AFDD-25/2/B/003-LI/A 187226 DXA-EXT-ENCOD EATON ELECTRIC Switch fault electric arc, 2-pole, B25A, 30mA, type.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

AFDD-25/2/B/003-LI/A 187226 DXA-EXT-ENCOD EATON ELECTRIC Switch fault electric arc, 2-pole, B25A, 30mA, type..

AFDD-25/2/B/003-LI/A

187226

DXA-EXT-ENCOD

EATON-MOELLER

Switch fault electric arc, 2-pole, B25A, 30mA, type LI/A

Arc flash fault switch, 2-pole, B25A, 30mA, type LI/A

Arc Fault Detection Device, 2p, B, 25 A, 30 mA, type LI/A

More details


Circuit breakers and fuses > Earth leakage circuit breaker with auxiliary device

Modular Switchgear – Tertiary and Differential

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



EL-Nummer (Norway)
1601446
Arc Fault Detection Device, 2p, B, 25 A, 30 mA, type LI/A
Arc Fault Detection Device (AFDD) with residual current device/miniature circuit breaker combination, conforms to IEC/EN 62606, reliably detects arc faults, residual current circuit-breaker part is line voltage-independent, optionally pulse-current sensitive, delayed or non-delayed, contact position indicator red - green, trip indication with LED, terminal rear plug protection, tri-stable slide catch - enables removal from existing busbar system, comprehensive range of accessories suitable for subsequent installation, rated fault currents: 10 mA or 30 mA, rated operational currents up to 40 A, tripping characteristics B, C, rated breaking capacity up to 10 kA, suitable for outdoor use (on-site power and outdoor distribution board) up to -25 °C

Delivery program

Basic function
Arc fault detection device
Number of poles
2 pole
Tripping characteristic
B
Application
Switchgear for residential and commercial applications
Rated current [In]
25 A
Rated switching capacity according to IEC/EN 60898-1 [Icn]
10 kA
Rated switching capacity according to IEC/EN 61009
10 kA
Rated short-circuit strength [Icn]
10 kA
Rated fault current [IΔN]
0.03 A
Type
Typ LI/A
Tripping
Short time-delayed s…
Busbar type
ZV-SS
Product range
AFDD
Sensitivity
Pulse-current sensitive
Impulse withstand current
Partly surge-proof 250 A

Technical data

Electrical
Types conform to
IEC/EN 62606
IEC/EN 61009
Current test marks
As per inscription
Rated switching capacity according to IEC/EN 60898-1 [Icn]
10 kA
Limit values of the operating voltageTest circuit
170 - 264 V AC
Sensitivity
Pulse-current sensitive
Rated short-circuit strength [Icn]
10 kA
lifespanElectrical [Operations]
≧ 4000
lifespanMechanical [Operations]
≧ 20000
Mechanical
Standard front dimension
45 mm
Device height
80 mm
Built-in width
54 (3TE) mm
Mounting
Tristable slide catch enables removal from existing combination.
Degree of Protection
IP20 switches
IP40 enclosed
Terminals top and bottom
Twin-purpose terminals
Terminal protection
Busbar tag shroud as per VBG4, ÖVE-EN 6
Thickness of busbar material
0.8 - 2 mm
Admissible ambient temperature range
-25 - +40 °C
Permissible storage and transport temperatures
-35 - +60 °C
Climatic proofing
according to IEC/EN 61009
Contact position indicator
red / green

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
25 A
Equipment heat dissipation, current-dependent [Pvid]
6 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+40 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / Earth leakage circuit breaker with auxiliary device (EC002695)
Electric engineering, automation, process control engineering / Electrical installation, device / Residual current protection system / Earth leakage circuit breaker with auxiliary device ([email protected] [ADI479007])
Number of poles
2
Rated voltage
230 V
Rated current
25 A
Rated fault current
0.03 A
Leakage current type
A
Current limiting class
3
Rated short-circuit breaking capacity acc. EN 61009
6 kA
Rated short-circuit breaking capacity IEC 60947-2
0 kA
Frequency
50 Hz
Release characteristic
B
Concurrently switching N-neutral
No
Over voltage category
3
Pollution degree
2
Width in number of modular spacings
3
Built-in depth
67 mm
Additional equipment attached at delivery
Fire protection switch
Rated switch current auxiliary device
0 A
Rated voltage auxiliary device
230 V
Control voltage type auxiliary equipment
AC
Degree of protection (IP)
IP20

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.