Product successfully added to your shopping cart
PLS6-C6-MW
242675
Y7-242675
EATON-MOELLER
12
Over current switch, 6A, 1p, type C characteristic
PLS6-C6-MW
Eaton Moeller series xPole - PLS6/M MCB. PLS6, 1-pole, tripping characteristic: C, rated current In: 6 A, rated switching capacity IEC/EN 60898-1: 6 kA
Miniature circuit breaker (MCB), PLS6, 1-pole, tripping characteristic: C, rated current In: 6 A, rated switching capacity according to IEC/EN 60898-1: 6 kA, Switchgear for residential and commercial applications
Circuit breakers and fuses > Miniature circuit breaker (MCB)
Residential Switchgear
Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Product Name | Eaton Moeller series xPole - PLS6/M MCB |
| Catalog Number | 242675 |
| Model Code | PLS6-C6-MW |
| EAN | 4015082426750 |
| Product Length/Depth | 85 mm |
| Product Height | 73 mm |
| Product Width | 17.5 mm |
| Product Weight | 0.12 kg |
| Compliances | RoHS conform |
| Certifications | CE |
| Application |
|
| Number of poles | Single-pole |
| Number of poles (total) | 1 |
| Number of poles (protected) | 1 |
| Tripping characteristic | C |
| Release characteristic | C |
| Amperage Rating | 6 A |
| Type |
|
| Voltage type | AC |
| Rated operational voltage (Ue) - max | 230 V |
| Rated insulation voltage (Ui) | 440 V |
| Rated impulse withstand voltage (Uimp) | 4 kV |
| Frequency rating - min | 50 Hz |
| Frequency rating - max | 60 Hz |
| Rated switching capacity (IEC/EN 60898-1) | 6 kA |
| Overvoltage category | III |
| Pollution degree | 2 |
| Width in number of modular spacings | 1 |
| Built-in depth | 70.5 mm |
| Degree of protection | IP20 |
| Connectable conductor cross section (solid-core) - min | 1 mm² |
| Connectable conductor cross section (solid-core) - max | 25 mm² |
| Connectable conductor cross section (multi-wired) - min | 1 mm² |
| Connectable conductor cross section (multi-wired) - max | 25 mm² |
| Rated operational current for specified heat dissipation (In) | 6 A |
| Heat dissipation per pole, current-dependent | 0 W |
| Equipment heat dissipation, current-dependent | 1.5 W |
| Static heat dissipation, non-current-dependent | 0 W |
| Heat dissipation capacity | 0 W |
| Ambient operating temperature - min | -25 °C |
| Ambient operating temperature - max | 75 °C |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| Current limiting class | 3 |
| Features | Additional equipment possible |
| Special features | Ambient temperature hint: a 1 °C increase results in a 0.5% linear reduction of current carrying capacity |
| Used with | Miniature circuit breaker PLS6 |
| Feature Name | Feature Value |
|---|---|
| Built-in depth (EF000218) | 70.5 mm |
| Release characteristic (EF000889) | C |
| Number of poles (total) (EF008618) | 1 |
| Number of protected poles (EF005548) | 1 |
| Rated current (EF000227) | 6 A |
| Rated voltage (EF000228) | 230 V |
| Rated insulation voltage Ui (EF001366) | 440 V |
| Rated impulse withstand voltage Uimp (EF011980) | 4 kV |
| Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V (EF009556) | 6 kA |
| Voltage type (EF000187) | AC |
| Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V (EF009555) | 6 kA |
| Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V (EF009557) | 0 kA |
| Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V (EF009558) | 0 kA |
| Frequency (EF000416) | 50 Hz |
| Power loss (EF005387) | 1.2 W |
| Current limiting class (EF002568) | 3 |
| Flush-mounted installation (EF007517) | No |
| Concurrently switching neutral conductor (EF005997) | No |
| Over voltage category (EF002569) | 3 |
| Pollution degree (EF002570) | 2 |
| Additional equipment possible (EF008148) | Yes |
| Width in number of modular spacings (EF002950) | 1 |
| Degree of protection (IP) (EF005474) | IP20 |
| Ambient temperature during operating (EF007515) | -25 °C |
| Connectable conductor cross section multi-wired (EF007343) | 1 mm² |
| Connectable conductor cross section solid-core (EF007337) | 1 mm² |
| Explosion-proof (EF004663) | No |
| Title: | Size: | Type: |
|---|---|---|
| PDF EATON XEFFECT SWITCHGEAR RANGE EN.pdf | 8 Mbytes |
|
| PDF CATALOGUE EATON EN .pdf | 38 Mbytes |
|
| PLS6-C6-MW Y7-242675 242675 EN_242675.pdf | 80 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.