ANUNCIAR
CR2020024 135177 Y7-135177 EATON ELECTRIC Modular contactor, 24 V AC/DC, 2NA, 20A, 1UM View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

CR2020024 135177 Y7-135177 EATON ELECTRIC Modular contactor, 24 V AC/DC, 2NA, 20A, 1UM

CR2020024

135177

Y7-135177

EATON-MOELLER

Modular contactor, 24 V AC/DC, 2NA, 20A, 1UM

CR2020024

Installation contactor, 20A, 24V AC/DC, 2NO

Installation contactor, rated control circuit voltage 24V AC/DC, rated operational current at AC1 20A, function: 2NO, details according to IEC/EN 61095, IEC/EN 60947-4-1, standard front dimension 45 mm, mounting width 1 MU, top-hat rail mounting

More details


Devices for distribution board-/surface mounting > Installation contactor for distribution board

Modular Switchgear – Others and Accessories

Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total: $59.93
Unit price: $59.93
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



General specifications

Product Name
Eaton CR contactor
Catalog Number
135177
Model Code
CR2020024
EAN
8711426746831
Product Length/Depth
75 mm
Product Height
80 mm
Product Width
18 mm
Product Weight
0.133 kg
Compliances
RoHS conform

Product specifications

Amperage Rating
20 A
Features
Additional equipment possible
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Degree of protection
IP20
Equipment heat dissipation, current-dependent
2.1 W
Heat dissipation per pole, current-dependent
1.7 W
Incandescent lamp load - max
1950 W
Load fluorescent lamp - max
910 VA
Load fluorescent lamp (duo circuit) - max
1160 VA
Load fluorescent lamp (parallel compensated) - max
232 VA
Number of contacts (normally closed contacts)
0
Number of contacts (normally open contacts)
2
Number of modular spacings
1
Rated operating voltage (Ue) - max
400 V
Rated operating voltage (Ue) - min
400 V
Rated operational current for specified heat dissipation (In)
20 A
Utility category
1
Voltage rating (excitation) - max
26.4 V
Voltage rating (excitation) - min
20.4 V
Built-in depth
60 mm
Voltage type
AC/DC
Utilization category (according to EN IEC 60947-4-1)
AC-1

ETIM for 135177 Modular devices for distribution board/surface mounting (EC001653)
Feature Name Feature Value
Rated operating voltage (EF001435) 400 V
Rated operation current (EF007679) 20 A
Utilization category according to EN IEC 60947-4-1 (EF017125) AC-1
Rated excitation voltage (EF008409) 20.4 V
Voltage type (operating voltage) (EF005294) AC/DC
Voltage type (excitation voltage) (EF005293) AC/DC
Number of contacts as normally open contact (EF008256) 2
Number of contacts as normally closed contact (EF008255) 0
Max. incandescent lamp load (EF004952) 1950 W
Max. load fluorescent lamp (EF004971) 910 VA
Max. load fluorescent lamp (Duo circuit) (EF004972) 1160 VA
Max. load fluorescent lamp (parallel compensated) (EF004973) 232 VA
Slider for hand switch (EF005240) No
Width in number of modular spacings (EF002950) 1
Built-in depth (EF000218) 60 mm
Additional equipment possible (EF008148) Yes
With day/night function (EF021124) No
Hum-free (EF016334) No
Degree of protection (IP) (EF005474) IP20

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.