Product successfully added to your shopping cart
NZML2-PMX90
189702
EATON-MOELLER
1
NZM2 PXR25 Automatic Int. - Class 1, 90A, 3p Power Reading, Screw Terminal
Circuit-breaker, Motor protection, IEC, Fixed, Electronic release, IEC/EN 60947-4-1, IEC/EN 60947-2, The circuit-breaker fulfills all requirements for AC-3 switching category., R.m.s. value measurement and “thermal memory”, adjustable time delay setting to overcome current peaks tr: 2 – 20 s at 6 x Ir also infinity (without overload releases), All AC-3 rating data applies to direct switching by the circuit-breaker under normal operating conditions . If, for example, a contactor takes over AC-3 switching under normal operating conditions, the full rated uninterrupted current applies to the circuit-breaker, In = Iu., 3 pole, Screw terminal, Rated current = rated uninterrupted current: In = Iu 90 A, Ii = In x … 2 - 14
Low-voltage industrial components > Motor protection circuit-breaker
Circuit Breakers NZM
Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Feature Name | Feature Value |
|---|---|
| Overload release current setting (EF002336) | 36 A |
| Adjustment range undelayed short-circuit release (EF007131) | 180 A |
| With thermal overload protection (EF006233) | Yes |
| Phase failure sensitive (EF007400) | Yes |
| Switch off technique (EF007007) | Electronic |
| Rated operating voltage (EF001435) | 690 V |
| Rated permanent current Iu (EF001389) | 90 A |
| Rated operation power at AC-3, 230 V (EF007025) | 22 kW |
| Rated operation power at AC-3, 400 V (EF001364) | 45 kW |
| Type of electrical connection of main circuit (EF006819) | Screw connection |
| Type of control element (EF006976) | Rocker lever |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| With integrated auxiliary switch (EF001387) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Rated short-circuit breaking capacity Icu at 400 V, AC (EF007049) | 130 kA |
| Degree of protection (IP) (EF005474) | IP20 |
| Height (EF000040) | 149 mm |
| Width (EF000008) | 105 mm |
| Depth (EF000049) | 184 mm |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE EATON EN .pdf | 38 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.