DILM32-11(230V50/60HZ)-PI 199670 EATON ELECTRIC DILM32-11(230V50/60HZ)-PI View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DILM32-11(230V50/60HZ)-PI 199670 EATON ELECTRIC DILM32-11(230V50/60HZ)-PI

DILM32-11(230V50/60HZ)-PI

199670

Y7-199670

EATON-MOELLER

DILM32-11(230V50/60HZ)-PI

Eaton Moeller® Series DILM contactor, 3-pole, 380 V 400 V 15 kW, 1 NO, 1 NC, 230 V 50/60 Hz, AC operation, snap-on terminals

More details


Contactors up to 170A

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $100.92
Unit price: $100.92

Quantity Price
1+$100.92
2+$88.66
3+$88.32
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Viewed products


Best sellers

More info



General Specifications

Product Name
Eaton Moeller® DILM Contactor Series
Catalog No.
199670
Ean
4015081983711
Product Length/Depth
115 mm
Product Height
85 mm
Product Width
45 mm
Product Weight
0.441 kg
Certification(s)
IEC/EN 60947
VDE 0660
Model Code
DILM32-11(230V50/60HZ)-PI

Product specifications

Number of poles
Tripolar
Equipped with:
Mirror Contacts
Manoeuvring frequency
5,000 mechanical operations/h (AC drive)
Degree of contamination
3
Climatic Resistance
Moist heat, constant, according to IEC 60068-2-78
Moist, cyclic heat according to IEC 60068-2-30
Connecting to SmartWire-DT
No
Assigned Voltage Supported to Impulse (Uimp)
8,000 V AC
Category of use
AC-4: AC Induction Motors: Start, Connection, Reverse, Idle
AC-3: AC Induction Motors: Start, Off During Operation
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
Connection
Push-in Terminals
Frame Size
FS2
Ambient Operating Temperature - Max.
60 °C
Ambient Operating Temperature - Min.
-25 °C
Ambient Operating Temperature (Closed) - Max.
40 °C
Ambient Operating Temperature (Closed) - Min.
25 °C
Ambient storage temperature - max.
80 °C
Ambient storage temperature - min.
40 °C
Conventional thermal current Ith (1 pole, in housing)
90 A
Conventional thermal current Ith (3 poles, in housing)
36 A
Conventional thermal current Ith at 55 °C (3 poles, open)
42 A
Conventional Thermal Current Ith of Main Contacts (1 Pole, Open)
100 A
application
Contactors for motors
Product Category
Contactors
Protection
Finger and back of hand proof, Protection against direct contact when operated from the front (EN 50274)
Arc Duration
10 ms
Main Circuit Electrical Connection Type
Spring Connection
Screwdriver Size
3 x 0.5 mm, screw terminal
3.0 x 0.5 mm, screw terminal
Type of voltage
Ac
Degree of protection
IP20
Number of auxiliary contacts (opening contacts)
1
Number of auxiliary contacts (normally open contacts)
1
Number of contacts (normally closed contacts)
1
Number of contacts (opening contacts) as the primary contact
0
Number of contacts (normally open contacts)
1
Number of primary contacts (normally open contacts)
3
Rated interrupting capacity at 220/230 V
320 A
Interrupting rating at 380/400 V
320 A
Rated interrupting capacity at 500 V
320 A
Rated interrupting capability at 660/690 V
180 A
Nominal control supply voltage (Us) in AC, 50 Hz - max.
230 V
Nominal control supply voltage (Us) in AC, 50 Hz - min.
230 V
Nominal control supply voltage (Us) in AC, 60 Hz - max.
230 V
Nominal control supply voltage (Us) in AC, 60 Hz - min.
230 V
Stress on Fall
AC Drive: 0.6 - 0.3 x UC, AC Drive
Surge Category
Iii
Utilization Factor
100%
Interference emission
According to EN 60947-1
Immunity to interference
According to EN 60947-1
Service life, mechanical
10,000,000 Operations (AC Drive)
Call Voltage
0.8 - 1.1 V AC x UC
Power Absorbed, Call, 50 Hz
58 VA, bi-frequency coil in cold state and 1.0 x Us
62 VA, bi-frequency coil in cold state and 1.0 x Us
Safe sectioning
400 V AC, Between coil and contacts, According to EN 61140
400 V AC, Between contacts, according to EN 61140
Power Absorbed, Call, 60 Hz
58 VA, bi-frequency coil in cold state and 1.0 x Us
62 VA, bi-frequency coil in cold state and 1.0 x Us
Power Absorbed, Retention, 50 Hz
2.1 W, bi-frequency coil in cold state and 1.0 x Us
Power Absorbed, Retention, 60 Hz
6.5 VA, bi-frequency coil in cold state and 1.0 x Us, at 60 Hz
2.1 W, bi-frequency coil in cold state and 1.0 x Us
9.1 VA, bi-frequency coil in cold state and 1.0 x Us, at 60 Hz
Terminal Capacity (Flexible with Terminal)
1 x (1 - 6) mm²
1 x (0.5 - 1.5) mm², Manoeuvring cables
2 x (0.5 - 1.5) mm², Main cables
2 x (1 - 4) mm²
Impact Resistance
7 g, Auxiliary contact NO, Mechanical, according to IEC/EN 60068-2-27, Semi-sinusoidal shock 10 ms
10 g, Auxiliary contact NO, Mechanical, according to IEC/EN 60068-2-27, Semi-sinusoidal shock 10 ms
5 g, NC auxiliary contact, mechanical, according to IEC/EN 60068-2-27, semi-sinusoidal shock 10 ms
6.5 g, main contact NO, mechanical, according to IEC/EN 60068-2-27 when mounted on a table, 10 ms semi-sinusoidal impact
8 g, main contact NO, mechanical, according to IEC/EN 60068-2-27 when mounted on a table, semi-sinusoidal shock 10 ms
2 g, NC auxiliary contact, mechanical, according to IEC/EN 60068-2-27 when mounted on a table, semi-sinusoidal shock 10 ms
Terminal Capacity (Rigid)
2 x (1 - 6) mm²
1 x (1 - 6) mm²
1 x (0.5 - 0.25) mm²
2 x (0.5 - 2.5) mm², Manoeuvring cables
Terminal Capacity (Rigid/Stranded AWG)
20 - 14
18 - 8, Main Cables
Terminal Capacity (Flexible)
2 x (1-6) mm²
1 x (0.5 - 2.5) mm²
2 x (0.5 - 2.5) mm²
1 x (1 - 10) mm²
Nominal Control Supply Voltage (Us) in DC - Max.
0 V
Nominal Control Supply Voltage (Us) in DC - Min.
0 V
Rated Insulation Voltage (Ui)
690 V
Assigned closing power up to 690 V (cos phi according to IEC/EN 60947)
384 A
Assigned current of use (Ie) in AC-1, 380 V, 400 V, 415 V
45 A
Assigned current (Ie) in AC-3, 220 V, 230 V, 240 V
32 A
Assigned current (Ie) in AC-3, 380 V, 400 V, 415 V
32 A
Assigned Current of Use (Ie) in AC-3, 440 V
32 A
Assigned Operating Current (Ie) in AC-3, 500 V
32 A
Assigned Current of Use (Ie) in AC-3, 660 V, 690 V
18 A
Assigned current of use (Ie) in AC-4, 220 V, 230 V, 240 V
15 A
Assigned current (Ie) in AC-4, 400 V
15 A
Assigned Current of Use (Ie) in AC-4, 440 V
15 A
Assigned current of use (Ie) in AC-4, 500 V
15 A
Assigned current of use (Ie) in AC-4, 660 V, 690 V
12 A
Assigned Current of Use (Ie) in DC-1, 110 V
40 A
Assigned Current of Use (Ie) in DC-1, 220 V
40 A
Assigned Current of Use (Ie) in DC-1, 60 V
40 A
Rated power for use in AC-3, 240 V, 50 Hz
11 kW
AC-3 rated power, 380/400 V, 50 Hz
15 kW
Rated power for use in AC-3, 415 V, 50 Hz
19 kW
AC-4 rated power, 220/230 V, 50 Hz
4 kW
Rated power for use in AC-4, 240 V, 50 Hz
4.5 kW
Rated power for use in AC-4, 380/400 V, 50 Hz
7 kW
AC-4 rated power, 415 V, 50 Hz
7.5 kW
Rated power for use in AC-4, 440 V, 50 Hz
8 kW
Power rated for use in AC-4, 500 V, 50 Hz
9 kW
Rated power for use in AC-4, 660/690 V, 50 Hz
10 kW
Assigned Power of Use (NEMA)
0 kW
Assigned Operating Voltage (Ue) in AC - Max.
690 V
Switching time (AC acc., contact closure, closing delay) - max.
22 ms
Switching Time (AC Acc., Contact Shutdown, Shutdown Delay) - min.
16 ms
Switching time (AC acc., contact closing, opening delay) - max.
14 ms
Switching Time (AC Acc., Contact Closure, Opening Delay) - Min.
8 ms
Short-circuit current rating (high fault at 480 V)
65 kA, CB, SCCR (UL/CSA)
32 A, max. CB, SCCR (UL/CSA)
Nominal short-circuit protection (type 1 coordination) at 400 V
125 A gG/gL
Suitable for
Motors with efficiency class IE3 are also available
Nominal short-circuit protection (type 1 coordination) at 690 V
63 A gG/gL
Nominal short-circuit protection (type 2 coordination) at 400 V
63 A gG/gL
Nominal short-circuit protection (type 2 coordination) at 690 V
35 A gG/gL
AC service voltage at 50 Hz - Min.
24 V
AC operating voltage at 50 Hz - Max.
690 V
AC service voltage at 60 Hz - Min.
24 V
AC operating voltage at 60 Hz - Max.
690 V

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.