FI-80/4/03-S/B
281024
EATON-MOELLER
1
Residual current circuit-breaker, 80A, 4p, 3A, B-Char
Modular Switchgear – Industrial
* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Basic function | Residual current circuit-breakers | ||
Number of poles | 4 pole | ||
Rated current | In | A | 80 |
Rated short-circuit strength | Icn | kA | 10 |
Rated fault current | IΔN | A | 0.3 |
Type | Type S/B | ||
Tripping | s… | selective switch off | |
Product range | FI | ||
Sensitivity | All current sensitive | ||
Impulse withstand current | surge-proof 5 kA |
Electrical | |||
Standards | IEC/EN 61008 | ||
Tripping | s… | selective switch off | |
Rated operating voltage | Ue | V AC | 230/400 |
Limit values of the operating voltage | V AC | 184 … 440 | |
Rated frequency | f | Hz | 50 |
Rated fault currents | IΔn | mA | 30, 100, 300, 500 |
Rated non-tripping current | IΔno | 0.5 x I∆n | |
Rated fault switching capacity | |||
Rated fault switching capacity | IΔm | A | In = 40 A: 500 In = 63 A: 630 In = 80 A: 800 In = 100 A: 1000 In= 125 A: 1250 |
Sensitivity | Pulsed current and AC/DC | ||
Rated switching capacity | Icn | kA | 10 |
Rated current | Ie | A | 80 |
Rated impulse withstand voltage | Uimp | kV | 4 |
Maximum max. as short-circuit protective device | A gL | In < 80 A: 100 In= 80 A: 125 In= 125 A: 125 | |
Lifespan | S | ||
Electrical | Operations | > 2000 | |
Mechanical | Operations | > 5000 | |
Mechanical | |||
Standard front dimension | mm | 45 | |
Enclosure height | mm | 85 | |
Terminal protection | Protection against electric shock to IEC 536 | ||
Mounting width | mm | 70 (4 space unit) | |
Mounting | Top-hat rail IEC/EN 60715 | ||
Degree of protection | |||
Integrated | IP40 | ||
Terminals top and bottom | Twin-purpose terminals | ||
Terminal capacities | mm2 | ||
Solid | mm2 | 1.5 - 50; 2 x (1.5 - 16) | |
Stranded | mm2 | 1.5 - 50; 2 x (1.5 - 16) | |
flexible | mm2 | 1.5 - 50; 2 x (1.5 - 16) | |
Thickness of busbar material | mm | 0.8 … 2 | |
Admissible ambient temperature range | °C | -25 … +40 | |
Climatic proofing | IEC/EN 61008 |
Circuit breakers and fuses (EG000020) / Residual current circuit breaker (RCCB) (EC000003) | |||
Electric engineering, automation, process control engineering / Electrical installation, device / Residual current protection system / Residual current circuit breaker (RCCB) ([email protected] [AAB906014]) | |||
Number of poles | 4 | ||
Rated voltage | V | 400 | |
Rated current | A | 80 | |
Rated fault current | mA | 300 | |
Rated insulation voltage Ui | V | 400 | |
Rated impulse withstand voltage Uimp | kV | 4 | |
Mounting method | DIN rail | ||
Leakage current type | B | ||
Selective protection | Yes | ||
Short-time delayed tripping | Yes | ||
Short-circuit breaking capacity (Icw) | kA | 10 | |
Surge current capacity | kA | 5 | |
Frequency | 50 Hz | ||
Additional equipment possible | Yes | ||
With interlocking device | Yes | ||
Degree of protection (IP) | IP20 | ||
Width in number of modular spacings | 4 | ||
Built-in depth | mm | 69.5 | |
Ambient temperature during operating | °C | -25 - 55 | |
Pollution degree | 2 | ||
Connectable conductor cross section multi-wired | mm² | 1.5 - 16 | |
Connectable conductor cross section solid-core | mm² | 1.5 - 35 |
Title: | Size: | Type: |
---|---|---|
PDF EATON XEFFECT SWITCHGEAR RANGE EN.pdf | 8 Mbytes | |
FI-80/4/03-S/B 281024 281024.pdf | 198 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.