Eaton Moeller® series P1 Main switch, 40 A, surface mounting, 3 pole, Emergency switching off function, With red rotary handle and yellow locking ring, Lockable in the 0 (Off) position, hard knockout version, with assembly sheet screen
Main switch, P1, Rated uninterrupted current (Iu): 40 A, Functions: Emergency switching off function, Interlockable, Fitted with: Red rotary handle and yellow locking ring, Assembly sheet screen, Auxiliary contact, Mounting method: Surface mounting, Number of poles: Three-pole, Locking facility: Lockable in the 0 (Off) position, Degree of Protection: IP65
Low-voltage industrial components > Switch disconnector
Disconnectors and Cam Switches
Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Product Name | Eaton Moeller® series P1 Main switch |
| Catalog Number | 199917 |
| Model Code | P1-40/I2H/MBS/SVB |
| EAN | 4015082953430 |
| Product Length/Depth | 116 mm |
| Product Height | 181 mm |
| Product Width | 100 mm |
| Product Weight | 0.656 kg |
| Compliances | UKCA CE |
| Certifications | IEC/EN 60947 IEC/EN 60947-3 IEC/EN 60204 |
| Catalog Notes | Rated Short-time Withstand Current (Icw) for a time of 1 second |
| Enclosure material | Polycarbonate |
| Features | Version as main switch Version as maintenance-/service switch Version as emergency stop installation |
| Fitted with: | Red rotary handle and yellow locking ring Assembly sheet screen Auxiliary contact |
| Functions | Emergency switching off function Interlockable |
| Locking facility | Lockable in the 0 (Off) position |
| Number of poles | 3 |
| Degree of protection | IP65 |
| Degree of protection (front side) | IP65 |
| Lifespan, mechanical | 300,000 Operations |
| Mounting method | Surface mounting |
| Mounting position | As required |
| Operating frequency | 50 Operations/h |
| Overvoltage category | III |
| Pollution degree | 3 |
| Product Category | Main switch |
| Product Category | Main switch |
| Rated impulse withstand voltage (Uimp) | 6000 V AC |
| Safe isolation | 440 V AC, Between the contacts, According to EN 61140 |
| Shock resistance | 15 g, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 20 ms |
| Switching angle | 90 ° |
| Ambient operating temperature - min | -25 °C |
| Ambient operating temperature - max | 40 °C |
| Ambient operating temperature (enclosed) - min | -20 °C |
| Ambient operating temperature (enclosed) - max | 40 °C |
| Climatic proofing | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
| Terminal capacity | 1 x (1 - 4) mm², flexible with ferrules to DIN 46228 2 x (1 - 4) mm², flexible with ferrules to DIN 46228 1 x 10 mm² with fork terminal 2 x 10 mm² with fork terminal |
| Screw size | M4, Terminal screw |
| Tightening torque | 1.6 Nm, Screw terminals |
| Rated breaking capacity at 400/415 V (cos phi to IEC 60947-3) | 290 kA |
| Rated breaking capacity at 660/690 V (cos phi to IEC 60947-3) | 130 kA |
| Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V | 30 A |
| Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V | 30 A |
| Rated operational current (Ie) at AC-3, 660 V, 690 V | 17 A |
| Rated operational current (Ie) at AC-21, 440 V | 40 A |
| Rated operational current (Ie) at AC-23A, 230 V | 40 A |
| Rated operational current (Ie) at AC-23A, 400 V, 415 V | 40 A |
| Rated operational current (Ie) at AC-23A, 690 V | 20 A |
| Rated operational power at AC-3, 380/400 V, 50 Hz | 15 kW |
| Rated operational power at AC-3, 415 V, 50 Hz | 15 kW |
| Rated operational power at AC-3, 690 V, 50 Hz | 15 kW |
| Rated operational power at AC-23A, 220/230 V, 50 Hz | 11 kW |
| Rated operational power at AC-23A, 400 V, 50 Hz | 22 kW |
| Rated operational power at AC-23A, 690 V, 50 Hz | 18.5 kW |
| Rated operational voltage (Ue) at AC - max | 690 V |
| Rated uninterrupted current (Iu) | 40 A |
| Uninterrupted current | Rated uninterrupted current Iu is specified for max. cross-section. |
| Rated conditional short-circuit current (Iq) | 80 kA |
| Rated short-time withstand current (Icw) | 0.64 kA 640 A, Contacts, 1 second |
| Short-circuit protection rating | 50 A gG/gL, Fuse, Contacts |
| Load rating | 1.3 x Iₑ (with intermittent operation class 12, 60 % duty factor) 1.6 x Iₑ (with intermittent operation class 12, 40 % duty factor) 2 x Iₑ (with intermittent operation class 12, 25 % duty factor) |
| Control circuit reliability | 1 failure per 100,000 switching operations statistically determined, at 24 V DC, 10 mA) |
| Number of auxiliary contacts (change-over contacts) | 0 |
| Number of auxiliary contacts (normally closed contacts) | 0 |
| Number of auxiliary contacts (normally open contacts) | 0 |
| Actuator color | Red |
| Actuator type | Door coupling rotary drive |
| Equipment heat dissipation, current-dependent Pvid | 0 W |
| Heat dissipation capacity Pdiss | 0 W |
| Heat dissipation per pole, current-dependent Pvid | 3.5 W |
| Rated operational current for specified heat dissipation (In) | 40 A |
| Static heat dissipation, non-current-dependent Pvs | 0 W |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | UV resistance only in connection with protective shield. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| Feature Name | Feature Value |
|---|---|
| Version as main switch (EF006981) | Yes |
| Version as maintenance-/service switch (EF006986) | Yes |
| Version as safety switch (EF006985) | No |
| Version as emergency stop installation (EF006959) | Yes |
| Version as reversing switch (EF009408) | No |
| Number of switches (EF005586) | 1 |
| Max. rated operation voltage Ue AC (EF007355) | 690 V |
| Rated operating voltage (EF001435) | 690 V |
| Rated permanent current Iu (EF001389) | 40 A |
| Rated permanent current at AC-23, 400 V (EF011777) | 40 A |
| Rated permanent current at AC-21, 400 V (EF009165) | 40 A |
| Rated operation power at AC-3, 400 V (EF001364) | 15 kW |
| Rated short-time withstand current lcw (EF007050) | 0.64 kA |
| Rated operation power at AC-23, 400 V (EF007027) | 22 kW |
| Switching power at 400 V (EF009166) | 22 kW |
| Conditioned rated short-circuit current Iq (EF001444) | 80 kA |
| Number of poles (EF001391) | 3 |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| Motor drive optional (EF007386) | No |
| Motor drive integrated (EF006697) | No |
| Voltage release optional (EF007491) | No |
| Device construction (EF008240) | Complete device in housing |
| Suitable for front mounting 4-hole (EF007247) | No |
| Suitable for front mounting centre (EF007248) | No |
| Suitable for distribution board installation (EF007262) | No |
| Suitable for intermediate mounting (EF007264) | No |
| Colour control element (EF007167) | Red |
| Type of control element (EF006976) | Door coupling rotary drive |
| Interlockable (EF006281) | Yes |
| Type of electrical connection of main circuit (EF006819) | Screw connection |
| With pre-assembled cabling (EF016444) | No |
| Degree of protection (IP), front side (EF003118) | IP65 |
| Width (EF000008) | 100 mm |
| Height (EF000040) | 181 mm |
| Depth (EF000049) | 116 mm |
| Title: | Size: | Type: |
|---|---|---|
| PDF EATON SAFE SWITCHING EN.pdf | 935 Kbytes |
|
| PDF CATALOGUE EATON EN .pdf | 38 Mbytes |
|
| P1-40/I2H/MBS/SVB Y7-199917 199917 EN_227872.pdf | 1 Mbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.