MA1DLIFT CARLO GAVAZZI Selected parameters FUNCTION Lift levelling SAFETY OUTPUT 2 NO Others SIZE 45 mm CONN.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MA1DLIFT CARLO GAVAZZI Selected parameters FUNCTION Lift levelling SAFETY OUTPUT 2 NO Others SIZE 45 mm CONN..

MA1DLIFT

CARLO GAVAZZI

Available

Ship on today

Selected parameters FUNCTION Lift levelling SAFETY OUTPUT 2 NO Others SIZE 45 mm CONNECTIONS Screw-fixed POWER SUPPLY 24 VAC/DC MOUNTING DIN-rail AUX OUTPUT 1 static

More details


Safety

Controls

Safety Modules

* Brand new product in its original packaging covered by the warranties and certifications provided by CARLO GAVAZZI

* This article is obsolete. Please ask us for a quotation and we will check if there are units available or we will offer you an alternative product.

Related products

More info



Lift door unlocking and cabin levelling safety module
MA1DLIFT
• Certified according to the Lift Directive and
EN 81-1,/2, EN 12015 and EN 12016
• Redundant circuit
• 2 NO safety outputs
• 1 NO optocoupled Auxiliary NPN outputs
• 24 VAC/VDC power supply
• Self monitoring
• Dual channel input
• Failure diagnosis by LEDs
• Automatic or manual start
• Feedback circuit for external contactors monitoring
• Possibility to connect mechanical or magnetic switches for lift cabin position monitoring
Product Description
Ordering Key
MA1D LIFT
Lift door unlocking and lift cabin levelling safety module, certified accordingtoLiftDirective
95/16/CE and to safety circuits requirements of EN 81-1, /-2, EN
12015 and EN 12016 Standards.
The module is provided with safety outputs with forced guid- ed relay contacts, and feedback circuit.Suitedforapplications of risk category 4.
Housing Application Controlled Devices Safety Category Specific Version
Electrical Specifications
Power supply 24 VAC ± 10% 50-60Hz /
24 VDC ± 10%
Power consumption5 VA / 5 W
Input current/voltage 100 mA @ 24 VDC
Safety outputs2 NO
Auxiliary outputs1 optocoupled NO 55V 50mA
Safety output switching
voltage /current /capability 230VAC/8A/1840VA
Safety output
contact fuse protection 6 A fast or 4 A delayed
Insulation voltage2.5 KV for signal parts
4.0 KV for safety output parts: Pollution degree 2
Overvoltage category III
TimeSpecificationsEnvironmental Specifications
Delay on energisation ≤ 150 ms Delay on de-energisation≤ 25 ms Recovery time≥ 25 ms Channel simultaneity≤ 200 ms
Operating temperature0°C ... + 65°C
Storage temperature -25°C ... + 65°C
Mechanical Specifications
Protection degree terminals IP 20
Protection degree housing IP 30
Max cross section
of external conductors2.5 mm2 flexible wire
2
Housing materialABS
4 mm
rigid wire
Housing type45 mmhousing models
MountingDIN rail
Dimensions45 x 75 x 110 mm
Weight 240 g
Specifications are subjected to change without notice (20.04.07) 1

Datasheet - PDF

Title: Language: Size: Type:
pdf1-mostradoSelected parameters FUNCTION Lift levelling SAFETY OUTPUT 2 NO Others SIZE 45 mm CONNECTI - CARLO English 151 Kbytes pdf1-mostradoSelected parameters FUNCTION Lift levelling SAFETY OUTPUT 2 NO Others SIZE 45 mm CONNECTI - CARLO
pdf1-Selected parameters FUNCTION Lift levelling SAFETY OUTPUT 2 NO Others SIZE 45 mm CONNECTI - CAR English 12 Mbytes pdf1-mostradoSelected parameters FUNCTION Lift levelling SAFETY OUTPUT 2 NO Others SIZE 45 mm CONNECTI - CARLO

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review