+NZM2-XKR4U 281665 EATON ELECTRIC Connection, on rear, 3.5mm, 3p, bottom View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

+NZM2-XKR4U 281665 EATON ELECTRIC Connection, on rear, 3.5mm, 3p, bottom

+NZM2-XKR4U

281665

EATON-MOELLER

Available Ship on today

These delivery times are estimations and may vary when the item order has been processed. You will be notified of any change to delivery times once the order has been processed.

Connection, on rear, 3.5mm, 3p, bottom

More details


Low-voltage industrial components > Wiring set for power circuit breaker

Circuit Breakers NZM Accessories

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $11.38
Unit price: $11.38

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Connection, on rear, 3.5mm, 3p, bottom
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. suffix and part no. contain parts for a circuit-breaker side at top or bottom for 3 or 4 pole circuit-breakers. O = for fitting at the top. U = for fitting at the bottom. Can be used for: NZM2, PN2, N(S)2

Delivery program

Ordering information
When ordering with basic device
Product range
60 mm system
Basic function
Connection block for component adapters
Accessories
Connection block
Number of poles
3 pole
Number of conductors
3 pole
for NZM3 component adapter
Rated operational current [Ie]
250 A
Cu factor
0,00 kg
For use with
NZM2,
PN2,
N(S)2
Mounting position
Fitted at the bottom
Notes

Required for component adapters and switches with connection on rear; see device adapters 104555 and 104556 for an example.

O = Mounted on top

U = Fitted at the bottom

Design verification as per IEC/EN 61439

IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Wiring set for power circuit breaker (EC002050)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Wiring set for circuit breaker ([email protected] [ACN957011])
Suitable for number of poles
3
Model
Other

Approvals

Product Standards
UL489; CSA-C22.2 No. 5-09; IEC60947-2, CE marking
UL File No.
E31593
UL Category Control No.
DIVQ
CSA File No.
022086
CSA Class No.
1432-01
North America Certification
UL listed, CSA certified
Specially designed for North America
Yes
Suitable for
Feeder circuits, branch circuits
Current Limiting Circuit-Breaker
Yes
Max. Voltage Rating
480Y/277 V
Degree of Protection
IEC: IP20; UL/CSA Type: -

Datasheet - PDF

Title: Size: Type:
+NZM2-XKR4U 281665 EN_281665.pdf 166 Kbytes   +NZM2-XKR4U  281665 EN_281665.pdf

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.