DA1-324D3FB-A66N 169162 EATON ELECTRIC PowerXL Drive Series DA1 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DA1-324D3FB-A66N 169162 EATON ELECTRIC PowerXL Drive Series DA1

DA1-324D3FB-A66N

169162

EATON-MOELLER

PowerXL Drive - Series DA1

More details


Home > EATON - MOELLER

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Range of delivery
Range
  Frequency converter
Type identifier
  DA1
Rated voltage of employment
Ue 230 V AC, three-phase
240 V AC, 3-phasig
Output voltage (Ue
UTwo 230 V AC, three-phase
240 V AC, 3-phasig
Mains voltage (50/60Hz)
ULNV200 (-10%) - 240 (+10%)
Rated current job
   
for an overload of 150 %
IeHas4.3
Note
  Rated current of employment at a switching frequency of 4 kHz and an ambient air temperature +40 °C
Note
  Cycle of overload for 60 s every 600 s
Engine power corresponding
   
Note
  For three-phase asynchronous motors tétrapolaires standards, internal cooling and surface area (1500 tr/min)-1at 50 Hz and 1800-1at 60 Hz
Note
  Cycle of overload for 60 s every 600 s
Note
  at 230 V, 50 Hz
150 % Overload
PkW0.75
150 % Overload
IeHas3.2
Note
  under 220 - 240 V, 60 Hz
150 % Overload
PHPOne
150 % Overload
IeHas4.2
Degree of protection
  IP66/NEMA 4X
Interface/field bus (built-in)
  OP-Bus (RS485)/Modbus RTU, CANopen®
Module coupling to field bus (option)
  Ethernet IP
DeviceNet
PROFIBUS
PROFINET
Modbus-TCP
EtherCAT
BACnet/IP
SmartWire-DT
Equipment
  Filter interference suppression
Braking unit
Display bright 7-segment
Size
  FS2
Connection to SmartWire-DT
  with module SmartWire-DT DX-NET-SWD2
Technical characteristics
General
Compliance with standards
  General requirements : IEC/EN 61800-2
Requirements EMC : IEC/EN 61800-3
Safety requirements : IEC/EN 61800-5-1
Certifications
  CE, cUL, UL, c-Tick, Ukr Sepro, EAC
Manufacturing quality
  RoHS, ISO 9001
Climate resilience
ρw%< 95 %, average relative humidity (RH), non-condensing, non-corrosive (EN 50178)
Ambient temperature
   
Service (150 % surcharge).
ϑ°C-10 - +40
Storage
ϑ°C-40 - +60
Level of interference suppression
   
Class interference suppression (EMC)
  C1, C2, C3 ; depends on the length of the connection cable to the motor, the connected load and the environment. If applicable, filters, surge suppressor, external (optional) are necessary.
Environment (EMC)
  1st and 2nd environment
maximum length of motor cable
ImC1 ≤ 1 m
C2 ≤ 5 m
C3 ≤ 25 m
Mounting Position
  Vertical
Altitude of installation
 m0 - 1000 m above sea level
above 1000 m : 1 % derating power 100 m
max. 4000 m
Degree of protection
  IP66/NEMA 4X
Protection against direct contacts
  BGV A3 (VBG4, protection against contact with the fingers and the back of the hand)
Main Circuit
Power
   
Rated voltage of employment
Ue 230 V AC, three-phase
240 V AC, 3-phasig
Mains voltage (50/60Hz)
ULNV200 (-10%) - 240 (+10%)
Input current (overload 150 %)
ILNHas4.5
Power
  Networks of alternating current with the middle point connected to earth
Network frequency
fLNHz50/60
Frequency range
fLNHz48 - 62
Frequency power
  every 30 seconds
Power part
   
Function
  Frequency converters with intermediate circuit dc voltage and inverter IGBT
Overload current (overload 150 %)
ITheHas6.45
Peak current at start-up max. (High Overload)
IH%Two hundred
A note about the peak current at start-up max.
  for 4 seconds
Output voltage (Ue
UTwo 230 V AC, three-phase
240 V AC, 3-phasig
Output frequency
fTwoHz0 - 50/60 (max. 500)
Clock frequency
fPWMkHzSixteen
adjustable 4 - 32 (audible)
Operation
  Command U/f
Speed regulation with slip compensation
Control vector without sensor (SLV)
in option : control-vector with feedback (CLV)
Resolution of the frequency (setpoint)
ΔfHz0.1
Rated current job
   
for an overload of 150 %
IeHas4.3
Note
  Rated current of employment at a switching frequency of 4 kHz and an ambient air temperature +40 °C
Power dissipated
   
Power dissipated under current assigned job
PVW39.75
Performance
η%94.7
Leakage current maximum at the ground (PE) without motor
IPEmy1.73
Equipment
  Filter interference suppression
Braking unit
Display bright 7-segment
Safety function
  STO (Safe Torque Off)
Size
  FS2
Start engine
   
Note
  For three-phase asynchronous motors tétrapolaires standards, internal cooling and surface area (1500 tr/min)-1at 50 Hz and 1800-1at 60 Hz
Note
  Cycle of overload for 60 s every 600 s
Note
  at 230 V, 50 Hz
150 % Overload
PkW0.75
Note
  under 220 - 240 V, 60 Hz
150 % Overload
PHPOne
Maximum permissible length of cable
Imshielded: 100
shielded, with inductance motor: 200
non-shielded: 150
non-armoured, with inductance motor: 300
Apparent power
   
Apparent power in rated service 230 V
SkVA1.71
Apparent power in rated service 240 V
SkVA1.79
Braking function
   
Braking torque Standard
  max. 30 % MN
Braking torque Braking dc
  100 %, adjustable
Braking torque with external braking resistor
  max. 100% of the rated current of job Ie with external braking resistor
External braking resistor min.
RminΩOne hundred
Activation threshold for the braking transistor
UDCV390 V DC
Part command
control voltage external
UcV24 V DC (max. 100 mA)
Voltage setpoint
UsV10 V DC (max. 10 mA)
Analog inputs
  2, configurable 0 - 10 V DC, 0/4 - 20 mA
Analog outputs
  2, configurable 0 - 10 V, 0/4 - 20 mA
Entries all-or-nothing
  3, configurable, 30 V DC max., 5 max. with analog inputs, non-parameterized
Outputs all-or-nothing
  2, user configurable, 24 V DC
Relay outputs
  2, software, with 1 normally open contact and 1 changeover contact, 6 A (250 V, AC-1) / 5 A (30 V, DC-1)
Interface/field bus (built-in)
  OP-Bus (RS485)/Modbus RTU, CANopen®
Organs of control and protection suitable
Connection to the network
   
(IEC Type B, gG), 150 %
  FAZ-B6/3
UL listed (Class CC or J)
 HasSix
150 % overload (CT/IH at 50 °C)
  DX-LN3-006
Start engine
   
150 % overload (CT/IH at 50 °C)
  DX-LM3-005
150 % overload (CT/IH at 50 °C)
  DX-SIN3-010
10 % duty cycle (FM)
  DX-BR100-0K2
20 % duty cycle (FM)
  DX-BR100-0K4
Design verification according to IEC/EN 61439(display characteristics)(hide features)
Technical specifications for verification of design
   
Rated current job for indication of the power dissipated
InHas4.3
Power dissipated in the material, a function of the current
PvidW39.75
Certificate for IEC/EN 61439
   
10.2 Strength of materials and parts
   
10.2.2 Resistance to corrosion
  The requirements of the product standard are met.
10.2.3.1 heat Resistance of the envelope
  The requirements of the product standard are met.
10.2.3.2 Resistance of insulating Materials to Heat normal
  The requirements of the product standard are met.
10.2.3.3 Resistance insulating Materials for outstanding Warmth
  The requirements of the product standard are met.
10.2.4 Resistance to UV
  The requirements of the product standard are met.
10.2.5 Elevation
  Without object to the fact that the entire apparatus must be evaluated.
10.2.6 shock Test
  Without object to the fact that the entire apparatus must be evaluated.
10.2.7 Inscriptions
  The requirements of the product standard are met.
10.3 Degree of protection of the envelope
  Without object to the fact that the entire apparatus must be evaluated.
10.4 isolation Distances and lines of flight
  The requirements of the product standard are met.
10.5 Protection against electric shock
  Without object to the fact that the entire apparatus must be evaluated.
10.6 Mounting hardware
  Without object to the fact that the entire apparatus must be evaluated.
10.7 electrical Circuits and connections internal
  Under the responsibility of the tableautier.
10.8 Connections for the conductors passed from the outside
  Under the responsibility of the tableautier.
10.9 Properties of isolation
   
10.9.2 withstand Voltage at industrial frequency
  Under the responsibility of the tableautier.
10.9.3 there Voltage shock
  Under the responsibility of the tableautier.
10.9.4 Test envelope insulation
  Under the responsibility of the tableautier.
10.10 Warm-up
  The calculation of the warm-up is under the responsibility of the tableautier. Eaton provides the data of the dissipated power of the devices.
10.11 resistance to short-circuits
  Under the responsibility of the tableautier. The specifications of the devices must be observed.
10.12 electromagnetic Compatibility
  Under the responsibility of the tableautier. The specifications of the devices must be observed.
10.13 mechanical Operation
  At the level of the device, the required conditions are met, to the extent the instructions of the installation manual (IT) are taken into account.
Technical data ETIM 5.0(View criteria)(Hide criteria)
Voltage of the network
 V200 - 240
Network frequency
  50/60 Hz
Number of phases at the entrance
  Three
Number of phases to the output
  Three
Value max. the output frequency
 HzFive hundred
Nominal output voltage
 VTwo hundred thirty
Output current rating
 Has4.3
Power output to the rated output voltage
 kW0.75
Value max. of output power with load, quadratic in the voltage nomi
 kW0.75
Value max. of the output power with linear load under the voltage-nominal
 kW0.75
With control element
  Yes
Permitted use in industrial zones
  Yes
uses allowed in the residential areas and tertiary
  Yes
Supports protocoleTCP/IP
  Not
Supports protocol PROFIBUS
  Yes
Supports CAN protocol
  Yes
Supports protocol INTERBUS
  Not
Support protocol ASI
  Not
Supports protocol EIB/KNX
  Not
Supports MODBUS protocol
  Yes
Supports protocol Data-Highway
  Not
Supports protocol DeviceNet
  Not
Supports protocol SUCONET
  Not
Protocol LON
  Not
Protocol for PROFINET IO
  Yes
Protocol for PROFINET CBA
  Not
Supports protocol SERCOS
  Not
Protocol for Foundation Fieldbus
  Not
Protocol for EtherNet/IP
  Yes
Protocol for AS-Interface Safety at Work
  Not
Protocol for DeviceNet Safety
  Not
Protocol INTERBUS Safety
  Not
Protocol for PROFIsafe
  Not
Protocol for SafetyBUS p
  Not
Supporting protocol for other bus systems
  Not
Number of interfaces industrial Ethernet
  Zero
Number of interface HW-PROFINET
  Zero
Number of interfaces serial RS-232
  Zero
Number of interfaces serial RS-422
  Zero
Number of interfaces serial RS-485
  One
Number of interfaces serial TTY
  Zero
Number of USB interfaces
  One
Number of interfaces parallel
  Zero
Number of interfaces other
  Zero
Optical Interface
  Not
With connection to PC
  Yes
Chopper (chopper) integrated braking
  Yes
Operation in 4 quadrants possible
  Not
Performance converters
  Inverter U
Protection class (IP)
  IP66
Height
 mmTwo hundred thirty one
Width
 mmOne hundred seven
Depth
 mmOne hundred eighty six
Relative tolerance of the frequency symmetrical to the network
 %Five
Tolerance relative to the voltage symmetric to the network
 %Ten
Approvals
Product Standards  UL 508C; CSA-C22.2 No. 14; IEC/EN61800-3; IEC/EN61800-5; CE marking
UL File No.  E172143
UL Category Control No.  NMMS, NMMS7
CSA File No.  UL report applies to both US and Canada
North America Certification  UL listed, certified by UL for use in Canada
Specially designed for North America  No.
Suitable for  Branch circuits
Max. Voltage Rating  3~ 240 V AC IEC: TN-S UL/CSA: Y (Solidly Grounded Wey)
Degree of Protection  IEC: IP66
Congestion
CAD data
More information on the products (links)

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.