PKDM-16/1N/C/03-A 248794 EATON ELECTRIC RCD/MCB, 16A, 300mA, miniature circuit-breaker trip curve C, 1pole+N.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PKDM-16/1N/C/03-A 248794 EATON ELECTRIC RCD/MCB, 16A, 300mA, miniature circuit-breaker trip curve C, 1pole+N..

PKDM-16/1N/C/03-A

248794

EATON-MOELLER

RCD/MCB, 16A, 300mA, miniature circuit-breaker trip curve C, 1pole+N, residual current circuit-breaker trip characteristic: A

More details


Modular Switchgear – Tertiary and Differential

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



RCD/MCB, 16A, 300mA, miniature circuit-breaker trip curve C, 1pole+N, residual current circuit-breaker trip characteristic: A
RCBO (residual-current circuit breaker with overload protection) PKDM, 1 pole+N, Tripping characteristic: C, Rated current In: 16 A, Rated switching capacity according to IEC/EN 61009: 10 kA, Rated fault current IΔN: 0.3 A, Pulse-current sensitive, Partly surge-proof 250 A, Switchgear for residential and commercial applications

Delivery program

Basic function
Combined RCD/MCB devices
Number of poles
1 pole+N
Tripping characteristic
C
Application
Switchgear for residential and commercial applications
Rated current [In]
16 A
Rated switching capacity according to IEC/EN 61009
10 kA
Rated fault current [IΔN]
0.3 A
Type
Type A
Tripping
non-delayed s…
Product range
PKDM
Sensitivity
Pulse-current sensitive
Impulse withstand current
Partly surge-proof 250 A

Technical data

Electrical
Sensitivity
Pulse-current sensitive

Design verification as per IEC/EN 61439

Rated operational current for specified heat dissipation [In]
16 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
3.6 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+40 °C

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / Earth leakage circuit breaker (EC000905)
Electric engineering, automation, process control engineering / Electrical installation, device / Residual current protection system / MCB/RCCB combination ([email protected] [AFZ810015])
Number of poles (total)
2
Number of protected poles
1
Rated voltage
230 V
Rated insulation voltage Ui
V
Rated impulse withstand voltage Uimp
kV
Rated current
16 A
Rated fault current
0.3 A
Leakage current type
A
Current limiting class
3
Rated short-circuit breaking capacity acc. EN 61009
kA
Rated short-circuit breaking capacity IEC 60947-2
0 kA
Rated short-circuit breaking capacity Icn acc. EN 61009-1
kA
Disconnection characteristic
Surge current capacity
0.25 kA
Voltage type
AC
Frequency
50 Hz
Release characteristic
C
Concurrently switching N-neutral
Yes
With interlocking device
Over voltage category
3
Pollution degree
2
Ambient temperature during operating
°C
Width in number of modular spacings
2
Built-in depth
69.5 mm
Suitable for flush-mounted installation
No
Anti-nuisance tripping version
No
Degree of protection (IP)
IP20
Connectable conductor cross section solid-core
mm²
Connectable conductor cross section multi-wired
mm²

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.