STZ0,2(*/*) 914764 EATON ELECTRIC Control transformer, 200VA, 1p, non-standard voltage View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

STZ0,2(*/*) 914764 EATON ELECTRIC Control transformer, 200VA, 1p, non-standard voltage

STZ0,2(*/*)

914764

-

EATON-MOELLER

Control transformer, 200VA, 1p, non-standard voltage

STZ0,2(*/*)

Control transformer, 0.2 kVA, Rated input voltage 50 – 950 ± 5 % V, Rated output voltage 12 – 1000 V

More details


Low-voltage industrial components > One-phase control transformer

Transformers

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $182.19
Unit price: $182.19

Quantity Price
1+$182.19
2+$158.70
3+$157.03
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Control transformer, 0.2 kVA, Rated input voltage 50 – 950 ± 5 % V, Rated output voltage 12 – 1000 V
Control transformer, Product range: Single-phase control transformers ST..., Basic function: Single-phase control, isolating and safety transformers STI, STZ, Rated input voltage: 50 – 950 ± 5 % V, Rated output voltage: 12 – 1000 V, Rated power: 0.2 kVA, Short-time rating: 0.44 kVA, Degree of Protection: IP00, Standards Built and tested to: IEC/EN 61558-2-2/2-4/2-6, VDE 0570 Part 2-2, VDE 0570 Part 2‐6 (safety transformers), VDE 0570 Part 2-4 (isolating transformer), Suitable for use to: IEC/EN 60204-1, ÖVE-EN 13, VDE 0113, VDE 0100 Part 410

General specifications
Product name
Eaton Moeller® series STZ Control transformer
Part no.
STZ0,2(*/*)
Product Length/Depth
83 millimetre
Product height
112 millimetre
Product width
106 millimetre
Product weight
3 kilogram
Certifications
UL Category Control No.: XPTQ2, XPTQ8
UL Recognized
UL File No.: E167225
VDE 0570 Part 2-2
VDE 0570 Part 2‐6 (safety transformers)
CSA-C22.2 No. 66.1-06
CSA-C22.2 No. 66
CSA-C22.2 No. 66.2-06
IEC/EN 60204-1, ÖVE-EN 13
UL report applies to both US and Canada
UL5085-1
Certified by UL for use in Canada
VDE 0113, VDE 0100 Part 410
UL 506
IEC/EN 61558-2-2
CE
IEC/EN 61558-2-2/2-4/2-6
UL 5085-2
VDE 0570 Part 2-4 (isolating transformer)
Product Tradename
STZ
Product Type
Control transformer
Product Sub Type
None
Catalog Notes
Electrical characteristics: all details for no-load loss, short-circuit loss (copper losses), short-circuit voltage and efficiency values relate to a temperature of 20 °C
Features & Functions
Features
Fully Vacuum-impregnated
Reinforced insulation
Separate windings
General information
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
40 °C
Connection lug
Yes for < 63 A
Connection type
Terminations, < 63 A
Degree of protection
IP00
Duty factor
100 %
Insulation class
B
Primary tapping
± 5 %
Product category
Single-phase control transformers ST
Suitable for
Branch circuits, (UL/CSA)
Type
Single-phase control, isolating and safety transformer
Electrical rating
Efficiency
88 %
No-load losses
11 W
Rated frequency - min
50 Hz
Rated frequency - max
60 Hz
Rated power
0.2 V·A
Relative short-circuit voltage
6.6 %
Short-circuit losses
17 W
Short-time rating
0.44 kV·A
Voltage rating - max
600 V
Design verification
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
28 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 9.0

Low-voltage industrial components (EG000017) / One-phase control transformer (EC002486)
Electric engineering, automation, process control engineering / Transformer, converter, coil / Control transformer / One-phase control transformer (ecl@ss13-27-03-13-02 [AAB620020])
Built as safety transformer
Yes
Built as isolating transformer
Yes
Built as energy saving transformer
No
Primary voltage 1
50 - 950 V
Primary voltage 2
50 - 950 V
Primary voltage 3
50 - 950 V
Primary voltage 4
50 - 950 V
Primary voltage 5
50 - 950 V
Primary voltage 6
50 - 950 V
Primary voltage 7
0 - 0 V
Primary voltage 8
0 - 0 V
Primary voltage 9
0 - 0 V
Primary voltage 10
0 - 0 V
Secondary voltage 1
12 - 1000 V
Secondary voltage 2
12 - 1000 V
Secondary voltage 3
12 - 1000 V
Secondary voltage 4
12 - 1000 V
Secondary voltage 5
12 - 1000 V
Secondary voltage 6
12 - 1000 V
Secondary voltage 7
0 - 0 V
Secondary voltage 8
0 - 0 V
Secondary voltage 9
0 - 0 V
Secondary voltage 10
0 - 0 V
Rated apparent power
200 VA
Power
W
Power consumption in standby mode
6 W
Type of insulation material according to IEC 85
B
Short-circuit-proof
No
Relative short circuit voltage
6.6 %
Width
106 mm
Height
112 mm
Depth
83 mm
Degree of protection (IP)
IP00
Ring core
No
Suitable for mounting on PCB
No
Modular version
No
Conductor material
Copper

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.