ANUNCIAR

IZM32H3-V08F-1 EP-500230 Y7-500230 EATON ELECTRIC IZM32H, 3-pole, 800 A, fixed mount

IZM32H3-V08F-1

EP-500230

Y7-500230

EATON-MOELLER

IZM32H, 3-pole, 800 A, fixed mount

IZM32H3-V08F-1 . Circuit-breaker, 3p, 800A, fixed

Circuit-breaker, 3p, 800A, fixed

More details


Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection

Circuit Breakers IZM

Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total: $6,097.15
Unit price: $6,097.15
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



General specifications

Product Name
Eaton IZM32/IN32 circuit-breaker
Catalog Number
EP-500230
Model Code
IZM32H3-V08F-1
EAN
9010653016748
Product Length/Depth
511 mm
Product Height
514 mm
Product Width
492 mm
Product Weight
60.325 kg
Compliances
IEC
IEC/EN 60947

Product specifications

Type
Amperage Rating
800 A
Features
Complete device with protection unit
Motor drive optional
Actuator color
Green
Fitted with:
Switched-off indicator
Frame
IZM32
Pollution degree
3
Rated uninterrupted current (Iu)
800 A
Breaking time
40 ms
Mounting Method
Fixed
Rated impulse withstand voltage (Uimp)
8 kV AC
Utilization category
B
Device construction
Built-in device fixed built-in technique
Direction of incoming supply
As required
Electrical connection type of main circuit
Rail connection
Actuator type
Push button
Adjustment range short-term delayed short-circuit release - max
8000 A
Adjustment range short-term delayed short-circuit release - min
480 A
Adjustment range undelayed short-circuit release - max
12000 A
Adjustment range undelayed short-circuit release - min
1600 A
Ambient operating temperature - max
70 °C
Ambient operating temperature - min
-20 °C
Ambient storage temperature - max
70 °C
Ambient storage temperature - min
-20 °C
Heat dissipation at rated current with fixed mounting
30 W
Number of auxiliary contacts (change-over contacts)
4
Number of auxiliary contacts (normally closed contacts)
0
Number of auxiliary contacts (normally open contacts)
0
Number of standard mechanical operations per hour - max
60
Operating sequence up to 690 V, 50/60 Hz (IEC/EN 60947)
85 kA
Overload release current setting - max
800 A
Overload release current setting - min
320 A
Power of withdrawable switch with cassette
60 W
Rated insulation voltage (Ui)
1000 V
Overvoltage category
III
Weight of cassette version (3-pole)
34 kg
Weight of cassette version (4-pole)
38 kg
Weight of fixed mounting version (3-pole)
68 kg
Weight of fixed mounting version (4-pole)
86 kg
Weight of fixed withdrawable version (3-pole)
80 kg
Weight of fixed withdrawable version (4-pole)
102 kg
Protection
Selective operation
Voltage rating at AC
690 V AC
Number of poles
Three-pole
Degree of protection
IP20
IP41 with door sealing frame
IP55 with protective cover
Closing delay via spring release
30 ms
Position of connection for main current circuit
Back side
Release system
Electronic release
Suitable for
Main conducting paths with 100 kA in IT electrical power networks up to U = 440 V
Rated operating voltage (Ue) - min
690 V
Rated operating voltage (Ue) at AC - max
690 V
Rated short-circuit breaking capacity at 400 V, 50 Hz
100 kA
Rated short-circuit making capacity up to 440 V, 50/60 Hz
220 kA
Rated short-circuit making capacity up to 690 V, 50/60 Hz
187 kA
Rated short-time withstand current (t = 1 s)
85 kA
Rated short-time withstand current at 50/60 Hz (t = 3 s)
65 kA
Rated uninterrupted current (Iu) at 50°C
800 A
Rated uninterrupted current (Iu) at 60°C
800 A
Rated uninterrupted current (Iu) at 70°C
800 A
Terminal capacity (copper bar)
5 mm x 50 mm (2x) for fixed mounting (black)
5 mm x 50 mm (2x) for withdrawable units (black)

ETIM for EP-500230 Low-voltage industrial controls and switchgear (EC000228)
Feature Name Feature Value
Rated permanent current Iu (EF001389) 800 A
Rated voltage (EF003977) 690 V
Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) 100 kA
Overload release current setting (EF002336) 320 A
Adjustment range short-term delayed short-circuit release (EF007129) 480 A
Adjustment range undelayed short-circuit release (EF007131) 1600 A
Device construction (EF008240) Built-in device fixed built-in technique
Integrated earth fault protection (EF007296) No
Type of electrical connection of main circuit (EF006819) Rail connection
Suitable for DIN rail (top hat rail) mounting (EF007250) No
DIN rail (top hat rail) mounting optional (EF008904) No
Number of auxiliary contacts as normally closed contact (EF001377) 0
Number of auxiliary contacts as normally open contact (EF001376) 0
Number of auxiliary contacts as change-over contact (EF003531) 4
With switched-off indicator (EF007006) Yes
With integrated under voltage release (EF001390) No
Number of poles (EF001391) 3
Position of connection for main current circuit (EF006671) Back
Type of control element (EF006976) Push button
Complete device with protection unit (EF008906) Yes
Motor drive integrated (EF006697) No
Motor drive optional (EF007386) Yes
Degree of protection (IP) (EF005474) IP20

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.