WM14DINAV533S CARLO GAVAZZI Selected parameters FUNCTION Power Analyzers MOUNTING DIN Rail POWER SUPPLY 18 t.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

WM14DINAV533S CARLO GAVAZZI Selected parameters FUNCTION Power Analyzers MOUNTING DIN Rail POWER SUPPLY 18 t..

WM14DINAV533S

CARLO GAVAZZI

Selected parameters FUNCTION Power Analyzers MOUNTING DIN Rail POWER SUPPLY 18 to 60V AC/DC OUTPUT DIGITAL INPUT None INPUT TYPE 3-phase AC CONNECTION CT/VT COMMUNICATION RS485 Others RANGE 320V to 800VLL 1/5(6)AAC DISPLAY 3x3 DGT VARIABLES kWh, kvarh, W, Wdmd, var, VA, VAdmd, PF, V, A, An, Admd, Hz, Amax, Admd max, Wdmd max DIGITAL INPUTS none PULSE none ALARMS Virtual ANALOGUE none

Three-phase power analyzer, built-in programming keypad, basic version, DIN rail

More details


Home > CARLO GAVAZZI

* Brand new product in its original packaging covered by the warranties and certifications provided by CARLO GAVAZZI

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Energy Management
Power Analyzer
Type WM14-DIN “Basic Version”
• Class 1 (active energy)
• Class 2 (reactive energy)
• Accuracy ±0.5 F.S. (current/voltage)
• Power analyzer
• Display of instantaneous variables: 3x3 digit
• Display of energies: 8+1 digit
• System variables and phase measurements: W, Wdmd, var, VA, VAdmd, PF, V, A, An, Admd, Hz
• Amax, Admd max, Wdmdmaxindication
• Energy measurements: kWh and kvarh
• Hour counter (5+2 DGT)
• TRMS meas. of distorted sine waves (voltages/currents)
• Power supply: 24V, 48V, 115V, 230V, 50-60Hz 18 to 60VDC
• Optional dual pulse output
• Alarms (visual only) VLN, An
• Optional galvanically insulated measuring inputs
Product Description
• Protection degree (front): IP40
• Front dimensions: 107.8x90mm
• Optional RS422/485 serial port
How to orderWM14-DIN AV5 3 D PGX
3-phase power analyzer with built-in programming key- pad. Particularly recom- mended for displaying the main electrical variables. Housing for DIN-rail mount-
ing, (front) protection degree IP40, and optional RS485 serial port or dual pulse out- put. Parameters pro- grammable by means of CptBSoft.
Model Range code System
Power supply
Option
How toorder
CptBSoft
Type Selection
CptBSoft (compatible only with S or SG options): software to program the working parameters of the power analyzer and to read the energy and the instantaneous variables.
Range codes
AV5: 380/660VL-L/5(6)AAC VL-N: 185 V to 460 V VL-L: 320 V to 800 V
AV6: 120/208VL-L/5(6)AAC VL-N: 45 V to 145 V
VL-L: 78 V to 250 V Phase current: 0.03A to 6A Neutral current: 0.09 to 6A
Inputspecifications
System
3 :1-2-3-phase, balanced/unbalanced load,with or without neutral
Power supply
A: 24VAC
-15+10%, 50-60Hz
B: 48VAC
-15+10%, 50-60Hz
C: 115VAC
-15+10%, 50-60Hz
D: 230VAC
-15+10%, 50-60Hz
3:18 to 60VDC (not available in case of SG or PG options)
Options
X: None
S: RS485 port
SG:RS485+galvanic insu- lated measurig inputs
PG:Dual pulse output+ galvanically insulated measuring inputs.
Rated inputs
Current “X-S options”3 (non insulated each other) Current “SG-PG options”3 (insulated each other) Voltage4
Accuracy (display, RS485)with CT=1 and VT=1 AV5: (@25°C ±5°C, R.H. ≤60%)1150W-VA-var, FS:230VLN,
400VLL AV6: 285W-VA-var, FS:57VLN, 100VLL
Current 0.25 to 6A: ±(0.5% FS +1DGT)
0.03Ato0.25A:±(0.5%FS+7DGT) Neutral current0.25 to 6A: ±(1.5% FS +1DGT)
0.09Ato0.25A:±(0.5%FS+7DGT)
Phase-phase voltage ±(1.5% FS +1 DGT) Phase-neutral voltage ±(0.5% FS + 1 DGT)
Active and Apparent power,0.25 to 6A: ±(1% FS +1DGT)
0.03A to 0.25A: ±(1% FS+5DGT) Reactive power 0.25 to 6A: ±(2% FS +1DGT)
0.03A to 0.25A: ±(2% FS+5DGT)
Active energy “X-S option” Class 2 (start up “I”: 30mA) Reactive energy “X-S option”Class 3 (start up “I”: 30mA) Active energy “SG-PG opt.” Class 1 (start up “I”: 30mA) Reactive energy “SG-PG opt.” Class 2 (start up “I”: 30mA) Frequency±0.1Hz (48 to 62Hz)
Additional errors
Humidity≤0.3% FS, 60% to 90% RH
Temperature drift≤ 200ppm/°C
Sampling rate1400 samples/s @ 50Hz
1700 samples/s @ 60Hz
Display refresh time700ms
Display
TypeLED, 9mm
Read-out for instant. var.3x3 DGT
Read-out for energies 3+3+3 DGT (Max indication:
999 999 99.9)
Read-out for hour counter 1+3+3 DGT (Max. indication:
9 999 9.99)
Specifications are subject to change without noticeWM14 DIN B DS ENG210508 1

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.