DILMP20(600V60HZ)

276965

XTCF020B00D

EATON-MOELLER

010093 DILER-31(600V60HZ)

Power Contactor Screw Connection 4 Poles 20 A AC-1 600 V 60

Contactor, 4 pole, 22 A, 600 V 60 Hz, AC operation

More details


Low-voltage industrial components > Power contactor, AC switching

Contactors up to 170A

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Contactor, 4 pole, 22 A, 600 V 60 Hz, AC operation
Contactor, Application: Contactors for 4 pole electric consumers, Contactors up to 200 A, 4 pole, Utilization category: AC-1: Non-inductive or slightly inductive loads, resistance furnaces, NAC-3: Normal AC induction motors: starting, switch off during running, Connection technique: Screw terminals, Number of poles: 4 pole, 380 V 400 V: Ie= 12 A, Conventional free air thermal current, 3 pole, 50 - 60 Hz Open at 40 °C: Ith =Ie= 22 A, enclosed: Ith= 18 A, Conventional free air thermal current, 1 pole open: Ith= 60 A, enclosed: Ith= 54 A, 220 V 230 V: P= 3.5 kW, 380 V 400 V: P= 5.5 kW, 660 V 690 V: P= 6.5 kW, Instructions: Contacts to EN 50 012., Voltage AC/DC: AC operation

Delivery program

Product range
Contactors
Application
Contactors for 4 pole electric consumers
Subrange
Contactors up to 200 A, 4 pole
Utilization category
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
AC-3/AC-3e: Normal AC induction motors: Starting, switching off while running
Connection technique
Screw terminals
Number of poles
4 pole
Rated operational current
AC-1Conventional free air thermal current, 3 pole, 50 - 60 Hzat 40 °C [Ith=Ie]
22 A
AC-1Conventional free air thermal current, 3 pole, 50 - 60 Hzat 50 °C [Ith=Ie]
21 A
AC-1Conventional free air thermal current, 3 pole, 50 - 60 Hzat 55 °C [Ith=Ie]
20.5 A
AC-1Conventional free air thermal current, 3 pole, 50 - 60 Hzat 60 °C [Ith=Ie]
20 A
Contact sequence
210S028
For use with
DILM32-XHI(C)…
DILA-XHI(V)(C)…
Actuating voltage
600 V 60 Hz
Voltage AC/DC
AC operation
Connection to SmartWire-DT
no
Instructions
Contacts to EN 50 012.

Technical data

General
Standards
IEC/EN 60947, VDE 0660, UL, CSA
Lifespan, mechanicalAC operated [Operations]
10 x 106
Lifespan, mechanicalDC operated [Operations]
10 x 106
Operating frequency, mechanicalAC operated [Operations/h]
5000
Operating frequency, mechanicalDC operated [Operations/h]
5000
Climatic proofing
Damp heat, constant, to IEC 60068-2-3
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperatureOpen
-25 - +60 °C
Ambient temperatureEnclosed
- 25 - 40 °C
Ambient temperatureStorage
- 40 - 80 °C
Mounting positionMounting position
210N017210N018
Mechanical shock resistance (IEC/EN 60068-2-27)Half-sinusoidal shock, 10 msMain contactsN/O contact
10 g
Mechanical shock resistance (IEC/EN 60068-2-27)Half-sinusoidal shock, 10 msAuxiliary contactsN/O contact
7 g
Mechanical shock resistance (IEC/EN 60068-2-27)Half-sinusoidal shock, 10 msAuxiliary contactsN/C contact
5 g
Degree of Protection
IP20
Altitude
Max. 2000 m
Protection against direct contact when actuated from front (EN 50274)
Finger and back-of-hand proof
Stripping length
10 mm
Terminal capacity main cableSolid
1 x (0.75 - 4)
2 x (0.75 - 2.5) mm2
Terminal capacity main cableFlexible with ferrule
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Terminal capacity main cableSolid or stranded
18 - 14 AWG
Terminal capacity main cableTerminal screw
M3.5
Terminal capacity main cableTightening torque
1.2 Nm
Terminal capacity main cableStripping length
10 mm
Terminal capacity main cablePush-in terminalsSolid
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Terminal capacity main cablePush-in terminalsflexible
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Terminal capacity main cablePush-in terminalsflexible with ferrules
1 x (0.75 - 1.5)
2 x (0.75 - 1.5) mm2
Terminal capacity main cablePush-in terminalsSolid or stranded
18 - 14 AWG
Terminal capacity control circuit cablesSolid
1 x (0.75 - 4)
2 x (0.75 - 2.5) mm2
Terminal capacity control circuit cablesFlexible with ferrule
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Terminal capacity control circuit cablesSolid or stranded
18 - 14 AWG
Terminal capacity control circuit cablesStripping length
10 mm
Terminal capacity control circuit cablesTerminal screw
M3.5
Terminal capacity control circuit cablesTightening torque
1.2 Nm
Terminal capacity control circuit cablesPush-in terminalsSolid
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Terminal capacity control circuit cablesPush-in terminalsFlexible
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Terminal capacity control circuit cablesPush-in terminalsFlexible with ferrule
1 x (0.75 - 1.5)
2 x (0.75 - 1.5) mm2
Terminal capacity control circuit cablesPush-in terminalsSolid or stranded
18 - 14 AWG
ToolMain cablePozidriv screwdriver
2 Size
ToolMain cableStandard screwdriver
0.8 x 5.5
1 x 6 mm
ToolControl circuit cablesPozidriv screwdriver
2 Size
ToolControl circuit cablesStandard screwdriver
0.8 x 5.5
1 x 6 mm
Main conducting paths
Rated impulse withstand voltage [Uimp]
8000 V AC
Overvoltage category/pollution degree
III/3
Rated insulation voltage [Ui]
690 V AC
Rated operational voltage [Ue]
690 V AC
Safe isolation to EN 61140between coil and contacts
400 V AC
Safe isolation to EN 61140between the contacts
400 V AC
Making capacity (cos ϕ) [Up to 690 V]
144
According to IEC/EN 60947 A
Breaking capacity220 V 230 V
120 A
Breaking capacity380 V 400 V
120 A
Breaking capacity500 V
100 A
Breaking capacity660 V 690 V
70 A
Short-circuit ratingShort-circuit protection maximum fuseType “2” coordination400 V [gG/gL 500 V]
20 A
Short-circuit ratingShort-circuit protection maximum fuseType “2” coordination690 V [gG/gL 690 V]
20 A
Short-circuit ratingShort-circuit protection maximum fuseType “1” coordination400 V [gG/gL 500 V]
35 A
Short-circuit ratingShort-circuit protection maximum fuseType “1” coordination690 V [gG/gL 690 V]
25 A
AC
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 40 °C [Ith=Ie]
22 A
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 50 °C [Ith=Ie]
21 A
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 55 °C [Ith=Ie]
20.5 A
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 60 °C [Ith=Ie]
20 A
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 Hzenclosed [Ith]
18 A
AC-1Rated operational currentConventional free air thermal current, 1 poleopen [Ith]
60 A
AC-1Rated operational currentConventional free air thermal current, 1 poleenclosed [Ith]
54 A
AC-1Motor rating [P]220/230 V [P]
8 kW
AC-1Motor rating [P]240 V [P]
9 kW
AC-1Motor rating [P]380/400 V [P]
14 kW
AC-1Motor rating [P]415 V [P]
15 kW
AC-1Motor rating [P]440 V [P]
16 kW
AC-1Motor rating [P]500 V [P]
18 kW
AC-1Motor rating [P]690 V [P]
24 kW
AC-3Rated operational currentOpen, 3-pole: 50 – 60 HzNotes
At maximum permissible ambient temperature (open.)
Also tested according to AC-3e.
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz220 V 230 V [Ie]
12 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz240 V [Ie]
12 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz380 V 400 V [Ie]
12 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz415 V [Ie]
12 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz440V [Ie]
12 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz500 V [Ie]
10 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz660 V 690 V [Ie]
7 A
AC-3Motor rating [P]220 V 230 V [P]
3.5 kW
AC-3Motor rating [P]240V [P]
4 kW
AC-3Motor rating [P]380 V 400 V [P]
5.5 kW
AC-3Motor rating [P]415 V [P]
7 kW
AC-3Motor rating [P]440 V [P]
7.5 kW
AC-3Motor rating [P]500 V [P]
7 kW
AC-3Motor rating [P]660 V 690 V [P]
6.5 kW
DC
Rated operational current, openDC-160 V [Ie]
22 A
Rated operational current, openDC-1110 V [Ie]
22 A
Rated operational current, openDC-1220 V [Ie]
6 A
Current heat loss
3 pole, at Ith(60°)
3 W
Impedance per pole
2.5 mΩ
Magnet systems
Voltage toleranceAC operated 50 Hz [Pick-up]
0.8 - 1.1 x Uc
Voltage toleranceAC operated 50/60 Hz
0.8 - 1.1 x Uc
Voltage toleranceDrop-out voltage AC operated [Drop-out]
0.4 - 0.6 x Uc
Power consumption of the coil in a cold state and 1.0 x USAC operated 50/60 Hz [Pick-up]
24 VA
Power consumption of the coil in a cold state and 1.0 x USAC operated 50/60 Hz [Pick-up]
19 W
Power consumption of the coil in a cold state and 1.0 x USAC operated 50/60 Hz [Sealing]
4 VA
Power consumption of the coil in a cold state and 1.0 x USAC operated 50/60 Hz [Sealing]
1.4 W
Duty factor
100 % DF
Changeover time at 100 % US(recommended value)Main contactsAC operatedClosing delay
15 - 21 ms
Changeover time at 100 % US(recommended value)Main contactsAC operatedOpening delay
9 - 18 ms
Changeover time at 100 % US(recommended value)Permissible residual current with actuation of A1 - A2 by the electronics (with 0 signal).
≦ 1 mA

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
22 A
Heat dissipation per pole, current-dependent [Pvid]
1 W
Equipment heat dissipation, current-dependent [Pvid]
3 W
Static heat dissipation, non-current-dependent [Pvs]
1.4 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+60 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Power contactor, AC switching (EC000066)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Contactor (LV) / Power contactor, AC switching ([email protected] [AAB718015])
Rated control supply voltage Us at AC 50HZ
0 - 0 V
Rated control supply voltage Us at AC 60HZ
600 - 600 V
Rated control supply voltage Us at DC
0 - 0 V
Voltage type for actuating
AC
Rated operation current Ie at AC-1, 400 V
22 A
Rated operation current Ie at AC-3, 400 V
12 A
Rated operation power at AC-3, 400 V
5.5 kW
Rated operation current Ie at AC-4, 400 V
10 A
Rated operation power at AC-4, 400 V
4.5 kW
Rated operation power NEMA
0 kW
Modular version
No
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Screw connection
Number of normally closed contacts as main contact
0
Number of main contacts as normally open contact
4

Characteristics

2110CON-3
Accessories
1: Auxiliary contact module
2: Suppressor
Characteristic curve
2110DIA-3
Switching conditions for 4 pole, non-motor loads
Operating characteristics
Non inductive and slightly inductive loads
Electrical characteristics
Switch on: 1 x rated operational current
Switch off: 1 x rated operational current
Utilization category
100 % AC-1
Typical examples of application
Electric heat

Dimensions

2110DIM-8
Contactor with auxiliary contact module
2110DIM-9
DILMP20

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.