EMR6-N1000-A-1 184757 EATON ELECTRIC Level monitoring relays, 24 240 V AC, 50/60 Hz, 24 240 V DC, 0.1 1000 kΩ View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

EMR6-N1000-A-1 184757 EATON ELECTRIC Level monitoring relays, 24 240 V AC, 50/60 Hz, 24 240 V DC, 0.1 1000 kΩ

EMR6-N1000-A-1

184757

Y7-184757

EATON-MOELLER

Level monitoring relays, 24 - 240 V AC, 50/60 Hz, 24 - 240 V DC, 0.1 - 1000 kΩ

EMR6-N1000-A-1

Eaton Moeller® series EMR6 Level monitoring relays, 24 - 240 V AC, 50/60 Hz, 24 - 240 V DC, 0.1 - 1000 kΩ

More details


Relays > (Fill) level monitoring relay

Relay timers (KETR, KEMR, KESR)

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $209.63
Unit price: $209.63

Quantity Price
1+$209.63
2+$186.86
3+$177.59
4+$172.35
6+$168.89
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



General specifications

Product Name
Eaton Moeller® series EMR6 Liquid level monitoring relay
Catalog Number
184757
Model Code
EMR6-N1000-A-1
EAN
4015081787937
Product Length/Depth
103.7 mm
Product Height
85.6 mm
Product Width
22.5 mm
Product Weight
0.143 kg
Certifications
EAC
EN 61557
GL
RCM
IEC/EN 60255-6
DNV
RMRS
UL
CSA

Features & Functions

Electric connection type
Screw connection
Functions
Response value sensitivity adjustable
Monitoring function
Mixture ratio of conductive liquids
Fill level of conductive liquids

General

Degree of protection
Enclosure: IP50
Terminals: IP20
Lifespan, mechanical
10,000,000 Operations
Mounting position
As required
Overvoltage category
III
Pollution degree
3
Product category
EMR Measuring and monitoring relays
Rated impulse withstand voltage (Uimp)
4000 V AC
Shock resistance
Class 2
LED indicator
Status indication of Min and Max occupied: Yellow, solid light
Status indication of active release delay: Green, flashing light
Status indication of Supply voltage: Green, solid light
Status indication of Min occupied: Yellow, flashing light
Status indication of Supply voltage: Green LED
Status indication of Output relay excited: Yellow, solid light (R)
Status indication of energized output relay: Yellow LED
Type
Level monitoring relay
Voltage type
AC/DC
Voltage type
AC/DC

Climatic environmental conditions

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
60 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
85 °C
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30

Electro magnetic compatibility

Air discharge
Air/contact discharge, according to IEC/EN 61000-4-2, level 3
Burst impulse
According to IEC/EN 61000-4-4, level 3
Electromagnetic compatibility
According to IEC/EN 60947-6-2
Immunity to line-conducted interference
Level 3 (according to IEC/EN 61000-4-6)
Immunity to radiation
Level 3 (according to IEC/EN 61000-4-3)
Surge rating
According to IEC/EN 61000-4-5 Level 4

Terminal capacities

Connection type
Snap fixing, top-hat rail IEC/EN 60715
Terminal capacity
2 x (0.5-1.5) mm², (2 x (18-16) AWG), flexible with ferrule
1 x (0.5-2.5) mm², (1 x (18-14) AWG), solid
Screwdriver size
5.5 x 0.8 mm, Terminal screw
Tightening torque
Min. 0.5 Nm, Screw terminals
0.8 Nm, Screw terminals

Timing cycle

Adjustment range
0.1 - 1000 kΩ, Sensitivity

Power supply

Duty factor
100 %, Power supply
Power consumption
2.6 VA
Rated control supply voltage (Us) at AC, 50 Hz - min
24 V
Rated control supply voltage (Us) at AC, 50 Hz - max
240 V
Rated control supply voltage (Us) at AC, 60 Hz - min
24 V
Rated control supply voltage (Us) at AC, 60 Hz - max
240 V
Rated control supply voltage (Us) at DC - min
24 V
Rated control supply voltage (Us) at DC - max
240 V
Rated frequency - min
50 Hz
Rated frequency - max
60 Hz
Supply voltage
24 - 240 V AC, 50/60 Hz
24 - 240 V DC
Voltage tolerance
0.85 x Uc
1.1 x Uc

Measuring circuits

Connection
Minimum level, MIN, Sensor inputs, Measuring circuits
Earth reference sensor, C, Sensor inputs, Measuring circuits
Maximum level, MAX, Sensor inputs, Measuring circuits
Sensor voltage
6 VAC

Relay output contacts

Number of contacts (change-over contacts)
2
Number of contacts (normally closed contacts)
0
Number of contacts (normally open contacts)
0
Lifespan, electrical
100,000 Operation (at 230 V, AC-12, 4 A)
Rated operational current (Ie)
5 A at AC-12, 230 V
2 A at DC-12, 24 V
3 A at AC-15, 230 V
Rated operational voltage (Ue) at AC - max
300 V
Short-circuit protection rating
Max. 10 A Fast/gL, Fuse, Relay output contacts
Short-circuit protection rating
Max. 10 A Fast/gL, Fuse, Relay output contacts

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.