C445MC-136V 181575 EATON ELECTRIC Measuring module, 90mm, 17-136 A, for voltage measurement

C445MC-136V

181575

EATON-MOELLER

Measuring module, 90mm, 17-136 A, for voltage measurement

Module measurement; 90 mm; 17-136 To; For voltage measurement

More details


Thermal Relays

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Measuring module, 90mm, 17-136 A, for voltage measurement
Alternate Catalog No.
C445MC-136V
Intelligent motor management system C445 measuring module, 90mm, 17-136 A, for voltage measurement
[

Delivery program

Product range
Measurement modules
Basic function
Current measurement
Voltage measurement
Current range
17 - 136 A
Mounting width
90 mm
,

Technical data

General
Standards
IEC/EN 60947-4-1, UL 60947-4-1
Ambient temperatureOpen
-40 - +60 °C
Mounting position
As required
Mechanical shock resistance
15
Shock duration 11 ms
non-operating g
Degree of Protection
IP20
Main conducting paths
Rated insulation voltage [Ui]
110 - 690 V AC
Short-circuit protection max. fuse gL-characteristic
400 A gL
Current heat loss (3 conductors)Maximum setting
5 W
Push-through opening [⌀]
15.9 mm
Rating data for approved types
Short Circuit Current RatingBasic RatingSCCR
10 kA
Short Circuit Current RatingBasic Ratingmax. Fuse
400 A
Short Circuit Current RatingBasic Ratingmax. CB
400 A
Short Circuit Current Rating480 V High FaultSCCR (fuse)
100 kA
Short Circuit Current Rating480 V High Faultmax. Fuse
400 A
Short Circuit Current Rating480 V High FaultSCCR (CB)
100 kA
Short Circuit Current Rating480 V High Faultmax. CB
400 A
Short Circuit Current Rating600 V High FaultSCCR (fuse)
100 kA
Short Circuit Current Rating600 V High Faultmax. Fuse
400 A
Short Circuit Current Rating600 V High FaultSCCR (CB)
50 kA
Short Circuit Current Rating600 V High Faultmax. CB
400 A
,

Design verification as per IEC/EN 61439

Static heat dissipation, non-current-dependent [Pvs]
5 W
Operating ambient temperature min.
-40 °C
Operating ambient temperature max.
+60 °C
,

Approvals

Product Standards
IEC/EN 60947-4-1; UL 508; CSA C22.2 No. 14; CE marking
UL File No.
E1230
UL Category Control No.
NKCR
North America Certification
UL listed, CSA certified
Specially designed for North America
No
,

Dimensions

]

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.