ANUNCIAR
EU5E-SWD-4D2R 116383 Y7-116383 EATON ELECTRIC I/O module, SmartWire-DT, 24 V DC, 4DI, 2DO relays, 3A View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

EU5E-SWD-4D2R 116383 Y7-116383 EATON ELECTRIC I/O module, SmartWire-DT, 24 V DC, 4DI, 2DO relays, 3A

EU5E-SWD-4D2R

116383

Y7-116383

EATON-MOELLER

I/O module, SmartWire-DT, 24 V DC, 4DI, 2DO relays, 3A

EU5E-SWD-4D2R

Eaton EU5E SWD I/O module, 24 V DC, 4 digital inputs, 2 digital relay outputs 3 A

More details


PLC's > Fieldbus, decentr. periphery - digital I/O module

Smartwire Darwin

Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total: $175.11
Unit price: $175.11
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



General specifications

Product Name
Eaton EU5E I/O module
Catalog Number
116383
Model Code
EU5E-SWD-4D2R
EAN
4015081161133
Product Length/Depth
102 mm
Product Height
90 mm
Product Width
35 mm
Product Weight
0.1 kg
Certifications
CSA File No.: 2324643
UL File No.: E29184
IEC/EN 61131-2
UL Category Control No.: NKCR
CSA Class No.: 3211-07
CSA
UL
Catalog Notes
uts 250 Vac

Features & Functions

Electric connection type
Flat plug-in connection
Features
Fieldbus connection over separate bus coupler possible
Functions
For connection of digital I/O signals

General

Current consumption
45 mA, SmartWire-DT network
Degree of protection
IP20
Lifespan, electrical
50,000 Operations (at 250 V, AC-1, 4 A)
50,000 Operations (at 250 V, AC-15, 3 A)
200,000 Operations (at 24 V, DC-13, 1 A)
Mounting method
Rail mounting possible
Wall mounting/direct mounting
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Overvoltage category
II
Pollution degree
2
Product category
SmartWire-DT slave
Terminal capacity
0.25 - 1.5 mm² (24 - 16 AWG), flexible with ferrule, Terminal for I/O sensor
0.2 - 1.5 mm² (AWG 24 - 16), solid, Terminal for I/O sensor
Type
Digital modules
Voltage type
AC

Ambient conditions, mechanical

Constant acceleration
1 g, 8.4 - 150 Hz, according to IEC/EN 61131-2, Vibrations
Constant amplitude
3,5 mm, 5 - 8.4 Hz, according to IEC/EN 61131-2, Vibrations
Drop and topple
50 mm Drop height, Drop to IEC/EN 60068-2-31
Height of fall (IEC/EN 60068-2-32) - max
0.3 m
Mounting position
As required
Shock resistance
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts

Climatic environmental conditions

Air pressure
795 - 1080 hPa (operation)
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
55 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
70 °C
Climatic proofing
Damp heat, constant, to IEC 60068-2-3
Dry heat to IEC 60068-2-2
Environmental conditions
Condensation: prevent with appropriate measures
Operating temperature - min
-25 °C
Operating temperature - max
55 °C
Relative humidity
5 - 95 % (non-condensing, IEC/EN 60068-2-30)

Electro magnetic compatibility

Air discharge
8 kV, according to IEC 61131-2, level 3, ESD
Burst impulse
1 kV, Signal cable, according to IEC/EN 61131-2, Level 3
1 kV, SmartWire-DT cable, according to IEC/EN 61131-2, Level 3
2 kV, Supply cable, according to IEC/EN 61131-2, Level 3
Contact discharge
4 kV, according to IEC/EN 61131-2, Level 2, ESD
Electromagnetic fields
3 V/m at 1.4 - 2 GHz (according to IEC/EN 61131-2:2008)
10 V/m at 80 - 1000 MHz (according to IEC/EN 61131-2:2008)
1 V/m at 2.0 - 2.7 GHz (according to IEC/EN 61131-2:2008)
Radiated RFI
10 V (IEC/EN 61131-2:2008, Level 3)
Radio interference class
Class A (EN 55011)
Surge rating
1 kV, Surge I/O cables, Surge (IEC/EN 61131-2:2008, Level 1), EMC

Electrical rating

Input current
4 mA (at 24 V DC, Digital inputs)
Input current at signal 1
4 mA
Output current
3 A
Power loss
1 W
Short-circuit protection
4 A gL/gG, Relay outputs, External
Supply voltage at AC, 50 Hz - min
0 VAC
Supply voltage at AC, 50 Hz - max
0 VAC
Supply voltage at DC - min
0 VDC
Supply voltage at DC - max
28.8 VDC

Communication

Connection to SmartWire-DT
Yes
Connection type
Connection plug: external device plug SWD4-8SF2-5, SmartWire-DT
Plug, 8-pole, SmartWire-DT
Push in terminals, Supply and I/O sensor
Data transfer rate
250 kBit/s, SmartWire-DT
Setting automatically
LED indicator
Status indication of Relay outputs: Yellow LED
Status indication of SmartWire-DT network: Green LED
Status indication of input: Yellow LED
Protocol
Other bus systems
Station
SmartWire-DT slave, SmartWire-DT network

Input/Output

Contact type
N/O contact, Relay output
Drop-out time
2.5 ms
Input delay
< 0.2 ms
Limit value type 1
Low: < 5 V DC
High: > 15 V DC
Load current
Min. 100 mA (at 12 V DC)
Number of inputs (digital)
4
Number of outputs (digital)
2
Output
2 Relay Outputs
Pick-up time
5 ms

Safety

Explosion safety category for dust
None
Explosion safety category for gas
None
Potential isolation
Outputs to SmartWire-DT: yes
Inputs for SmartWire-DT: yes
Output to output: no
Safe isolation
230 V AC, According to EN 50178

Design verification

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
1 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.