NSO13DB24DC CARLO GAVAZZI Selected parameters FUNCTION Safety gate SAFETY CATEGORY 4 SAFETY OUTPUT 3 NO Oth..

NSO13DB24DC

CARLO GAVAZZI

Available Ship on today

Selected parameters FUNCTION Safety gate SAFETY CATEGORY 4 SAFETY OUTPUT 3 NO Others SIZE 22 mm CONNECTIONS Screw-detachable POWER SUPPLY 24 VAC/DC MOUNTING DIN-rail AUX OUTPUT 1 NC OTHERS 2 NO inputs

More details


Safety

Controls

Safety Modules

* Brand new product in its original packaging covered by the warranties and certifications provided by CARLO GAVAZZI

Quantity Price
1+$189.95
2+$183.77
3+$180.81
4+$178.95
5+$178.16
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Safety Modules
Safety Gate and Safety Magnetic Sensor
TypesNSO02D, NSO13D
Screw, fixed
Screw, detachable
• Safety Category 4, Performance Level e, according to EN 13849-1
• Safety Category 4 according to EN 954-1
• Category 0 Emergency Stop (EN 60204-1)
• Input type: 2 NO
• 2 x 6 A NO safety outputs (NSO02D)
• 3 x 6 A NO safety outputs and 1 x 6 A NC auxiliary output (NSO13D)
• Automatic / manual or monitored manual reset
• Single / double channel operations
• LED indication for outputs status and power supply ON
• Connection by fixed or detachable terminals
• For mounting on DIN-rail in accordance with DIN/EN 50
022
• 22.5 mm Euronorm housing
Product Description
Ordering KeyNSO0 2 D B24 S A
Safety gateand safety magnetic sensor modules according to EN 60204-1, EN
292-1/-2,EN418and
EN1088.
This family of safety module inSafetyCategory4,
TypeSelection
Performance Level e, includes fixed screw and detachable screw as well as automatic/manual or monitored manual restart versions.
Housing Function Auxiliary outputs Safety outputs Safety category Power supply Terminals Start/Reset type
Auxiliary outputs
Safety
outputs Terminals Start/Reset type Supply: 24 VAC/DC
2 NOScrew, fixedAutomatic / Manual N SO 0 2 D B24 S A
2 NOScrew, fixedMonitored manualN SO 0 2 D B24 S C
2 NOScrew, detachableAutomatic / Manual N SO 0 2 D B24 D A
2 NOScrew, detachableMonitored manualN SO 0 2 D B24 D C
1 NC3 NOScrew, fixedAutomatic / Manual N SO 1 3 D B24 S A
1 NC3 NOScrew, fixedMonitored manualN SO 1 3 D B24 S C
1 NC3 NOScrew, detachableAutomatic / Manual N SO 1 3 D B24 D A
1 NC3 NOScrew, detachableMonitored manualN SO 1 3 D B24 D C
TimeSpecification
Output Specification
Delay ON energisation < 150 ms Delay ON de-energisation< 30 ms Recovery time ≥ 30 ms Channel simultaneity
during outputs closingInfinite
Input operating to START
operating delay
NSO...C> 500 ms
InputSpecifications
Function2 NO, voltage free
Input current
Terminals S11-S12 max 10 mA Terminals S21-S22 max 10 mA
External contact resistance
Terminals S11-S12 max. 60Ω
Terminals S21-S22 max. 60Ω
Safety outputsCategory 4, Performance
Level e (EN 13849-1) NSO02D2 NO (13-14, 23-24) NSO13D3 NO (13-14, 23-24, 33-34)
Auxilary output
NSO13D1 NC (41-42)
Rated insulation voltage 250 VAC (rms)
Contact ratings (AgSnO2)2 µm Au
Safety outputs
Resistive loads AC1 6 A @ 230 VAC DC12 6 A @ 24 VDC
Small inductive loadsAC153 A @ 230 VAC DC13 2.5 A @ 24 VDC
Auxiliary output 6A, 24 VAC/DC
External contact fuse
protection5 A fast, 4 A slow
Mechanical life> 107 operations Electrical life> 105 operations Dielectric strength
Dielectric voltage4 kVAC (rms)
1Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network.27/09/12

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.