ESR5-NO-31-UC 191796 EATON ELECTRIC Safety relay emergency stop/protective door/light curtain monitoring wit.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

ESR5-NO-31-UC 191796 EATON ELECTRIC Safety relay emergency stop/protective door/light curtain monitoring wit..

ESR5-NO-31-UC

191796

EATON-MOELLER

Safety relay emergency stop/protective door/light curtain monitoring with wide range input, 24 V-230 VDC/AC

ESR5-NO-31-UC

More details


Relays > Device for monitoring of safety-related circuits

Relay timers (KETR, KEMR, KESR)

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $443.96
Unit price: $443.96

Quantity Price
1+$443.96
2+$412.87
3+$411.98
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



General specifications

Product Name
Eaton ESR5 Safety relay
Catalog Number
191796
Model Code
ESR5-NO-31-UC
EAN
4015081923151
Product Length/Depth
114.5 mm
Product Height
113 mm
Product Width
22.5 mm
Product Weight
0.17 kg
Certifications
Certified by UL for use in Canada
CSA-C22.2 No. 14-95
IEC/EN 60947-5-1
UL 508
2014/30/EU
CE
IEC 62061
UL report applies to both US and Canada
EN 50156-1
EN ISO 13849-1
UL
UL File No.: E29184
IEC 61508, Parts 1-7
Machines 2006/42/EG

Feature & Functions

Electric connection type
Screw connection
Features
Start button monitoring
4 kV basic insulation between all current paths and enclosure
4 kV basic insulation between 23/24 and 33/34 enable signal current paths and 41/42 signaling current path
Manual start
3 Non-delayed enable current paths
Safe insulation
Automatic start
6 kV reinforced insulation between all other current paths
Fitted with:
Detachable clamps
Approval according to UL
Start input
Feedback circuit
Functions
2-channel
1-channel

General information

Connection type
M3 screw terminals
Degree of protection
Terminals: IP20
Installation location: ≥ IP54
IP20
Enclosure: IP20
LED indicator
Status indication of SmartWire-DT network: Green LED
Lifetime
240 month
Model
Basic device
Mounting method
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Rail mounting possible
Mounting width
22.5 mm
Overvoltage category
III
Pollution degree
2
Product category
Electronic safety relays
Safety performance level (EN ISO 13849-1)
Level e
Safety parameter (IEC 62061)
Cat. 4, Category
SIL 3, Safety integrity level, In accordance with IEC 61508
10 x 10-10, PFHd, Probability of failure per hour
SILCL 3, Safety integrity level claim limit
SIL 3, Safety integrity level
Stop category (IEC 60204)
0
Suitable for
Monitoring of magnetic switches
Monitoring of emergency-stop circuits
If the sensor circuit is interrupted, the safety relay switches to safe mode
Module used to safely interrupt electrical circuits
Monitoring of optoelectronic protection equipment
Safety relay for monitoring one or two-channel signal generators and control of actuators
Switching frequency
Max. 1 Hz, Input data
Type
Voltage type
AC/DC

Ambient conditions, mechanical

Mounting position
As required
Prooftest
56 Months (Low Demand)
240 Months (High Demand)
Switching capacity
0.05 W
5 A, DC-13 at 24 V, Outputs

Climatic environmental conditions

Air pressure
795 - 1080 hPa (operation)
Altitude
Max. 2000 m
Ambient operating temperature - min
-40 °C
Ambient operating temperature - max
55 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
85 °C
Environmental conditions
Condensation: Non-condensing
Operating temperature - min
-40 °C
Operating temperature - max
55 °C
Relative humidity
< 75 %

Electrical rating

Rated control supply voltage (Us) at AC, 50 Hz - min
24 V
Rated control supply voltage (Us) at AC, 50 Hz - max
230 V
Rated control supply voltage (Us) at AC, 60 Hz - min
24 V
Rated control supply voltage (Us) at AC, 60 Hz - max
230 V
Rated control supply voltage (Us) at DC - min
24 V
Rated control supply voltage (Us) at DC - max
230 V
Rated insulation voltage (Ui)
250 V
Rated operational voltage
230 V AC
Short-circuit protection
6 A gL/gG, For output circuits, External

Input/Output

Breaking power
40 W max., inductive load (τ = 40 ms), at 48 V DC
35 W max., inductive load (τ = 40 ms), at 110 V DC
1500 VA, max., resistive load (τ = 0 ms), at 250 V AC
48 W max., inductive load (τ = 40 ms), at 24 V DC
33 W max., inductive load (τ = 40 ms), at 220 V DC
Input
∞ ms, Simultaneity for inputs 1/2
Number of inputs
One- and two-channel
Number of outputs (safety related, delayed) with contact
0
Number of outputs (safety related, undelayed) with contact
0
Number of outputs (signaling function, delayed) with contact
0
Number of outputs (signaling function, undelayed) with contact
0
Pick-up time
< 100 ms typ. (at Uₑ in manual mode)
< 150 ms typ. (at Uₑ in automatic mode)
Quadratic summation current
72 A² (ITH² = I1² + I2² + In²)
Reset time
Normally < 20 ms (when driven via the sensor circuits)
Uninterrupted current
6 A N/O, Limiting continuous current

Design verification

Equipment heat dissipation, current-dependent Pvid
2.7 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
2.9 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.