STZ0,315(*/*) 914766 EATON ELECTRIC Control transformer, 315VA, 1p, non-standard voltage View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

STZ0,315(*/*) 914766 EATON ELECTRIC Control transformer, 315VA, 1p, non-standard voltage

STZ0,315(*/*)

914766

-

EATON-MOELLER

Control transformer, 315VA, 1p, non-standard voltage

STZ0,315(*/*)

Control transformer, 0.315 kVA, Rated input voltage 50 – 950 ± 5 % V, Rated output voltage 12 – 1000 V

More details


Low-voltage industrial components > One-phase control transformer

Transformers

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $208.24
Unit price: $208.24

Quantity Price
1+$208.24
2+$184.75
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Control transformer, 0.315 kVA, Rated input voltage 50 – 950 ± 5 % V, Rated output voltage 12 – 1000 V
Control transformer, Product range: Single-phase control transformers ST..., Basic function: Single-phase control, isolating and safety transformers STI, STZ, Rated input voltage: 50 – 950 ± 5 % V, Rated output voltage: 12 – 1000 V, Rated power: 0.315 kVA, Short-time rating: 0.75 kVA, Degree of Protection: IP00, Standards Built and tested to: IEC/EN 61558-2-2/2-4/2-6, VDE 0570 Part 2-2, VDE 0570 Part 2-6 (safety transformers), VDE 0570 Part 2-4 (isolating transformer), Suitable for use to: IEC/EN 60204-1, ÖVE-EN 13, VDE 0113, VDE 0100 Part 410

Delivery program

Product range
Single-phase control transformers ST...
Basic function
Single-phase control, isolating and safety transformers STI, STZ
Rated input voltage
50 – 950 ± 5 % V
Rated output voltage
12 – 1000 V
Rated power
0.315 kVA
Short-time rating
0.75 kVA
Cu factor
1,10 kg
Notes
  • Transformers with the rated output voltages ≦ 50 V can be used as safety transformers to IEC/EN 61558.
  • UL/CSA only up to primary and secondary 600 V (incl. tapping).

When ordering, the type reference must include the following details:

STZ0,06(*/*)

1st wildcard ≙ Nominal input voltage

2nd wildcard ≙ Rated output voltage

Ordering example
  • Desired part no. STZ0,06
  • Desired rated input voltage 230 V
  • Desired rated output voltage 12 V

The correct type reference is

STZ0,06(230/12)

Additional tappings → 931897

Technical data

General
StandardsBuilt and tested to
IEC/EN 61558-2-2/2-4/2-6
VDE 0570 Part 2-2
VDE 0570 Part 2‐6 (safety transformers)
VDE 0570 Part 2-4 (isolating transformer)
StandardsSuitable for use to
IEC/EN 60204-1, ÖVE-EN 13
VDE 0113, VDE 0100 Part 410
Ambient temperature
-25 - 40
Characteristics
Terminations
● (< 63 A)
Connection lugs
● (< 63 A)
Insulation class
B
Rated frequency
50 - 60 Hz
Primary tapping
± 5 %
Degree of Protection
IP00
Separate windings
Fully vacuum-impregnated
Reinforced insulation
Rated duty factor
100 % DF
Electrical characteristics
Note
The following applies for the no-load loss, short-circuit loss (copper losses), short-circuit voltage and efficiency values: all details relate to a temperature of 20 °C
Total weight
4.3 kg
No-load losses
10 W
Short-circuit losses
18 W
Shortcircuit voltage
5.5 %
Efficiency
0.92

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
0 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
28 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+40 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / One-phase control transformer (EC002486)
Electric engineering, automation, process control engineering / Transformer, converter, coil / Control transformer / One-phase control transformer ([email protected] [AAB620015])
Built as safety transformer
Yes
Built as isolating transformer
Yes
Built as energy saving transformer
No
Primary voltage 1
50 - 950 V
Primary voltage 2
50 - 950 V
Primary voltage 3
50 - 950 V
Primary voltage 4
50 - 950 V
Primary voltage 5
50 - 950 V
Primary voltage 6
50 - 950 V
Primary voltage 7
0 - 0 V
Primary voltage 8
0 - 0 V
Primary voltage 9
0 - 0 V
Primary voltage 10
0 - 0 V
Secondary voltage 1
12 - 1000 V
Secondary voltage 2
12 - 1000 V
Secondary voltage 3
12 - 1000 V
Secondary voltage 4
12 - 1000 V
Secondary voltage 5
12 - 1000 V
Secondary voltage 6
12 - 1000 V
Secondary voltage 7
0 - 0 V
Secondary voltage 8
0 - 0 V
Secondary voltage 9
0 - 0 V
Secondary voltage 10
0 - 0 V
Rated apparent power
315 VA
Type of insulation material acc. IEC 85
B
Short-circuit-proof
No
Relative short circuit voltage
5.5 %
Width
121 mm
Height
131 mm
Depth
88 mm
Degree of protection (IP)
IP00
Ring core
No
Suitable for mounting on PCB
No
Modular version
No
Conductor material
Copper

Approvals

Product Standards
UL 506; UL5085-1; UL 5085-2; CSA-C22.2 No. 66; CSA-C22.2 No. 66.1-06; CSA-C22.2 No. 66.2-06; IEC/EN 61558-2-2; CE marking
UL File No.
E167225
UL Category Control No.
XPTQ2, XPTQ8
CSA File No.
UL report applies to both US and Canada
CSA Class No.
North America Certification
UL recognized, certified by UL for use in Canada
Specially designed for North America
No
Suitable for
Branch circuits
Max. Voltage Rating
600 V AC
Degree of Protection
IEC: IP00, UL/CSA Type: -

Dimensions

390X092
① Connection lugs
② With STI/STZ0.06 … 0.16 ground connection at bottom
③ The higher rated operating voltage applies

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.