DILA-XHIC20 276528 XTCEXFACC20 EATON ELECTRIC Auxiliary contact module, 2N/O, surface mounting, spring clamp.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DILA-XHIC20 276528 XTCEXFACC20 EATON ELECTRIC Auxiliary contact module, 2N/O, surface mounting, spring clamp..

DILA-XHIC20

276528

XTCEXFACC20

EATON-MOELLER

5

Auxiliary contact module, 2N/O, surface mounting, spring clamp connection

Auxiliary contact module, 2 pole, Ith= 16 A, 2 N/O, Front fixing, Spring-loaded terminals, DILA, DILM7 - DILM38

More details


Low-voltage industrial components > Auxiliary contact block

KDIL Accessories

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



EL-Nummer (Norway)
4110269
Auxiliary contact module, 2 pole, Ith= 16 A, 2 N/O, Front fixing, Spring-loaded terminals, DILA, DILM7 - DILM38
Auxiliary contact module, with interlocked opposing contacts, Switching elements according to EN 50005, Version E combinations correspond to EN 50011 and are to be preferred., The DC operated contactor DILA(C)-22 must only be combined with 2-pole auxiliary contacts., Function: for standard applications, 2 pole, Connection technique: Spring-loaded terminals, Rated operational current AC-15 220 V 230 V 240 V: Ie= 4 A, Rated operational current AC-15 380 V 400 V 415 V: Ie= 4 A, Contacts N/O = Normally open: 2 N/O, Mounting type: Front fixing, For use with: DILA(C)…, DILM(C)7…, DILM(C)9…, DILM(C)12…, DILM(C)15…, DILM(C)17…, DILM(C)25…, DILM(C)32…, DILM38…, DILMP20…, DILMP32…, DILMP45…, DILL…, DILMF8…, DILMF11…, DILMF14…, DILMF17…, DILMF25…, DILMF32…, Type: Front mounting auxiliary contact, Instructions: Interlocked opposing contacts according to IEC/EN 60947-5-1 appendix L, inside the auxiliary contact modules, also for the integrated auxiliary contacts of the DILM 7 - DILM32, Auxiliary contacts used as mirror contacts according to IEC/EN 60947-4-1 Appendix F (not N/C late open), Code number and version of combination Distinctive number: 60E, 51, 42

Delivery program

Accessories
Auxiliary contact modules
Description
with interlocked opposing contacts
Switching elements according to EN 50005
Version E combinations correspond to EN 50011 and are to be preferred.
The DC operated contactor DILA(C)-22 must only be combined with 2-pole auxiliary contacts.
Function
for standard applications
Number of poles
2 pole
Connection technique
Spring-loaded terminals
Rated operational current
Conventional free air thermal current, 1 poleOpenat 60 °C [Ith]
16 A
AC-15220 V 230 V 240 V [Ie]
4 A
AC-15380 V 400 V 415 V [Ie]
4 A
Contacts
N/O = Normally open
2 N/O
Mounting type
Front fixing
Contact sequence
210S034
For use with
DILA(C)…
DILM(C)7…
DILM(C)9…
DILM(C)12…
DILM(C)15…
DILM(C)17…
DILM(C)25…
DILM(C)32…
DILM38…
DILMP20…
DILMP32…
DILMP45…
DILL…
DILMF8…
DILMF11…
DILMF14…
DILMF17…
DILMF25…
DILMF32…
Type
Front mounting auxiliary contact
Instructions
Interlocked opposing contacts according to IEC/EN 60947-5-1 appendix L, inside the auxiliary contact modules, also for the integrated auxiliary contacts of the DILM 7 - DILM32
Auxiliary contacts used as mirror contacts according to IEC/EN 60947-4-1 Appendix F (not N/C late open)
Code number and version of combination
Distinctive number
60E
with basic device
DILA(C)-40
51
with basic device
DILA(C)-31
42
with basic device
DILA(C)-22

Technical data

General
Standards
IEC/EN 60947, VDE 0660, UL, CSA
Lifespan, mechanicalAC operated [Operations]
10 x 106
Lifespan, mechanicalDC operated [Operations]
10 x 106
Component lifespanat Ue= 230 V, AC-15, 3 A [Operations]
1.3 x 106
Maximum operating frequency [Operations/h]
9000
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperatureOpen
-25 - +60 °C
Ambient temperatureEnclosed
- 25 - 40 °C
Ambient temperatureAmbient temperature, storage
- 40 - 80 °C
Mounting positionMounting position
210N017
Mechanical shock resistance (IEC/EN 60068-2-27)Half-sinusoidal shock, 10 msBasic unit with auxiliary contact moduleN/O contact
7 g
Mechanical shock resistance (IEC/EN 60068-2-27)Half-sinusoidal shock, 10 msBasic unit with auxiliary contact moduleN/C contact
5 g
Degree of Protection
IP20
Protection against direct contact when actuated from front (EN 50274)
Finger and back-of-hand proof
Weight
0.045 kg
Terminal capacitiesScrew terminalsTerminal screw
M3.5
Terminal capacitiesSpring-loaded terminalsFlexible with ferrule
1 x (0.75 - 1.5)
2 x (0.75 - 1.5) mm2
Terminal capacitiesSpring-loaded terminalsSolid or stranded
18 – 14 AWG
Terminal capacitiesSpring-loaded terminalsStandard screwdriver
0.6 x 3.5 mm
Contacts
Interlocked opposing contacts within an auxiliary contact module (to IEC 60947-5-1 Annex L)
Yes
N/C contact (not late-break contact) suitable as a mirror contact (to IEC/EN 60947-4-1 Annex F)
DILM7 - DILM32
Rated impulse withstand voltage [Uimp]
6000 V AC
Overvoltage category/pollution degree
III/3
Rated insulation voltage [Ui]
690 V AC
Rated operational voltage [Ue]
500 V AC
Safe isolation to EN 61140between coil and auxiliary contacts
400 V AC
Safe isolation to EN 61140between the auxiliary contacts
400 V AC
Rated operational currentConventional free air thermal current, 1 poleat 60 °C [Ith]
16 A
Rated operational currentAC-15220 V 230 V 240 V [Ie]
4 A
Rated operational currentAC-15380 V 400 V 415 V [Ie]
4 A
Rated operational currentAC-15500 V [Ie]
1.5 A
Rated operational currentDC current
Switch-on and switch-off conditions based on DC-13, time constant as specified.
Rated operational currentDC currentDC L/R ≦ 15 msContacts in series:1 [24 V]
10 A
Rated operational currentDC currentDC L/R ≦ 15 msContacts in series:1 [60 V]
6 A
Rated operational currentDC currentDC L/R ≦ 15 msContacts in series:2 [60 V]
10 A
Rated operational currentDC currentDC L/R ≦ 15 msContacts in series:1 [110 V]
3 A
Rated operational currentDC currentDC L/R ≦ 15 msContacts in series:3 [110 V]
6 A
Rated operational currentDC currentDC L/R ≦ 15 msContacts in series:1 [220 V]
1 A
Rated operational currentDC currentDC L/R ≦ 15 msContacts in series:3 [220 V]
5 A
Rated operational currentDC currentDC L/R ≦ 50 msContacts in series:3 [24 V]
2.5 A
Rated operational currentDC currentDC L/R ≦ 50 msContacts in series:3 [60 V]
1 A
Rated operational currentDC currentDC L/R ≦ 50 msContacts in series:3 [110 V]
0.5 A
Rated operational currentDC currentDC L/R ≦ 50 msContacts in series:3 [220 V]
0.25 A
Rated operational currentDC currentDC-13 (6xP)24 V [Ie]
2.5 A
Rated operational currentDC currentDC-13 (6xP)60 V [Ie]
1 A
Rated operational currentDC currentDC-13 (6xP)110 V [Ie]
0.5 A
Rated operational currentDC currentDC-13 (6xP)220 V [Ie]
0.25 A
Rated operational currentControl circuit reliability [Failure rate]
<10-8, < one failure at 100 million operations
(at Ue= 24 V DC, Umin= 17 V, Imin= 5.4 mA) λ
Short-circuit rating without weldingShort-circuit protection maximum fuse500 V
10 A gG/gL
Current heat loss at IthAC operated
2.6 W
Current heat loss at IthDC operated
2.6 W
Current heat loss at IthCurrent heat loss per auxiliary circuit at Ie(AC-15/230 V)
0.16 CO
Rating data for approved types
Auxiliary contactsPilot DutyAC operated
A600
Auxiliary contactsPilot DutyDC operated
P300
Auxiliary contactsGeneral UseAC
600 V
Auxiliary contactsGeneral UseAC
10 A
Auxiliary contactsGeneral UseDC
250 V
Auxiliary contactsGeneral UseDC
1 A

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
4 A
Heat dissipation per pole, current-dependent [Pvid]
0.16 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+60 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Auxiliary contact block (EC000041)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Component for low-voltage switching technology / Auxiliary switch block ([email protected] [AKN342013])
Number of contacts as change-over contact
0
Number of contacts as normally open contact
2
Number of contacts as normally closed contact
0
Number of fault-signal switches
0
Rated operation current Ie at AC-15, 230 V
4 A
Type of electric connection
Spring clamp connection
Model
Top mounting
Mounting method
Front fastening
Lamp holder
None

Approvals

Product Standards
IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking
UL File No.
E29184
UL Category Control No.
NKCR
CSA File No.
012528
CSA Class No.
3211-03
North America Certification
UL listed, CSA certified
Specially designed for North America
No

Dimensions

210X201
Contactor with auxiliary contact module
210T013

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.