ANUNCIAR

S711-34480DC EP-401547 EATON ELECTRIC S711 Soft Starter (24VDC)

S711-34480DC

EP-401547

EP-401547

EATON-MOELLER

S711 Soft Starter (24VDC)

Eaton S711 Soft Starter, 480 A, 200 - 600 V AC, Us= 24 V DC, with Control Unit, Size 4, IP00

More details


High Performance Soft Starters

Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total: $5,420.80
Unit price: $5,420.80
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



General Specifications

Product Name
Eaton S711 Soft Starters
Catalog Number
EP-401547
Model Code
S711-34480DC
EAN
4015082970888
Product Length
545 mm
Product Height
204 mm
Product Width
222 mm
Product Weight
19.63 kg
Certifications
EC
RCM
IEC/EN 60947-4-2
ASS
UL
UL Category Control No.: NMFT
UL Category Control No.: NMFT7
UL File No.: E251034
UL 60947-4-2

Features & Functions

Fault memory
1000 Faults
Equipped with:
Display
Motor Protection Relays
Internal bypass
Functions
1 Sense Only
Torque control
DC-Brake
Soft-Brake
Forward & reverse jog
Interfaces
Modbus RTU (built-in)
Bluetooth (built-in)

General information

Class
Adjustable (5,10,15,20,30)
Connection to the SmartWire-DT module
No<
Degree of protection
IP00
Other NEMA
Chassis size
FS4
Min. mains voltage
170 V
Max. mains voltage
632.5 V
Degree of pollution
3
Radio Disturbance Class
Class A (IEC 60947-4-2)
Rated Shock Withstand Voltage (Uimp)
6,000 V
Startup Class
CLASS 20 (heavy starting duty 3 x Iₑ for 45 s)
CLASS 10 (star-delta replacement)
CLASS 30 (6 x Iₑ for 30 s)
Rated Insulation Voltage (Ui)
600 V
Suitable for
Branch circuits, not as BCPD, (UL/cUL)
Type
Soft starter for three-phase loads, with control unit and pump algorithm, DC Brake, Soft Brake, Jog, Bluetooth
Voltage Type
DC

Ambient conditions, mechanical

Mounting position
On request
Impact resistance
15 g, Mechanical

Climatic environmental conditions

Altitude
Max 4000 m (Above 1000 m for detailed derating use S711 Select Software)
Operating Ambient Temperature - Min.
-25°C
Operating Ambient Temperature - Max.
60 °C
Storage Ambient Temperature - Min.
-40°C
Storage room temperature - max.
70 °C
Climate resilience
5 to 95% Relative Humidity

Main conducting paths

Start-up impulse
600% (Kickstart current)
Max. 2000 ms (Kickstart Duration)
Overload Cycle
AC-53b: 3.5-20:580
Rated Operating Current (The) AC-53
480 A
Rated Operating Current (I) AC-53, In-Delta
720 A
Nominal Voltage (Ue) - min.
200 V
Rated voltage (Ue) - max.
575 V
Nominal voltage (Ue) in AC - max.
575 V
Rated Short Circuit Protection Specifications
500NHG3B or NZMH3-AX630, Type "1" coordination, Main conducting paths
170M6011 "Type 2" coordination, Main conducting paths
Feeding frequency
50/60 Hz, fLN, Main Circuit
Rated voltage - max
575 V

Motor rating

Rated motor power at 200/208 V, 60 Hz, three-phase
150 HP
Rated power motor 220/230 V, 60 Hz, three-phase
150 HP
Assigned motor power of 460/480 V, 60 Hz, three-phase
350 HP
In-Delta Motor Rated Power at 220/230 V, 60 Hz
250 HP
Rated power of the In-Delta motor at 460/480 V, 60 Hz
500 HP
Rated motor power of 575/600 V, 60 Hz
700 HP
Rated power at 220/230 V, 50 Hz
150 kW
Rated power at 400 V, 50 Hz
250 kW
Rated power at 400 V, 50 Hz
315 kW
Rated power for use In-Delta at 220/230V, 50 Hz
220 kW
Rated power for use In-Delta at 400 V, 50 Hz
400 kW
Rated power for use In-Delta at 500 V, 50 Hz
500 kW
Three-phase motor rating, standard switching, at 230 V
150 kW
Rated three-phase motor power, standard switching, at 400 V
250 kW
Rated power of three-phase motor, star-delta switching, at 230 V
220 kW
Rated motor power three-phase, star-delta switching, at 400 V
400 kW

Terminal capacities

Connectable section (flexible wire with end cap)
1 x (185 - 400) mm², Main cables
1x (1 - 2.5) mm², Control circuit cables
Connectable section (single-strand)
1 x (185 - 400) mm², Main cables
1x (1 - 2.5) mm², Control circuit cables
Connectable cross-section (AWG single/strand)
1 x (350 - 750), Main cables
1x (28 - 12) , Control circuit cables
Connectable section (multi-strand)
1 x (185 - 400) mm², Main cables
1x (1 - 2.5) mm², Control circuit cables
Screwdriver Size
17 mm M10, Terminal screw, Main cables
0.6 x 3.5 mm or PH0, Terminal screws, Control circuit cables
Tightening torque
0.5 Nm, Screw terminals, Control circuit cables
40 Nm, Main cables

Control circuit

Current consumption
2800 mA, Control circuit, Digital inputs
Opening voltage
0 - 16 V, DC operated
Inrush voltage
19.2 - 28.8 V DC
Nominal Control Supply Voltage (Us) in DC - min.
24 VDC
Nominal Control Supply Voltage (Us) in DC - Max.
24 VDC

Input/Output

Number of Releases
3 Relay Outputs (1 fixed, 2 programmable)
Output voltage
250 V AC (relay outputs)
Rated Control Voltage (Uc)
24 V DC (-20%/+20%)
Rated Operating Current AC-11
3 A

Soft start function

Timer
0 - 180 s, Soft start function, Ramp times; 0 - 240 s, Soft stop function, Stop times
Acceleration/Accumulation Time
180 s
Starting voltage
Max. 600% FLA, Min. 100% FLA, Soft start function

Design verification

Material heat dissipation, Pvid as a function of current
2160 W
Pdiss Heat Dissipation Capability
0 W
Heat dissipation per pole, depending on Pvid current
0 W
Rated Working Current for Indicated Heat Dissipation (In)
480 A
Static heat dissipation, independent of Pvs current
140 W
10.2.2 Corrosion Resistance
The requirements of the product standard are met.
10.2.3.1 Verification Resistance Thermal stability of enclosures
The requirements of the product standard are met.
10.2.3.2 Verification Resistance Insulating Materials Normal Heat
The requirements of the product standard are met.
10.2.3.3 Resist. mat. isol. with heat excep. as a result of internal electrical effects
The requirements of the product standard are met.
10.2.4 UV Resistance
The requirements of the product standard are met.
10.2.5 Lifting
Not applicable because the entire apparatus must be evaluated.
10.2.6 Impact test
Not applicable because the entire apparatus must be evaluated.
10.2.7 Registrations
The requirements of the product standard are met.
10.3 Degree of Protection of Assemblies
Not applicable because the entire apparatus must be evaluated.
10.4 Isolation Distances and Creepage Lines
The requirements of the product standard are met.
10.5 Protection Against Electric Shock
Not applicable because the entire apparatus must be evaluated.
10.6 Mounting Hardware
Not applicable because the entire apparatus must be evaluated.
10.7 Electrical Circuits and Internal Connections
Is the responsibility of the panel builder.
10.8 Connections for externally routed conductors
Is the responsibility of the panel builder.
10.9.2 Withstand voltage at power frequency
Is the responsibility of the panel builder.
10.9.3 Impact Resistance Voltage
Is the responsibility of the panel builder.
10.9.4 Testing of Insulating Enclosures
Is the responsibility of the panel builder.
10.10 Warm-up
The panel builder is responsible for the calculations of the temperature increase. Eaton will provide heat dissipation data for the devices.
10.11 Short-Circuit Resistance
Is the responsibility of the panel builder. The specifications for the equipment must be followed.
10.12 Electromagnetic Compatibility
Is the responsibility of the panel builder. The specifications for the equipment must be followed.
10.13 Mechanical Operation
At the device level, the requirements are met as long as the instructions in the assembly instructions (IL) are taken into account.

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.