BH4-RO5ADC2-230 BH4RO5ADC2230 CARLO GAVAZZI Selected parameters Others TYPE Roller Blind module HOUSING H4 (.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

BH4-RO5ADC2-230 BH4RO5ADC2230 CARLO GAVAZZI Selected parameters Others TYPE Roller Blind module HOUSING H4 (..

BH4-RO5ADC2-230

BH4RO5ADC2230

CARLO GAVAZZI

Available

Ship on today

Selected parameters Others TYPE Roller Blind module HOUSING H4 (W72) POWER SUPPLY 230 VAC MAIN CHARACTERISTICS Rollerblind module for up/down control of two 24 VDC rollerblind motors

More details


Home Smart Intelligent Building Automation

Fieldbuses

Home and Building Automation Systems

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

Related products

More info



Output Modules for Rollerblind Motors
BH4-RO5ADC2-230
Up/down control of 2 rollerblind motors
H4-housing
For mounting on DIN-rail (EN 50022)
LED-indications for supply smart-house carrier and motor up/down
AC power supply
Channel coding by BGP-COD-BAT
OUTPUT SPECIFICATIONS
Outputs2 SPST x 2 DPDT relays
Resistive loadsDC 13 5 A/24 VDC Mechanical lifetime ≥ 1 x 106 operations Electrical lifetime
(at max load) ≥ 1 x 105 operations
Operating frequency≤ 7200 operations/h
Insulation voltage
Outputs - smart-house≥ 4 kVAC (rms)
Response time1 pulse train
GENERAL SPECIFICATIONS
Output OFF delay
Upon loss of smart-house carrier20 ms Power ON delayTyp. 2 s Power OFF delay ≤ 1 s Indication for
Supply ON LED, green
Output ON4 LEDs, red
(one per motor or direction)
smart-house carrier LED, yellow
Environment
Degree of protectionIP 20 B
Pollution degree 3(IEC 60664)
Operating temperature -20° to +50°C (-4° to +122°F) Storage temperature -50° to +85°C (-58° to +185°F)
Humidity (non-condensing)20 to 80%
Mechanical resistance
Shock 15 G (11 ms)
Vibration2 G (6 to 55 Hz)
Dimensions
Material
(see Technical informations) H4-housing
Weight 300 g
SUPPLY SPECIFICATIONS
Power supply AC typesInstallations cat. III (IEC 60664)
Rated operational voltage
through term. 21 & 22 230 230 VAC ± 10% (IEC 60038) Frequency45 to 65 Hz
Drop-out tolerance≤ 40 ms
Power consumption Typ. 3.8 VA Power dissipation ≤ 9 W Transient protection volt. 230 4 kV Insulation voltage
Supply - smart-house ≥ 4 kVAC (rms) Supply - Outputs ≥ 4 kVAC (rms) smart-house - Outputs ≥ 4 kVAC (rms)
TYPE SELECTION
SupplyOrdering no.
230 VAC BH4-RO5ADC2-230
WIRING DIAGRAM
M2
MODE OF OPERATION + -
As indicated on the wiring dia- gram, there are two relays in series to control each motor. O1 is used
BAT. The default setting of the module is to switch all outputs off in case of loss of smart-house carri-
AC Supply
DC IN M1
to switch Motor 1 ON/OFF and O2 is used to control the direction of Motor 1 UP/DOWN. Corres- pondingly O3 (ON/OFF) and O4 (UP/DOWN)areused to control Motor 2. O1, O2, O3 and O4 may be coded individually by means of the code programmer BGP-COD-
er signal.
The smart-house controller pro- vides intelligent functions that ma- kes it easy for the user to control the rollerblind motors individually or several at the same time (all UP or all DOWN).
DIMENSIONS (mm)
ACCESSORIES
DIN-railFMD 411
Specifications are subject to change without notice (28.07.2009) - A product of the CARLO GAVAZZI Group

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSelected parameters Others TYPE Roller Blind module HOUSING H4 W7 - CARLO GAVAZZI - BH4-RO5ADC2-2English62 Kbytespdf1-mostradoSelected parameters Others TYPE Roller Blind module HOUSING H4 W7 - CARLO GAVAZZI - BH4-RO5ADC2-2
pdf1-Selected parameters Others TYPE Roller Blind module HOUSING H4 W7 - CARLO GAVAZZI - BH4-RO5ADC2English12 Mbytespdf1-mostradoSelected parameters Others TYPE Roller Blind module HOUSING H4 W7 - CARLO GAVAZZI - BH4-RO5ADC2-2

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review