XN-GW-DNET 140051 0004520637 EATON ELECTRIC Gateway, DeviceNet, 85 50 225164 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

XN-GW-DNET 140051 0004520637 EATON ELECTRIC Gateway, DeviceNet, 85 50 225164

XN-GW-DNET

140051

0004520637

EATON-MOELLER

Gateway, DeviceNet, 85 50 225164

More details


Remote I / O Modules XION

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



EL-Nummer (Norway)
4520637
Gateway, DeviceNet, 85 50 225164
DeviceNet gateway

Delivery program

Function
Gateways XI/ON
Function
XN gateway without integrated supply
Short Description
supports up to 62 disc-type modules (XN, XNE)
1 x Open Style Connector
Address set with two decimal rotary coding switches
Address range: 0 – 63 (dec.)
Field bus connection
DeviceNet
Service interface
PS/2 socket
Data transfer rate
500 Kbit/s
250 Kbit/s
125 kbit/s
Instructions
The supply module XN-BR-24VDC-D must be mounted immediately next to the gateway to provide the supply for the gateway.
Information about equipment supplied
The delivery package for all gateways includes: 2 x end bracket XN-WEW-32/2-SW, 1 x end plate XN-ABPL

Technical data

General
Standards
EN 61000-6-2
EN 61000-6-4
EN 61131-2
ApprovalsApprovals
CE, cULus
Potential isolation
Yes, through optocoupler
Ambient temperature
0 - +55 °C
Storage [ϑ]
-25 - +85 °C
Operating ambient temperature min.
0 °C
Operating ambient temperature max.
+55 °C
Relative humidity
5 - 95 % (indoor), Level RH-2, no condensation (for storage at 45°C)
Harmful gases
SO2: 10 (rel. humidity < 75%, no condensation)
H2S: 1.0 (rel. humidity < 75 %,no condensation) ppm
Vibration
according to IEC/EN 60068-2-6
Mechanical shock resistance
according to IEC 60068-2-27 g
Continuous shock resistance (IEC/EN 60068-2-29)
According to IEC 60068-2-29
Drop and topple
According to IEC 60068-2-31, free fall according to IEC 60068-2-32
Degree of Protection
IP20
Electromagnetic compatibility (EMC)ESD [Air/contact discharge]
EN 61000-4-2 kV
Electromagnetic compatibility (EMC)Electromagnetic fields [(0.08…1) / (1,4…2) / (2…2,7) GHz ]
EN 61100-4-2 V/m
Electromagnetic compatibility (EMC)Burst
EN 61100-4-4
Electromagnetic compatibility (EMC)Surge
EN 61100-4-5
Electromagnetic compatibility (EMC)Radiated RFI
EN 61100-4-6 V
Electromagnetic compatibility (EMC)Emitted interference (radiated, high frequency) [(30...230 MHz) / (230...1000 MHz)]
EN 55016-2-3 dB
Electromagnetic compatibility (EMC)Voltage fluctuations/voltage dips
EN 61131-2
Electromagnetic compatibility (EMC)Type test
to EN 61131-2
Static heat dissipation, non-current-dependent [Pvs]
2.5 W
Other technical data (sheet catalogue)
Terminations
Rated data
according to VDE 0611 Part 1/8.92/IEC/EN 60947-7-1
Connection design in TOP direction
Spring-loaded/screw terminal
Stripping length
8 mm
Clamping range
max. 0.5 - 2.5 mm2
Connectable conductorsSolid
0.5 - 2.5 mm2
Connectable conductorsFlexible without ferrule
0.5 - 1.5 mm2
Connectable conductorsFlexible with ferrule
0.5 - 1.5 mm2
Gauge pin IEC/EN 60947-1
A1
Networking
Bus
DeviceNet
Bus protocol
DeviceNet
Maximum station configuration
74 cards (XN) of slice design or max. length of station: 1 m
System supply [Usys]
24 /5 V DC
Operational voltage
5 (from bus refreshing module) V DC
Admissible range
4.7-5.3 V DC
Residual ripple
According to EN 61131-2 %
Rated current consumption from module bus [IMB]
≦ 250 mA
Service interface
PS/2 socket
Connection design for field bus
Open style connector
Data transfer rate
125, 250, 500 kBit/s
Data transfer rate setting
through DIP switch
Addressing
2 decimal rotary coding switches
Field bus termination
through DIP switch
Address range
0 - 63 decimal

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
0 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
2.5 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
0 °C
Operating ambient temperature max.
+55 °C
Degree of Protection
IP20
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 4.0

Supply voltage AC 50 Hz
0 - 0 V
Supply voltage AC 60 Hz
0 - 0 V
Supply voltage DC
18 - 30 V
Voltage type of supply voltage
DC
Supporting protocol in-bound for TCP/IP
No
Supporting protocol in-bound for PROFIBUS
No
Supporting protocol in-bound for CAN
No
Supporting protocol in-bound for INTERBUS
No
Supporting protocol in-bound for ASI
No
Supporting protocol in-bound for EIB/KNX
No
Supporting protocol in-bound for MODBUS
No
Supporting protocol in-bound for Data-highway
No
Supporting protocol in-bound for DeviceNet
Yes
Supporting protocol in-bound for SUCONET
No
Supporting protocol in-bound for LON
No
Supporting protocol in-bound for SERCOS
No
Supporting protocol in-bound for PROFINET IO
No
Supporting protocol in-bound for PROFINET CBA
No
Supporting protocol in-bound for Foundation Fieldbus
No
Supporting protocol in-bound for EtherNet/IP
No
Supporting protocol in-bound for AS-Interface Safety at Work
No
Supporting protocol in-bound for DeviceNet Safety
No
Supporting protocol in-bound for INTERBUS-Safety
No
Supporting protocol in-bound for PROFIsafe
No
Supporting protocol in-bound for SafetyBUS p
No
Supporting protocol in-bound for other bus systems
No
Supporting protocol out-bound for TCP/IP
No
Supporting protocol out-bound for PROFIBUS
No
Supporting protocol out-bound for CAN
No
Supporting protocol out-bound for INTERBUS
No
Supporting protocol out-bound for ASI
No
Supporting protocol out-bound for EIB/KNX
No
Supporting protocol out-bound for MODBUS
No
Supporting protocol out-bound for Data-highway
No
Supporting protocol out-bound for DeviceNet
Yes
Supporting protocol out-bound for SUCONET
No
Supporting protocol out-bound for LON
No
Supporting protocol out-bound for SERCOS
No
Supporting protocol out-bound for PROFINET IO
No
Supporting protocol out-bound for PROFINET CBA
No
Supporting protocol out-bound for Foundation Fieldbus
No
Supporting protocol out-bound for EtherNet/IP
No
Supporting protocol out-bound for AS-Interface Safety at Work
No
Supporting protocol out-bound for DeviceNet Safety
No
Supporting protocol out-bound for INTERBUS-Safety
No
Supporting protocol out-bound for PROFIsafe
No
Supporting protocol out-bound for SafetyBUS p
No
Supporting protocol out-bound for other bus systems
No
Radiostandard Bluetooth
No
Radiostandard WLAN 802.11
No
IO link master
No
System accessory
Yes
Degree of protection (IP)
IP20
With potential separation
Yes
Fieldbus connection over separate bus coupler possible
Yes
Rail mounting possible
Yes
Wall mounting/direct mounting
No
Front build in possible
No
Rack-assembly possible
No
Suited for safety functions
No
Safety class according to DIN V 19250
0
Category according to EN 954-1
-
SIL according to IEC 61508
0
SIL according to IEC 62061
0
Performance level acc. to EN ISO 13849-1
-
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
Explosion safety category for gas
None
Explosion safety category for dust
None
Width
50.6 mm
Height
114.8 mm
Depth
74.4 mm

Approvals

Product Standards
UL 508; CSA-C22.2 No. 142; IEC/EN 6113-2; CE marking
UL File No.
E205091
UL Category Control No.
NRAQ, NRAQ7
CSA File No.
UL report applies to both US and Canada
CSA Class No.
2252-01, 2252-81
North America Certification
UL recognized, certified by UL for use in Canada
Specially designed for North America
No
Current Limiting Circuit-Breaker
No
Degree of Protection
IEC: IP20, UL/CSA Type: -

Dimensions

272X008
Notes: The plugs/connectors used depend on the version.
Link to sheet catalogue

Datasheet - PDF

Title: Size: Type:
XN-GW-DNET 0004520637 140051 EN_140051.pdf 236 Kbytes   XN-GW-DNET 0004520637 140051 EN_140051.pdf

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.