NZMB1-A32 280989 0004358977 EATON ELECTRIC Circuit-breaker, 3p, 32A View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

NZMB1-A32 280989 0004358977 EATON ELECTRIC Circuit-breaker, 3p, 32A

NZMB1-A32

280989

0004358977

EATON-MOELLER

Available Ship on today

Circuit-breaker, 3p, 32A

More details


Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection

Circuit Breakers NZM

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $262.94
Unit price: $262.94

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Circuit-breaker, 3p, 32A
Circuit-breaker NZM1, 3 pole, Switching capacity 400/415 V 50 Hz( Icu ): 25 kA, Rated current = rated uninterrupted current Rated current = rated uninterrupted current( In = Iu ): 32 A, Installation type: Fixed, Box terminal, Standard/Approval: IEC, Protective function: System and cable protection

Delivery program

Product range
Circuit-breaker
Protective function
System and cable protection
Standard/Approval
IEC
Installation type
Fixed
Release system
Thermomagnetic release
Construction size
NZM1
Number of poles
3 pole
Standard equipment
Box terminal
Switching capacity
400/415 V 50 Hz [Icu]
25 kA
Rated current = rated uninterrupted current [In= Iu]
Rated current = rated uninterrupted current [In= Iu]
32 A
Setting range
Overload trip[Ir]
25 - 32 A
Short-circuit releases[Irm]Non-delayed[Ii= Inx …]
350 A fixed
Short-circuit releases[Irm]min.
350 A

Technical data

General
Standards
IEC/EN 60947
Protection against direct contact
Finger and back of hand proof to VDE 0106 Part 100
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperatureAmbient temperature, storage
- 40 - + 70 °C
Ambient temperatureOperation
-25 - +70 °C
Mechanical shock resistance (10 ms half-sinusoidal shock) according to IEC 60068-2-27
20 (half-sinusoidal shock 20 ms) g
Safe isolation to EN 61140Between auxiliary contacts and main contacts
500 V AC
Safe isolation to EN 61140between the auxiliary contacts
300 V AC
Mounting position
Vertical and 90° in all directions
With XFI earth-fault release:
- NZM1, N1, NZM2, N2: vertical and 90° in all directions
with plug-in unit
- NZM1, N1, NZM2, N2: vertical, 90° right/left
with withdrawable unit:
- NZM3, N3: vertical, 90° right/left
- NZM4, N4: vertical
with remote operator:
- NZM2, N(S)2, NZM3, N(S)3, NZM4, N(S)4: vertical and 90° in all directions

Direction of incoming supply
as required
Degree of protectionDevice
In the operating controls area: IP20 (basic degree of protection)
Degree of protectionEnclosures
With insulating surround: IP40
With door coupling rotary handle: IP66
Degree of protectionTerminations
Tunnel terminal: IP10
Phase isolator and strip terminal: IP00
Other technical data (sheet catalogue)
Circuit-breakers
Rated current = rated uninterrupted current [In= Iu]
32 A
Rated surge voltage invariability [Uimp]Main contacts
6000 V
Rated surge voltage invariability [Uimp]Auxiliary contacts
6000 V
Rated operational voltage [Ue]
440 V AC
Overvoltage category/pollution degree
III/3
Rated insulation voltage [Ui]
690 V
Use in unearthed supply systems
≦ 440 V
Switching capacity
Rated short-circuit making capacity [Icm]240 V [Icm]
63 kA
Rated short-circuit making capacity [Icm]400/415 V [Icm]
53 kA
Rated short-circuit making capacity [Icm]440 V 50/60 Hz [Icm]
53 kA
Rated short-circuit breaking capacity Icn[Icn]Icu to IEC/EN 60947 test cycle O-t-CO [Icu]240 V 50/60 Hz [Icu]
30 kA
Rated short-circuit breaking capacity Icn[Icn]Icu to IEC/EN 60947 test cycle O-t-CO [Icu]400/415 V 50/60 Hz [Icu]
25 kA
Rated short-circuit breaking capacity Icn[Icn]Icu to IEC/EN 60947 test cycle O-t-CO [Icu]440 V 50/60 Hz [Icu]
25 kA
Rated short-circuit breaking capacity Icn[Icn]Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]240 V 50/60 Hz [Ics]
30 kA
Rated short-circuit breaking capacity Icn[Icn]Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]400/415 V 50/60 Hz [Ics]
25 kA
Rated short-circuit breaking capacity Icn[Icn]Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]440 V 50/60 Hz [Ics]
18.5 kA
Rated short-circuit breaking capacity Icn[Icn]
Maximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit-breaker.
Utilization category to IEC/EN 60947-2
A
Lifespan, mechanical(of which max. 50 % trip by shunt/undervoltage release) [Operations]
20000
Lifespan, electricalAC-1400 V 50/60 Hz [Operations]
7500
Lifespan, electricalAC-1415 V 50/60 Hz [Operations]
7500
Lifespan, electricalMax. operating frequency
120 Ops/h
Total break time at short-circuit
< 10 ms
Terminal capacity
Standard equipment
Box terminal
Optional accessories
Screw connection
Tunnel terminal
connection on rear
Round copper conductorBox terminalSolid
1 x (10 - 16)
2 x (6 - 16) mm2
Round copper conductorBox terminalStranded
1 x (10 - 70)3)
2 x (6-25) mm2
Round copper conductorBox terminal
3)Up to 95 mm² can be connected depending on the cable manufacturer.
Round copper conductorTunnel terminalSolid
1 x 16 mm2
Round copper conductorTunnel terminalStranded1-hole
1 x (25 - 95) mm2
Round copper conductorBolt terminal and rear-side connectionDirect on the switchSolid
1 x (10 - 16)
2 x (6 - 16) mm2
Round copper conductorBolt terminal and rear-side connectionDirect on the switchStranded
1 x (10 - 70)3)
2 x 25 mm2
Round copper conductorBolt terminal and rear-side connectionDirect on the switch
3)Up to 95 mm² can be connected depending on the cable manufacturer.
Al circular conductorTunnel terminalSolid
1 x 16 mm2
Al circular conductorTunnel terminalStrandedStranded
1 x (25 - 95) mm2
Al circular conductorBolt terminal and rear-side connectionDirect on the switchSolid
1 x (10 - 16)
2 x (10 - 16) mm2
Al circular conductorBolt terminal and rear-side connectionDirect on the switchStranded
1 x (25 - 35)
2 x (25 - 35) mm2
Cu strip (number of segments x width x segment thickness)Box terminal [min.]
2 x 9 x 0.8 mm
Cu strip (number of segments x width x segment thickness)Box terminal [max.]
9 x 9 x 0.8 mm
Copper busbar (width x thickness) [mm]Bolt terminal and rear-side connectionScrew connection
M6
Copper busbar (width x thickness) [mm]Bolt terminal and rear-side connectionDirect on the switch [min.]
12 x 5 mm
Copper busbar (width x thickness) [mm]Bolt terminal and rear-side connectionDirect on the switch [max.]
16 x 5 mm
Control cables
1 x (0.75 - 2.5)
2 x (0.75 - 1.5) mm2

Design verification as per IEC/EN 61439

Dane techniczne dla zaświadczenia rodzaju konstrukcji
Znamionowy prąd pracy do podania straty mocy [In]
32 A
Strata mocy elementu eksploatacyjnego, w zależności od prądu [Pvid]
9.31 W
Robocza temperatura otoczenia min.
-25 °C
Robocza temperatura otoczenia maks.
+70 °C
Certyfikat konstrukcji IEC/EN 61439
10.2 Wytrzymałość materiałów i części10.2.2 Odporność na korozję
Wymagania odnośnie normy produktowej zostały spełnione.
10.2 Wytrzymałość materiałów i części10.2.3.1 Wytrzymałość cieplna powłoki
Wymagania odnośnie normy produktowej zostały spełnione.
10.2 Wytrzymałość materiałów i części10.2.3.2 Rezystancja materiału izolacyjnego przy normalnym cieple
Wymagania odnośnie normy produktowej zostały spełnione.
10.2 Wytrzymałość materiałów i części10.2.3.3 Rezystancja materiału izolacyjnego przy nietypowym cieple
Wymagania odnośnie normy produktowej zostały spełnione.
10.2 Wytrzymałość materiałów i części10.2.4 Wytrzymałość na działanie promieniowania UV
Wymagania odnośnie normy produktowej zostały spełnione.
10.2 Wytrzymałość materiałów i części10.2.5 Podnoszenie
Nie dotyczy, ponieważ należy ocenić całą szafę sterowniczą.
10.2 Wytrzymałość materiałów i części10.2.6 Kontrola odporności na uderzenia
Nie dotyczy, ponieważ należy ocenić całą szafę sterowniczą.
10.2 Wytrzymałość materiałów i części10.2.7 Napisy
Wymagania odnośnie normy produktowej zostały spełnione.
10.3 Stopień ochrony powłok
Nie dotyczy, ponieważ należy ocenić całą szafę sterowniczą.
10.4 Odstępy izolacyjne powietrzne i prądów pełzających
Wymagania odnośnie normy produktowej zostały spełnione.
10.5 Ochrona przed porażeniem elektrycznym
Nie dotyczy, ponieważ należy ocenić całą szafę sterowniczą.
10.6 Montaż elementów eksploatacyjnych
Nie dotyczy, ponieważ należy ocenić całą szafę sterowniczą.
10.7 Wewnętrzne obwody prądowe i połączenia
Należy do zakresu odpowiedzialności wykonawcy szafy sterowniczej.
10.8 Przyłącza przewodów wchodzących z zewnątrz
Należy do zakresu odpowiedzialności wykonawcy szafy sterowniczej.
10.9 Właściwości izolacji10.9.2 Wytrzymałość elektryczna o częstotliwości roboczej
Należy do zakresu odpowiedzialności wykonawcy szafy sterowniczej.
10.9 Właściwości izolacji10.9.3 Odporność na napięcie udarowe
Należy do zakresu odpowiedzialności wykonawcy szafy sterowniczej.
10.9 Właściwości izolacji10.9.4 Sprawdzanie powłok z materiału izolacyjnego
Należy do zakresu odpowiedzialności wykonawcy szafy sterowniczej.
10.10 Nagrzanie
Oszacowanie nagrzania należy do zakresu odpowiedzialności wykonawcy szafy sterowniczej. Eator dostarczy danych na temat straty mocy aparatów.
10.11 Odporność na zwarcia
Należy do zakresu odpowiedzialności wykonawcy szafy sterowniczej. Przestrzegać wytycznych odnośnie aparatów łączeniowych.
10.12 Kompatybilność elektromagnetyczna
Należy do zakresu odpowiedzialności wykonawcy szafy sterowniczej. Przestrzegać wytycznych odnośnie aparatów łączeniowych.
10.13 Działanie mechaniczne
Spełnienie wymagań w aparacie jest jednoznaczne z przestrzeganiem instrukcji montażu (IL).

Technical data ETIM 7.0

Urządzenia niskonapięciowe (EG000017) / Wyłącznik do transformatorów, generatorów i zabezp. instalacji elektrycznej (EC000228)
Elektrotechnika, automatyzacja i technologia / Rozdzielnice niskonapięciowe / Wyłącznik mocy, odłącznik mocy (niskie napięcia) / Wyłącznik zabezpieczający transformatory, generatory i urządzenia ([email protected] [AJZ716013])
Znamionowy prąd ciągły Iu
32 A
Zakres napięcia znamionowego
440 - 440 V
Znamionowa zwarciowa zdolność łączeniowa lcu przy 400 V, 50 Hz
25 kA
Zakres nastawy wyzwalacza przeciążeniowego
25 - 32 A
Zakres nastawczy wyzwalacza zwarciowego zwłocznego
0 - 0 A
Zakres nastawy wyzwalacza zwarciowego
350 - 350 A
Zintegrowane zabezpieczenie przed zwarciem doziemnym
Nie
Rodzaj podłączenia styków głównych
Zacisk ramowy
Budowa urządzenia
Urządzenie mocowane na stałe
Do montażu na szynie TH
Nie
Opcjonalny montaż na szynie DIN TH
Tak
Liczba styków pomocniczych rozwiernych
0
Liczba styków pomocniczych zwiernych
0
Liczba styków pomocniczych przełącznych
0
Ze wskaźnikiem wyłączenia
Nie
Z wyzwalaczem podnapięciowym
Nie
Liczba biegunów
3
Umiejscowienie przyłączy obwodów głównych
Strona przednia
Rodzaj elementu wykonawczego
Dźwignia
W komplecie z zabezpieczeniem
Tak
Wbudowany napęd silnikowy
Nie
Opcjonalny napęd silnikowy
Nie
Stopień ochrony (IP)
IP20

Characteristics

Characteristic curve
123U177
Characteristic curve
1230DIA-58
Let-through current
Characteristic curve
1230DIA-51
Let-through energy

Dimensions

123X039
① Blow out area, minimum clearance to adjacent parts
123X506

Datasheet - PDF

Title: Size: Type:
NZMB1-A32 0004358977 280989 EN_280989.pdf 575 Kbytes   NZMB1-A32 0004358977 280989 EN_280989.pdf

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.