ANUNCIAR
DM1-342D2EB-S20S-EM 3-5009-006A EATON ELECTRIC DM1-342D2EB-S20S-EM View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DM1-342D2EB-S20S-EM 3-5009-006A EATON ELECTRIC DM1-342D2EB-S20S-EM

DM1-342D2EB-S20S-EM

3-5009-006A

3-5009-006A

EATON-MOELLER

DM1-342D2EB-S20S-EM

Eaton DM1 Variable frequency drive, 400 V AC, 3-phase, 2.2 A, 0.75 kW, IP20/NEMA0, Radio interference suppression filter, 7-digital display assembly, Setpoint potentiometer, Brake chopper, FS1

Variable frequency drive DM1, Mains voltage: 380 - 480 V AC, 3-phase, Nominal output current: 2.2 A, Output at linear load at rated output voltage - max: 0.75 kW, fitted with: Radio interference suppression filter, IGBT inverter, DC link choke, 7-digital display assembly, Setpoint potentiometer, Brake chopper, Internal DC link, Breaking resistance, Control unit, PC connection, Frame Size: FS1

More details


Low-voltage industrial components > Frequency converter less than 1 kV

Power XL Frequency Converters

Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total: $456.53
Unit price: $456.53
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



General specifications

Product Name
Eaton DM1 Variable frequency drive
Catalog Number
3-5009-006A
Model Code
DM1-342D2EB-S20S-EM
EAN
4015081980994
Product Length/Depth
180 mm
Product Height
152 mm
Product Width
72 mm
Product Weight
1.2 kg
Certifications
Certified by UL for use in Canada
EAC
IEC/EN 61800-5-1
IEC/EN61800-5
IEC/EN 61800-3
UL 508C
RoHS, ISO 9001
UL Category Control No.: NMMS, NMMS7
UL File No.: E134360
CUL
IEC/EN61800-3
UL Listed
UL
IEC/EN 61800-2
UkrSEPRO
CSA-C22.2 No. 274-13
CE marking
UL report applies to both US and Canada
C-Tick
CE
CSA-C22.2 No. 274-17

General

Air volume capacity
26 m³/h
Cable length
C3 ≤ 25 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length
Communication interface
SmartWire-DT, optional
Modbus RTU, built in
BACnet TCP
CANopen®, optional
PROFIBUS, optional
Ethernet IP, built in
BACnet MS/TP, built in
Modbus TCP, built in
DeviceNet, optional
Connection to SmartWire-DT
Yes
In conjunction with DXG-NET-SWD SmartWire DT module
Degree of protection
IP20
NEMA Other
Electromagnetic compatibility
1st and 2nd environments (according to EN 61800-3)
Environmental class
3C2, 3S2 (Air quality)
Features
Temperature-controlled fan
Parameterization: Power Xpert inControl
Parameterization: Keypad
Parameterization: Fieldbus
Fitted with:
Radio interference suppression filter
IGBT inverter
7-digital display assembly
Setpoint potentiometer
Brake chopper
Internal DC link
Breaking resistance
Control unit
PC connection
Frame size
FS1
Mounting position
Vertical
Number of slots
1 (expansion)
Overvoltage category
III
Pollution degree
2
Product Category
Variable frequency drives
Protection
Finger and back-of-hand proof, Protection against direct contact (BGV A3, VBG4)
Radio interference class
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
C1: with external filter, for conducted emissions only
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Safety function/level
STO (Safe Torque Off, SIL2, PLc Cat 2)
Shock resistance
0.75 mm (peak) at 10 - 57 Hz, max. 1 g at 57 - 150 Hz, according to EN 61800-5-1, EN 60068-2-6: 10 - 150 Hz
Suitable for
Branch circuits, (UL/CSA)

Climatic environmental conditions

Altitude
Max. 3000 m
Above 1000 m with 1 % derating per 100 m
Max. 1000 m
Max. 2000 m for Corner Grounded TN Systems
Ambient operating temperature - min
-10 °C
Ambient operating temperature - max
50 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
70 °C
Climatic proofing
< 95 average relative humidity (RH), no condensation, no corrosion

Main circuit

Current limitation
0.1 - 2 x IH (CT), motor, main circuit
Input current ILN at 110% overload
5.2 A
Input current ILN at 150% overload
2.6 A
Mains current distortion
40 %
Mains switch-on frequency
Maximum of one time every 60 seconds
Mains voltage - min
380 V
Mains voltage - max
480 V
Operating mode
U/f control
Speed control with slip compensation
PM motors
Sensorless vector control (SLV)
Torque regulation
Output frequency - min
0 Hz
Output frequency - max
400 Hz
Output voltage (U2)
500 V AC, 3-phase
480 V AC, 3-phase
400 V AC, 3-phase
Overload current IL at 110% overload
4.73 A
Overload current IL at 150% overload
3.3 A
Rated conditional short-circuit current (Iq)
100 kA
Rated control supply voltage
10 V DC (Us, max. 10 mA)
Rated frequency - min
45 Hz
Rated frequency - max
66 Hz
Rated operational current (Ie) at 110% overload
4.3 A
Rated operational current (Ie) at 150% overload
2.2 A
Rated operational power at 380/400 V, 50 Hz, 110% overload
1.5 kW
Rated operational power at 380/400 V, 50 Hz, 3-phase
0.75 kW
Rated operational power at 500 V, 50 Hz, 3-phase
1.1 kW
Rated operational power at 500 V, 50 Hz, 3-phase, 110% overload
2.2 kW
Rated operational voltage
400 V AC, 3-phase
500 V AC, 3-phase
480 V AC, 3-phase
Resolution
0.01 Hz (Frequency resolution, setpoint value)
Short-circuit protection rating
6.3 A, UL (Class CC or J), Safety device (fuse or miniature circuit-breaker), Power Wiring
Starting current - max
200 %, IH, max. starting current (High Overload), For 2 seconds every 20 seconds, Power section
Supply frequency
50/60 Hz
Switching frequency
4 kHz, 1 - 16 kHz adjustable, fPWM, Power section, Main circuit
System configuration type
TN-S, TN-C, TN-C-S, TT, IT
Voltage rating - max
500 V

Motor rating

Assigned motor current IM at 400 V, 50 Hz, 110% overload
3.6 A
Assigned motor current IM at 400 V, 50 Hz, 150% overload
1.9 A
Assigned motor current IM at 440 - 480 V, 60 Hz, 150% overload
2.1 A
Assigned motor current IM at 500 V, 50 Hz, 110% overload
4 A
Assigned motor current IM at 500 V, 50 Hz, 150% overload
2.1 A
Assigned motor power at 460/480 V, 60 Hz
1 HP
Assigned motor power at 460/480 V, 60 Hz, 110% overload
2 HP

Braking function

Braking resistance
105 Ω
Braking torque
Max. 30 % MN, Standard - Main circuit
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit
Adjustable to 150 %, DC - Main circuit
Switch-on threshold for the braking transistor
800 VDC

Control circuit

Number of inputs (analog)
1
Number of inputs (digital)
4
Number of outputs (analog)
1
Number of relay outputs
2 (parameterizable, 1 changeover contact and 1 N/O, 3 A (240 V AC) / 3 A (24 V DC))
Rated control voltage (Uc)
24 V DC (external, max. 100 mA options incl.)

Design verification

Equipment heat dissipation, current-dependent Pvid
65 W
Rated operational current for specified heat dissipation (In)
4.3 A
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 3-5009-006A Low-voltage industrial controls and switchgear (EC001857)
Feature Name Feature Value
Mains voltage (EF006780) 380 V
Mains frequency (EF006783) 50/60 Hz
Number of phases input (EF007117) 3
Number of phases output (EF006998) 3
Max. output frequency (EF007350) 400 Hz
Max. output voltage (EF009560) 500 V
Nominal output current I2N (EF009561) 2.2 A
Max. output at quadratic load at rated output voltage (EF007366) 1.5 kW
Max. output at linear load at rated output voltage (EF007364) 0.75 kW
Power consumption (EF000346) 65 W
Relative symmetric net frequency tolerance (EF007454) 10 %
Relative symmetric net voltage tolerance (EF007453) 10 %
Number of analogue outputs (EF001995) 1
Number of analogue inputs (EF001994) 1
Number of digital outputs (EF001993) 0
Number of digital inputs (EF001992) 4
With control element (EF001538) Yes
Application in industrial area permitted (EF007294) Yes
Application in domestic- and commercial area permitted (EF007295) Yes
Supporting protocol for TCP/IP (EF003050) Yes
Supporting protocol for PROFIBUS (EF003052) Yes
Supporting protocol for CAN (EF003053) Yes
Supporting protocol for INTERBUS (EF003054) No
Supporting protocol for ASI (EF003051) No
Supporting protocol for KNX (EF003055) No
Supporting protocol for Modbus (EF003057) Yes
Supporting protocol for Data-Highway (EF003058) No
Supporting protocol for DeviceNet (EF003059) No
Supporting protocol for SUCONET (EF003060) No
Supporting protocol for LON (EF003017) No
Supporting protocol for PROFINET IO (EF007525) No
Supporting protocol for PROFINET CBA (EF007524) No
Supporting protocol for SERCOS (EF006657) No
Supporting protocol for Foundation Fieldbus (EF007522) No
Supporting protocol for EtherNet/IP (EF007521) Yes
Supporting protocol for AS-Interface Safety at Work (EF007519) No
Supporting protocol for DeviceNet Safety (EF007520) No
Supporting protocol for INTERBUS-Safety (EF006662) No
Supporting protocol for PROFIsafe (EF007526) No
Supporting protocol for SafetyBUS p (EF007527) No
Supporting protocol for BACnet (EF011944) Yes
Supporting protocol for other bus systems (EF003062) Yes
Number of HW-interfaces industrial Ethernet (EF003020) 1
Number of interfaces PROFINET (EF006932) 0
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 1
Number of HW-interfaces serial TTY (EF003024) 0
Number of HW-interfaces USB (EF003025) 0
Number of HW-interfaces parallel (EF003026) 0
Number of HW-interfaces other (EF003027) 1
With optical interface (EF003028) No
With PC connection (EF006107) Yes
Integrated breaking resistance (EF007293) Yes
4-quadrant operation possible (EF006803) Yes
Type of converter (EF006978) U converter
Degree of protection (IP) (EF005474) IP20
Degree of protection (NEMA) (EF011959) Other
Height (EF000040) 152 mm
Width (EF000008) 72 mm
Depth (EF000049) 180 mm

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.