FAZ-K16/1N 278712 EATON MOELLER FAZ-K16/1N Over current switch, 16A, 1pole+N, type K characteristic View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

FAZ-K16/1N 278712 EATON MOELLER FAZ-K16/1N Over current switch, 16A, 1pole+N, type K characteristic

FAZ-K16/1N

278712

EATON - MOELLER

Available

Ship on today

FAZ-K16/1N Over current switch, 16A, 1pole+N, type K characteristic

More details


* Brand new product in its original packaging covered by the warranties and certifications provided by EATON - MOELLER

Quantity Price
1+$62.24
5+$55.32
9+$53.71
13+$52.88
17+$52.42
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Delivery programme
Basic function
  Miniature circuit breakers
Pole
  1 pole+N
Tripping characteristic
  K
Application
  Switchgear for industrial and commercial applications
Rated current
InA16
Rated switching capacity acc. to IEC/EN 60947-2
 kA15
Product range
  FAZ
Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
   
Rated operational current for specified heat dissipation
InA16
Heat dissipation per pole, current-dependent
PvidW0
Equipment heat dissipation, current-dependent
PvidW4.8
Static heat dissipation, non-current-dependent
PvsW0
Heat dissipation capacity
PdissW0
Operating ambient temperature min.
 °C-25
Operating ambient temperature max.
 °C75
 
  linear, per +1 °C, results in a 0.5% reduction of current carrying capacity
Technical data ETIM 6.0
Circuit breakers and fuses (EG000020) / Miniature circuit breaker (MCB) (EC000042)
Electric engineering, automation, process control engineering / Electrical installation, device / Miniature circuit breaker system (MCB) / Miniature circuit breaker (MCB) ([email protected] [AAB905011])
Release characteristic
  K
Number of poles (total)
  2
Number of protected poles
  2
Nominal rated current
 A16
Nominal rated voltage
 V230
Rated short-circuit breaking capacity Icn EN 60898 at 230 V
 kA0
Rated short-circuit breaking capacity Icn EN 60898 at 400 V
 kA0
Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V
 kA15
Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V
 kA15
Voltage type
  AC
Current limiting class
  3
Frequency
 Hz50 - 60
Concurrently switching N-neutral
  Yes
Suitable for flush-mounted installation
  No
Over voltage category
  3
Pollution degree
  2
Width in number of modular spacings
  2
Built-in depth
 mm70.5
Additional equipment possible
  Yes
Degree of protection (IP)
  IP20

Datasheet - PDF

Title: Language: Size: Type:
EATON MOELLER-278712-FAZ-K16/1N English 137 Kbytes EATON MOELLER-278712-FAZ-K16/1N

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.