WM1496AV63HR2XXAX CARLO GAVAZZI Selected parameters FUNCTION Power Analyzers MOUNTING Panel POWER SUPPLY 90 .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

WM1496AV63HR2XXAX CARLO GAVAZZI Selected parameters FUNCTION Power Analyzers MOUNTING Panel POWER SUPPLY 90 ..

WM1496AV63HR2XXAX

WM1496AV63HR2XXAX

CARLO GAVAZZI

Available

Ship on today

Selected parameters FUNCTION Power Analyzers MOUNTING Panel POWER SUPPLY 90 to 260V AC/DC OUTPUT DIGITAL INPUT Relay output INPUT TYPE 3-phase AC CONNECTION CT/VT COMMUNICATION None Others RANGE 78V to 250VLL 1/5(6)AAC DISPLAY 3x3 DGT VARIABLES VLL,VLN,VLN min max,VA,VAdmd dmdmax,W,Wmax dmd,Wdmdmax,var,Hz,ASY,A,An,Amin max dmdmax,PF,PFmin,FFT DIGITAL INPUTS none PULSE 2 ALARMS 2 ANALOGUE none

More details


Energy Meters Control Analizers

Controls

Energy Management, Software and Accessories

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+279,86 €
2+273,77 €
3+272,15 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Energy Management
Power Analyzer
Type WM14 96 “Advanced version”
• Protection degree (front): IP65
• 2 digital outputs
• 16 freely configurable alarms with OR/AND logic linkable with up to 2 digital outputs
• RS422/485 serial output (MODBUS-RTU), iFIX SCADA
compatibility
Product Description
• Class 1 (kWh), Class 2 (kvarh)
• Accuracy ±0.5 F.S. (current/voltage)
• Power Analyzer
• Instantaneous variables read-out: 3 DGT
• Energies readout: 8+1 DGT
• System variables: VLL, VLN, An, Admd max, VA, VAdmd, VAdmd max, W, Wdmd, Wdmdmax, var, PF, Hz, ASY
• Single phase variables: VLL, VLN, VLN min, VLN max, A, Amin, Amax, Admd, VA, W, Wdmd, Wmax, var, PF, PFmin
• Harmonic analysis (FFT) up to the 15thharmonic (cur-
rent and voltage)
• Four quadrant power measurement
• Energy measurements: total and partial kWh and kvarh
• Hour counter (5+2 DGT)
• TRMS meas. of distorted sine waves (voltages/currents)
• Universal power supply: 90 to 260 VAC/DC, 18 to 60 VAC/DC
• Front dimensions: 96x96mm
• Voltage asymmetry, phase sequence, phase loss control
How to orderWM14-96AV5 3 H R2 S1 AX
3-phase advanced power analyzer with integrated pro- gramming key-pad. Particu- larly recommended for the measurement of the main electrical variables.
Housing for panel mounting, with RS485 communication port or pulse and/or alarm outputs.
Model Range code System
Power supply
Output 1
Output 2
Option
Type Selection
Range codes
AV5: 380/660VL-L/1/5(6)AAC VL-N: 185 V to 460 V
VL-L: 320 V to 800 V
AV6: 120/208VL-L/1/5(6)AAC VL-N: 45 V to 145 V
VL-L: 78 V to 250 V
System
3 :1, 2 or 3 phase, balanced/unbalanced load, with or without neutral
Power supply
Output 1
R2: 2-relay outputs
O2: 2-open collector outputs
Output 2
XX: None
S1: RS485/RS422 port
Options
Phase current: 0.03A to 6A
Neutral current: 0.09A to 6A
L: 18 to 60 VAC/VDC
H: 90 to 260 VAC/VDC
AX: advanced functions
Inputspecifications
Rated inputsSystem type: 3 - phase
Current3 (By shunts) Voltage4
Accuracy (display, RS485) with CT=1 and VT=1 AV5: (@25°C ±5°C, R.H. ≤60%)1150W-VA-var, FS:230VLN,
400VLL AV6: 285W-VA-var, FS:57VLN, 100VLL
Current 0.25 to 6A: ±(0.5% FS +1DGT)
0.03Ato0.25A:±(0.5%FS+7DGT) Neutral current0.25 to 6A: ±(1.5% FS +1DGT)
0.09Ato0.25A:±(1.5%FS+7DGT)
Phase-phase voltage ±(1.5% FS +1 DGT)
Phase-neutral voltage ±(0.5% FS + 1 DGT)
Active and Apparent power,0.25 to 6A: ±(1% FS +1DGT)
0.03A to 0.25A: ±(1% FS
+5DGT)
Reactive power 0.25 to 6A: ±(2% FS +1DGT)
0.03A to 0.25A: ±(2% FS
+5DGT)
Active energy Class 1 (start up current: 30mA) Reactive energyClass 2 (start up current: 30mA) Frequency±0.1Hz (48 to 62Hz) Harmonic distortion ±3% F.S. (up to 15th harmonic)
(F.S.: 100%)
Specifications are subject to change without noticeWM14 96 A DS ENG2305081

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSelected parameters FUNCTION Power Analyzers MOUNTING Panel POWER SUPPLY 90 to 2 - CARLO GAVAZZI English232 Kbytespdf1-mostradoSelected parameters FUNCTION Power Analyzers MOUNTING Panel POWER SUPPLY 90 to 2 - CARLO GAVAZZI
pdf1-Selected parameters FUNCTION Power Analyzers MOUNTING Panel POWER SUPPLY 90 to 2 - CARLO GAVAZZEnglish12 Mbytespdf1-mostradoSelected parameters FUNCTION Power Analyzers MOUNTING Panel POWER SUPPLY 90 to 2 - CARLO GAVAZZI

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review