Product successfully added to your shopping cart
CLS6-C32/2
263685
EATON-MOELLER
1
Magneto 2p 32A C curve 6kA
Home > EATON - MOELLER
* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Technical specifications for verification of design | |||
Rated current job for indication of the power dissipated | In | Has | Thirty two |
Power dissipated per pole, according to the current | Pvid | W | Zero |
Power dissipated in the material, a function of the current | Pvid | W | 8.1 |
Power dissipated static, dependent on the current | Pvs | W | Zero |
Power emission of the power dissipated | Pve | W | Zero |
Temperature of use min. | °C | -25 | |
Working temperature max. | °C | Fifty five | |
linear by +1 °C causes a decrease of 0.5 % intensity of the eligible | |||
Certificate for IEC/EN 61439 | |||
10.2 Strength of materials and parts | |||
10.2.2 Resistance to corrosion | The requirements of the product standard are met. | ||
10.2.3.1 heat Resistance of the envelope | The requirements of the product standard are met. | ||
10.2.3.2 Resistance of insulating Materials to Heat normal | The requirements of the product standard are met. | ||
10.2.3.3 Resistance insulating Materials for outstanding Warmth | The requirements of the product standard are met. | ||
10.2.4 Resistance to UV | The requirements of the product standard are met. | ||
10.2.5 Elevation | Without object to the fact that the entire apparatus must be evaluated. | ||
10.2.6 shock Test | Without object to the fact that the entire apparatus must be evaluated. | ||
10.2.7 Inscriptions | The requirements of the product standard are met. | ||
10.3 Degree of protection of the envelope | Without object to the fact that the entire apparatus must be evaluated. | ||
10.4 isolation Distances and lines of flight | The requirements of the product standard are met. | ||
10.5 Protection against electric shock | Without object to the fact that the entire apparatus must be evaluated. | ||
10.6 Mounting hardware | Without object to the fact that the entire apparatus must be evaluated. | ||
10.7 electrical Circuits and connections internal | Under the responsibility of the tableautier. | ||
10.8 Connections for the conductors passed from the outside | Under the responsibility of the tableautier. | ||
10.9 Properties of isolation | |||
10.9.2 withstand Voltage at industrial frequency | Under the responsibility of the tableautier. | ||
10.9.3 there Voltage shock | Under the responsibility of the tableautier. | ||
10.9.4 Test envelope insulation | Under the responsibility of the tableautier. | ||
10.10 Warm-up | The calculation of the warm-up is under the responsibility of the tableautier. Eaton provides the data of the dissipated power of the devices. | ||
10.11 resistance to short-circuits | Under the responsibility of the tableautier. The specifications of the devices must be observed. | ||
10.12 electromagnetic Compatibility | Under the responsibility of the tableautier. The specifications of the devices must be observed. | ||
10.13 mechanical Operation | At the level of the device, the required conditions are met, to the extent the instructions of the installation manual (IT) are taken into account. |
characteristic of tripping | C | ||
number of poles (total) | Two | ||
number of poles-protected | Two | ||
current rating assigned | Has | Thirty two | |
rated voltage | V | Four hundred | |
breaking power assigned to Icn according to EN 60898 230 V | kA | Six | |
breaking power assigned to Icn according to EN 60898 400 V | kA | Six | |
breaking power assigned to Icu according to IEC 60947-2 230 V | kA | Zero | |
breaking power assigned to Icu according to IEC 60947-2 400 V | kA | Zero | |
type of voltage | CA | ||
class energy limited | Three | ||
frequency | Hz | 50 - 60 | |
a neutral conductor connected simultaneously | not | ||
suitable for in-wall installation | not | ||
overvoltage category | Three | ||
pollution degree | Two | ||
width in units of partition | Two | ||
mounting depth | mm | 70.5 | |
auxiliary devices possible | yes | ||
protection class (IP) | IP20 |
Title: | Size: | Type: |
---|---|---|
CLS6-C32/2 263685 263685.pdf | 137 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.