S711-34320DC EP-401545 EATON ELECTRIC S711 Soft Starter (24VDC)

S711-34320DC

EP-401545

EP-401545

EATON-MOELLER

S711 Soft Starter (24VDC)

Eaton S711 Soft Starter, 320, A, 200 - 575 V AC, Us = 24 V DC, with control unit, size 4, IP00

More details


High Performance Soft Starters

Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total: $3,991.13
Unit price: $3,991.13
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



General Specification

Product Name
Eaton S711 Soft Starter
Catalogue number
EP-401545
Product Length/Depth
545 mm
Product height
204 mm
Product Width
222 mm
Product Weight
19.63 kg
Certificate(s)
CE
RCM
IEC/EN 60947-4-2
CUL
UL
UL Category Control No.: NMFT
UL Category Control No.: NMFT7
UL File No.: E251034
UL 60947-4-2
EAN
4015082970857
Model Code
S711-34320DC

Features & Functions

Fault memory
1000 errors
Equipment:
Display
Motor overload protection
Internal bridging
Features
one direction of rotation
Torque Control
DC brake
Soft brake
Forward and backward movement
Interfaces
Modbus RTU (built-in)
Bluetooth (built-in)

General information

Class
Adjustable (5,10,15,20,30)
Connection to SmartWire-DT
Yes
Degree of protection
IP00
NEMA sonsitge
Frame size
FS4
Mains voltage - min.
170 V
Mains voltage - max.
632.5 V
Degree of contamination
3
Radio interference class
Class A (IEC 60947-4-2)
Rated Surge Voltage Strength (Uimp)
6000 V
Starting class
CLASS 20 (heavy start 3 x Iₑ for 45 s)
CLASS 10 (star-delta replacement)
CLASS 30 (6 x Iₑ for 30 s)
Rated Insulation Voltage (Ui)
600 V
Suitable for
Branch circuits, not as BCPD, (UL/cUL)
Type
Soft starter for three-phase loads, with control unit and pump algorithm, DC brake, soft brake, jog, Bluetooth
Voltage type
DC

Ambient conditions, mechanical

Installation position
any
Shock resistance
15 g, Mechanical

Climatic environmental conditions

Altitude
Max 4000 m (Above 1000 m for detailed derating use S711 Select Software)
Ambient Operating Temperature - min.
-25 °C
Ambient operating temperature - max.
60 °C
Ambient temperature storage - min.
-40 °C
Ambient temperature storage - max.
70 °C
Climate resistance
Relative humidity: 5% to 95%

Main conducting paths

Kickstart
600% (inrush current)
Max. 2000 ms (kick-start duration)
Overload cycle
AC-53b: 3.5 - 20:580
Rated Operating Current (le) at AC-53
320 A
Rated operating current (le) at AC-53, in-delta
480 A
Rated operating voltage (Ue) - min.
200 V
Rated operating voltage (Ue) - max.
575 V
Rated operating voltage (Ue) at AC - max.
575 V
Rated Data Short Circuit Protection
400NHG3B or NZMH3-A4008T, Mapping Type 1, Main Live Paths
170M6008, Assignment type "2", Main live paths
Mains frequency
50/60 Hz, fLN, Main Circuit
Nominal voltage - max.
575 V

Motor rating

Assigned motor power at 200/208 V, 60 Hz, 3-phase
100 HP
Assigned motor power at 220/230V, 60Hz, 3-phase
100 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase
250 HP
Assigned motor power in-delta at 220/230V 60Hz
150 HP
Assigned motor power in-delta at 460/480V 60Hz
350 HP
Assigned motor power in-delta at 575/600V 60Hz
450 HP
Rated operating power at 220/230 V, 50 Hz
90 kW
Rated operating power at 400 V, 50 Hz
160 kW
Rated operating power at 500 V, 50 Hz
220 kW
Rated operating power in-delta at 220/230 V, 50 Hz
150 kW
Rated operating power in-delta at 400 V, 50 Hz
250 kW
Rated operating power in-delta at 500 V, 50 Hz
315 kW
Rated power three-phase motor, standard circuit, at 230 V
90 kW
Rated power three-phase motor, standard circuit, at 400 V
160 kW
Rated power three-phase motor, internal delta, at 230 V
150 kW
Rated power three-phase motor, internal delta, at 400 V
250 kW

Terminal capacities

Connection cross-sections (fine-stranded with ferrule)
1 x (185 - 400) mm², main conductor
1 x (1 - 2.5) mm², control power lines
Connection cross-sections (single-stranded)
1 x (185 - 400) mm², main conductor
1 x (1 - 2.5) mm², control power lines
Connection cross-sections (single/multi-strand, AWG)
1 x (350 - 750), main conductor
1 x (28 - 12), Control Power Lines
Connection cross-sections (multi-stranded)
1 x (185 - 400) mm², main conductor
1 x (1 - 2.5) mm², control power lines
Screwdriver size
17 mm M10, Connection Screw, Main Conductor
0.6 x 3.5 mm or PH0, clamping screws, control power lines
Tightening torque
0.5 Nm, screw terminals, control power lines
40 Nm, main conductor

Control circuit

Power Consumption
2800 mA, Control Circuit, Digital Inputs
Drop Voltage
0 - 16 V, DC actuated
Tightening tension
19.2 - 28.8 V DC
Rated control supply voltage (Us) at DC - min.
24 VDC
Rated control supply voltage (Us) at DC - max.
24 VDC

Input/Output

Number of outputs
3 relay outputs (1 fixed, 2 programmable)
Output voltage
250 V AC (relay outputs)
Protection
Optional hood for finger and back of the hand safe, touch protection
Rated Control Voltage (Uc)
24 V DC (-20%/+20%)
Rated operating current (le) at AC-11
3 A

Soft start function

Application
  • 3-phase motors: Yes
  • Soft start of three-phase asynchronous motors
Delay Time
0 - 180 s, soft start function, ramp time; 0 - 240 s, soft-stop function, stop times
Rise/ramp-up time
180 s
Starting span
Max. 600% FLA, Min. 100% FLA. Soft start function

Design verification

Device power dissipation, current-dependent pvid
1440 W
Power Dissipation Capacitance Pdiss
0 W
Power dissipation per pole, current-dependent, Pvid
0 W
Rated Operating Current for Power Dissipation (In)
320 A
Static power dissipation, power-independent PVS
140 W
10.2.2 Corrosion Resistance
The requirements of the product standard are met.
10.2.3.1 Thermal Resistance of Sheathing
The requirements of the product standard are met.
10.2.3.2 Resistance of insulating materials ordinary heat
The requirements of the product standard are met.
10.2.3.3 Resistance Insulating materials abnormal. Heat/fire through int. electr. Impact.
The requirements of the product standard are met.
10.2.4 Resistance to UV radiation
The requirements of the product standard are met.
10.2.5 Lifting
Not applicable, as the entire switchgear needs to be evaluated.
10.2.6 Impact Test
Not applicable, as the entire switchgear needs to be evaluated.
10.2.7 Labels
The requirements of the product standard are met.
10.3 Protection class of assemblies
Not applicable, as the entire switchgear needs to be evaluated.
10.4 Clearance and creepage distances
The requirements of the product standard are met.
10.5 Protection against electric shock
Not applicable, as the entire switchgear needs to be evaluated.
10.6 Installation of equipment
Not applicable, as the entire switchgear needs to be evaluated.
10.7 Internal Circuits and Connections
Is the responsibility of the switchgear manufacturer.
10.8 Connections for conductors inserted from the outside
Is the responsibility of the switchgear manufacturer.
10.9.2 Operating Frequency Dielectric Strength
Is the responsibility of the switchgear manufacturer.
10.9.3 Surge Resistance
Is the responsibility of the switchgear manufacturer.
10.9.4 Testing of insulating material coatings
Is the responsibility of the switchgear manufacturer.
10.10 Heating
The heating calculation is the responsibility of the switchgear manufacturer. Eaton provides power dissipation data of the devices.
10.11 Short-circuit resistance
Is the responsibility of the switchgear manufacturer. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the responsibility of the switchgear manufacturer. The specifications for the switchgear must be observed.
10.13 Mechanical Function
The requirements are met for the device, provided that the information in the assembly instructions (IL) are observed.

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.