - 28.8 V
Voltage type (supply voltage)
DC
Switching current
8 A
Power consumption
4 W
Number of analogue inputs
0
Number of analogue outputs
4
Number of digital inputs
14
Number of digital outputs
5
With relay output
Yes
Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
1
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of HW-interfaces wireless
0
Number of HW-interfaces other
3
With optical interface
No
Supporting protocol for EtherCAT
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for Modbus
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
Yes
Radio standard Bluetooth
No
Radio standard WLAN 802.11
No
Radio standard GPRS
No
Radio standard GSM
No
Radio standard UMTS
No
IO link master
No
Redundancy
Yes
With display
No
Degree of protection (IP)
IP20
Basic device
Yes
Expandable
Yes
Expansion device
No
With time switch clock
Yes
Rail mounting possible
Yes
Wall mounting/direct mounting
Yes
Front built-in possible
No
Rack-assembly possible
No
Suitable for safety functions
Yes
SIL according to IEC 61508
3
Performance level according to EN ISO 13849-1
Level e
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
Explosion safety category for gas
None
Explosion safety category for dust
None
Certified for UL hazardous location class I
No
Certified for UL hazardous location class II
No
Certified for UL hazardous location class III
No
Certified for UL hazardous location division 1
No
Certified for UL hazardous location division 2
No
Certified for UL hazardous location group A (acetylene)
No
Certified for UL hazardous location group B (hydrogen)
No
Certified for UL hazardous location group C (ethylene)
No
Certified for UL hazardous location group D (propane)
No
Certified for UL hazardous location group E (metal dusts)
No
Certified for UL hazardous location group F (carbonaceous dusts)
No
Certified for UL hazardous location group G (non-conductive dusts)
No
Width
108 mm
Height
90 mm
Depth
72 mm

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.