RSE2312-BS CARLO GAVAZZI Selected parameters SYSTEM Soft Starter LOAD Phase 1 HOUSING WIDTH 22.5mm to 45mm.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

RSE2312-BS CARLO GAVAZZI Selected parameters SYSTEM Soft Starter LOAD Phase 1 HOUSING WIDTH 22.5mm to 45mm..

RSE2312-BS

CARLO GAVAZZI

Available Ship on today

Selected parameters SYSTEM Soft Starter LOAD Phase 1 HOUSING WIDTH >22.5mm to 45mm MOTOR RATING Up to 3kW LOAD CURRENT >10A to 25A CONTROLLED PHASES 1-Phase MAX NUMBER OF STATS PER HOUR >10 to 20 Others LOAD (result) Soft starter for 1-phase induction motors LOAD CURRENT 12A AC MAX MOTOR RATING 2 kW OPERATIONAL VOLTAGE 195-264V Acrms DIMENSIONS 91.7 x 45 x 102 mm CONTROLLED PHASES 1-Phase MAX NUMBER OF STATS PER HOUR 19

More details


Softstarters Soft Starters Motor

Switches

Soft Starters

* Brand new product in its original packaging covered by the warranties and certifications provided by CARLO GAVAZZI

Quantity Price
1+$178.85
2+$172.93
3+$170.09
4+$168.32
5+$167.24
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Motor Controllers, Single Phase
3-Phase Torque Reduction
Types RSE 1112-BS, RSE 2312-BS, RSE 4012-BS
• Rated operational current: 12 AAC 53 b
• Soft starting of most single phase motors
• Torque reduction by use on 3-phase motors
• Rated operational voltage: Up to 400 VAC, 50/60 Hz
• LED-indications for supply and operation
• Transient overvoltage protection built-in
• Integral bypassing of semiconductor
Product Description
Ordering Key
RSE 23 12 - BS
Compact easy-to-use AC semiconductor motor con- troller. With this controller sin- gle phase capacitor run induction motors with nominal load currents up to 12 A can be soft-started.Starting time as well as initial torque can be
independently adjusted by built-in potentiometers.
Torque reduction by ramping of a single phase in 3-phase applications is also possible with this module.
Solid State Relay Motor controller E-line housing
Rated operational voltage Rated operational current Control voltage
Single Phase Control
Type Selection
Rated operationalControl voltageRated operational current Ie
voltage UeUc 12 A
11: 115 VACrms, 50/60 Hz -B: 24 to 110 VAC/DC RSE 1112-BS
23: 230 VACrms, 50/60 Hz& 110 to 480 VACRSE 2312-BS
40: 400 VACrms, 50/60 HzRSE 4012-BS
InputSpecifications(Control Input)
Control voltage Uc
A1-A2: 24 - 110 VAC/DC ±15%,
12 mA
A1-A3: 110 - 480 VAC ±15%,
5 mA
Rated insulation voltage 630 V rms
Overvoltage cat. III (IEC 60664)
Dielectric strength
Dielectric voltage2.5 kVAC (rms) Rated impulse withstand volt. 4 kV (1.2/50 µs)
Output Specifications
Utilization category AC-53b Integral bypassing of semiconductors
Overload current profile
(overload relay trip class) 12A: AC-53b: 3-5: 180
Max. number of soft startingsStartings TAInactive per hour (at max. current for 5 s)
19 25ºC 180 s
15 30ºC 225 s
11 40ºC 315 s
Min. load current
RSE ..12-BS 200 mAAC rms
Specifications are subject to change without notice (30.03.2007)1

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.