CLS6-C25
263660
EATON-MOELLER
1
Over current switch, 25A, 1p, type C characteristic
Home > EATON - MOELLER
* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Technical data for design verification | |||
Rated operational current for specified heat dissipation | In | A | 25 |
Heat dissipation per pole, current-dependent | Pvid | W | 0 |
Equipment heat dissipation, current-dependent | Pvid | W | 3 |
Static heat dissipation, non-current-dependent | Pvs | W | 0 |
Heat dissipation capacity | Pdiss | W | 0 |
Operating ambient temperature min. | °C | -25 | |
Operating ambient temperature max. | °C | 55 | |
linear, per +1 °C, results in a 0.5% reduction of current carrying capacity | |||
IEC/EN 61439 design verification | |||
10.2 Strength of materials and parts | |||
10.2.2 Corrosion resistance | Meets the product standard's requirements. | ||
10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. | ||
10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. | ||
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects | Meets the product standard's requirements. | ||
10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. | ||
10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.7 Inscriptions | Meets the product standard's requirements. | ||
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.4 Clearances and creepage distances | Meets the product standard's requirements. | ||
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. | ||
10.8 Connections for external conductors | Is the panel builder's responsibility. | ||
10.9 Insulation properties | |||
10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. | ||
10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. | ||
10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. | ||
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. | ||
10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. | ||
10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. | ||
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Circuit breakers and fuses (EG000020) / Miniature circuit breaker (MCB) (EC000042) | |||
Electric engineering, automation, process control engineering / Electrical installation, device / Miniature circuit breaker system (MCB) / Miniature circuit breaker (MCB) ([email protected] [AAB905011]) | |||
Release characteristic | C | ||
Number of poles (total) | 1 | ||
Number of protected poles | 1 | ||
Nominal rated current | A | 25 | |
Nominal rated voltage | V | 230 | |
Rated short-circuit breaking capacity Icn EN 60898 at 230 V | kA | 6 | |
Rated short-circuit breaking capacity Icn EN 60898 at 400 V | kA | 6 | |
Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V | kA | 0 | |
Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V | kA | 0 | |
Voltage type | AC | ||
Current limiting class | 3 | ||
Frequency | Hz | 50 - 60 | |
Concurrently switching N-neutral | No | ||
Suitable for flush-mounted installation | No | ||
Over voltage category | 3 | ||
Pollution degree | 2 | ||
Width in number of modular spacings | 1 | ||
Built-in depth | mm | 70.5 | |
Additional equipment possible | Yes | ||
Degree of protection (IP) | IP20 |
Title: | Size: | Type: |
---|---|---|
CLS6-C25 263660 263660.pdf | 128 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.