FI-80/4/03-S/B 281024 EATON ELECTRIC Residual current circuit-breaker, 80A, 4p, 3A, B-Char View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

FI-80/4/03-S/B 281024 EATON ELECTRIC Residual current circuit-breaker, 80A, 4p, 3A, B-Char

FI-80/4/03-S/B

281024

EATON-MOELLER

Residual current circuit-breaker, 80A, 4p, 3A, B-Char

More details


Modular Switchgear – Industrial

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Delivery program
Basic function
Residual current circuit-breakers
Number of poles
4 pole
Rated current
In A 80
Rated short-circuit strength
Icn kA 10
Rated fault current
IΔN A 0.3
Type
Type S/B
Tripping
s… selective switch off
Product range
FI
Sensitivity
All current sensitive
Impulse withstand current
surge-proof 5 kA
Technical data
Electrical
Standards
IEC/EN 61008
Tripping
s… selective switch off
Rated operating voltage
Ue V AC 230/400
Limit values of the operating voltage
V AC 184 … 440
Rated frequency
f Hz 50
Rated fault currents
IΔn mA 30, 100, 300, 500
Rated non-tripping current
IΔno 0.5 x I∆n
Rated fault switching capacity
Rated fault switching capacity
IΔm A In = 40 A: 500
In = 63 A: 630
In = 80 A: 800
In = 100 A: 1000
In= 125 A: 1250
Sensitivity
Pulsed current and AC/DC
Rated switching capacity
Icn kA 10
Rated current
Ie A 80
Rated impulse withstand voltage
Uimp kV 4
Maximum max. as short-circuit protective device
A gL In < 80 A: 100
In= 80 A: 125
In= 125 A: 125
Lifespan
S
Electrical
Operations > 2000
Mechanical
Operations > 5000
Mechanical
Standard front dimension
mm 45
Enclosure height
mm 85
Terminal protection
Protection against electric shock to IEC 536
Mounting width
mm 70 (4 space unit)
Mounting
Top-hat rail IEC/EN 60715
Degree of protection
Integrated
IP40
Terminals top and bottom
Twin-purpose terminals
Terminal capacities
mm2
Solid
mm2 1.5 - 50; 2 x (1.5 - 16)
Stranded
mm2 1.5 - 50; 2 x (1.5 - 16)
flexible
mm2 1.5 - 50; 2 x (1.5 - 16)
Thickness of busbar material
mm 0.8 … 2
Admissible ambient temperature range
°C -25 … +40
Climatic proofing
IEC/EN 61008
Technical data ETIM 7.0(Show features)(Hide features)
Circuit breakers and fuses (EG000020) / Residual current circuit breaker (RCCB) (EC000003)
Electric engineering, automation, process control engineering / Electrical installation, device / Residual current protection system / Residual current circuit breaker (RCCB) ([email protected] [AAB906014])
Number of poles
4
Rated voltage
V 400
Rated current
A 80
Rated fault current
mA 300
Rated insulation voltage Ui
V 400
Rated impulse withstand voltage Uimp
kV 4
Mounting method
DIN rail
Leakage current type
B
Selective protection
Yes
Short-time delayed tripping
Yes
Short-circuit breaking capacity (Icw)
kA 10
Surge current capacity
kA 5
Frequency
50 Hz
Additional equipment possible
Yes
With interlocking device
Yes
Degree of protection (IP)
IP20
Width in number of modular spacings
4
Built-in depth
mm 69.5
Ambient temperature during operating
°C -25 - 55
Pollution degree
2
Connectable conductor cross section multi-wired
mm² 1.5 - 16
Connectable conductor cross section solid-core
mm² 1.5 - 35

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.