ANUNCIAR

S711-34075DC EP-401538 EATON ELECTRIC S711 Soft Starter (24VDC)

S711-34075DC

EP-401538

EP-401538

EATON-MOELLER

S711 Soft Starter (24VDC)

Eaton S711 soft starter, 75 A, 200 - 575 V AC, Us= 24 V DC, with control unit, Frame size 2, IP20

More details


High Performance Soft Starters

Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total: $1,205.39
Unit price: $1,205.39
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



General specifications

Product name
Eaton S711 Soft Starters
Catalogue code
EP-401538
Ean
4015082971106
Product length/depth
281 mm
Product height
190 mm
Product width
128 mm
Product weight
5.1 kg
Certification(s)
Ec
RCM
IEC/EN 60947-4-2
CUL
UL
UL Category Control No.: NMFT
UL Category Control No.: NMFT7
UL File No.: E251034
UL 60947-4-2
Model code
S711-34075DC

Features & Functions

Faulty memory
1000 failures
Equipped with:
Display
Motor overload protection
Internal bypass
Functions
Single direction
Torque control
DC Brake
Soft stop
Forward and reverse in jog mode
Interfaces
Modbus RTU (integrated)
Bluetooth (built-in)

General information

Class
Adjustable (5,10,15,20,30)
Connection with SmartWire-DT
no
Degree of protection
Ip20
NEMA 1
size
FS2
Mains voltage - max
170 V
Mains voltage - max
632.5 V
Degree of pollution
3
Radio Jamming Class
Class A (IEC 60947-4-2)
Rated impulse sealing voltage (Uimp)
6000 V
Boot Class
CLASS 20 (3 x Iₑ heavy duty cranking cycle for 45 s)
CLASS 10 (star-delta substitution)
CLASS 30 (6 x Iₑ for 30 s)
Rated insulation voltage (Ui)
600 V
Suitable for
Branch circuits, not like BCPD, (UL/cUL)
type
Softstarter for three-phase loads, with control unit and pump algorithm, DC Brake, Soft Stop, Jog, Bluetooth
Voltage type
DC

Ambient conditions, mechanical

Mounting position
As needed
Impact resistance
15 g, mechanical

Climatic environmental conditions

Altitude
Max 4000 m (Above 1000 m for detailed derating use S711 Select Software)
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
60 °C
Storage ambient temperature - min
-40 °C
Storage ambient temperature - max
70 °C
Climate suitability
Relative humidity from 5 to 95%

Main conducting paths

Startup
600% (Kickstart current)
Max. 2000 ms (kickstart duration)
Overload Cycle
AC-53b: 3.5-20:340
Rated operating current (le) at AC-53
75 A
Operating current rating (Ie) at AC-53, in-delta
112.5 A
Rated Operating Voltage (Ue) - min
200 V
Rated Operating Voltage (Ue) - max
575 V
Rated Operating Voltage (Ue), AC - max
575 V
Short-circuit protection class
100NHG00B or NZMH2-A160-BT, Coordination Type "1", Main Conductive Parts
170M3013, Type "2" Coordination, Main Conductive Parts
Power Frequency
50/60 Hz, fLN, Main Circuit
Rated voltage - max
575 V

Motor rating

Motor power assigned to 200/208 V, 60 Hz, three-phase
20 HP
Motor power assigned to 220/230 V, 60 Hz, three-phase
25 HP
Motor power assigned to 460/480 V, 60 Hz, three-phase
50 HP
In-delta assigned motor power at 220/230 V, 60 Hz
40 HP
In-delta assigned motor power at 460/480 V, 60 Hz
75 HP
In-delta assigned motor power at 575/600 V, 60 Hz
100 HP
Rated operating power at 220/230 V, 50 Hz
22 kW
Rated operating power at 400 V, 50 Hz
37 kW
Operating power rating at 500 V, 50 Hz
55 kW
In-delta rated operating power at 220/230 V, 50 Hz
30 kW
In-delta rated operating power at 400 V, 50 Hz
55 kW
In-delta rated operating power at 500 V, 50 Hz
75 kW
Three-phase motor rated power, in-line, 230 V
22 kW
Three-phase motor rated power, in-line, 400 V
37 kW
Three-phase motor rated power, in-delta, 230 V
30 kW
Three-phase motor rated power, in-delta, 400 V
55 kW

Terminal capacities

Terminal capacity (flexible with ferrule)
1 x (6 - 70) mm², main conductors
1 x (1 - 2.5) mm², Control current conductors
Terminal capacity (solid)
1 x (6 - 70) mm², main conductors
1 x (1 - 2.5) mm², Control current conductors
Terminal capacity (solid/braided AWG)
1 x (10 - 2/0), main conductors
1x (28 - 12) , Control current conductors
Connecting sections (stranded)
1 x (6 - 70) mm², main conductors
1 x (1 - 2.5) mm², Control current conductors
Screwdriver size
1 x 7mm or T20, End screw, main leads
0.6 x 3.5 mm or PH0, Terminal screws, Control current conductors
Tightening torque
0.5 Nm, screw terminals, control current conductors
4 Nm, Main Conductors

Control circuit

Current consumption
2800 mA, Control circuit, Digital inputs
Drop-out voltage
0 - 16 V, DC control
Excitation voltage
19.2 - 28.8 V DC
Rated Control Supply Voltage (Us), DC - min
24 VDC
Rated Control Supply Voltage (Us), DC - Max
24 VDC

Input/Output

Number of outputs
3 relay outputs (1 fixed, 2 programmable)
Output voltage
250 V AC (relay outputs)
Protection
Protection against contact with fingers and back of the hand, Protection against direct contact
Rated Control Voltage (Uc)
24 V DC (-20 %/+20 %)
Rated operating current (le) at AC-11
3 A

Soft start function

Application
  • Three phase motors: Yes
  • Soft start of three-phase asynchronous motors
Lag time
0 - 180 s, Soft Start Function, Ramp Times; 0 - 240 s, Soft stop function, Standstill times
Start/ramp time
180 s
Start-up voltage
Max. 600% FLA, Min. 100% FLA, Soft start function

Design verification

Equipment dissipation, dependent on Pvid current
337.5 W
Pdiss Dissipation Capacity
0 W
Per-pole dissipation, dependent on Pvid current
0 W
Rated operating current for specific dissipation (In)
75 A
Static dissipation, not dependent on PVS current
50 W
10.2.2 Corrosion resistance
Meets the requirements of the product standard.
10.2.3.1 Thermal stability check of enclosures
Meets the requirements of the product standard.
10.2.3.2 Verification of the resistance of insulating materials to normal heat
Meets the requirements of the product standard.
10.2.3.3 Resist. mat. isol. with fire/abnormal heat due to the electrical effect. internal
Meets the requirements of the product standard.
10.2.4 Resistance to ultraviolet (UV) radiation
Meets the requirements of the product standard.
10.2.5 Lifting
Not applicable, as the entire electrical panel must be assessed.
10.2.6 Mechanical Impact
Not applicable, as the entire electrical panel must be assessed.
10.2.7 Registrations
Meets the requirements of the product standard.
10.3 Degree of protection of component assemblies
Not applicable, as the entire electrical panel must be assessed.
10.4 Surface insulation distances
Meets the requirements of the product standard.
10.5 Electrocution Protection
Not applicable, as the entire electrical panel must be assessed.
10.6 Embedding Components and Switching Devices
Not applicable, as the entire electrical panel must be assessed.
10.7 Internal Electrical Connections and Circuits
It is the responsibility of the manufacturer of the electrical control panel.
10.8 Connections for external conductors
It is the responsibility of the manufacturer of the electrical control panel.
10.9.2 Power-Frequency Electrical Rigidity
It is the responsibility of the manufacturer of the electrical control panel.
10.9.3 Impulse withstand voltage
It is the responsibility of the manufacturer of the electrical control panel.
10.9.4 Insulation Material Enclosures Test
It is the responsibility of the manufacturer of the electrical control panel.
10.10 Heating
The calculation of the overtemperature is the responsibility of the manufacturer of the electrical panel. Eaton will provide dissipation data for the devices.
10.11 Short-circuit resistance
It is the responsibility of the manufacturer of the electrical control panel. The specifications for the electrical panel must be observed.
10.12 Electromagnetic Compatibility
It is the responsibility of the manufacturer of the electrical control panel. The specifications for the electrical panel must be observed.
10.13 Mechanical function
The appliance meets the requirements by complying with the assembly instructions (IL).

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.