NE14DCG CARLO GAVAZZI Selected parameters FUNCTION Extension SAFETY CATEGORY 4 SAFETY OUTPUT 4 NO Others SI.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

NE14DCG CARLO GAVAZZI Selected parameters FUNCTION Extension SAFETY CATEGORY 4 SAFETY OUTPUT 4 NO Others SI..

NE14DCG

CARLO GAVAZZI

Available

Ship on today

Selected parameters FUNCTION Extension SAFETY CATEGORY 4 SAFETY OUTPUT 4 NO Others SIZE 22 mm CONNECTIONS Screw-fixed POWER SUPPLY 24 VAC/DC MOUNTING DIN-rail AUX OUTPUT 1 NC

More details


Safety

Controls

Safety Modules

* Brand new product in its original packaging covered by the warranties and certifications provided by CARLO GAVAZZI

Quantity Price
1+$256.98
2+$246.46
3+$241.53
4+$238.49
6+$234.89
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Extension Modules
NE14DCG
• 4 NO safety outputs
• 1 NC feedback output
• 24 VAC / VDC, 110 VAC or 230 VAC power supply
• Suitable for application up to safety category 4 according to EN 954-1
• Approvals: TÜV NORD, CULUS
Product Description
Ordering Key
NE14 D 230 CG
Extension module according to EN
60204-1, EN202/1 and /2, EN 418, EN 1088 and EN 954-1. The zero delay extension modules increase the number of safety outputs. They must be used in conjunction with
Type Selection
Power supply
24 VAC/VDC
110 VAC
230 VAC
a safety module and allow to keep the same safety category. They also provide a NC feedback out- put to control the internal force guided relay integrity
References
NE14DCG NE14D110CG NE14D230CG
Housing Application Controlled Devices Safety Outputs Safety Category Power Supply
Electrical Specifications
Power supply
NE14DCG24 VAC –15/+10% 50-60 Hz
24 VDC –15/+10% NE14D110CG110 VAC –15/+10% 50-60 Hz NE14D230CG230 VAC –15+10% 50-60 Hz
Feedback output
Resistive loads AC1 5 A @ 230 V Small inductive loadsAC15 1.5 A @ 230 V
Contact fuse protection6 A fast or 4 A delayed
Insulation voltagePollution degree: 2
Power consumption4 VA /4 W
Safety outputs4 NO Feedback outputs 1 NC Contact ratings
Safety output
Resistive loads AC1 8 A @ 230 VAC Small inductive loadsAC15 3 A @ 230 VAC
DC13 4 A @ 24 VDC
Overvoltage Cat.: 3/250 V
24 VAC/DCxxx AC Supply to inputnone 4 kV 1.2/50µs Supply to output 4 kV 1.5/50µs 4 kV 1.2/50µs Input to output4 kV 1.5/50µs 4 kV 1.2/50µs
Time SpecificationsEnvironmental Specifications
Delay on energisation150 ms Delay on de-energisation< 30 ms Channel simultaneity ∞
Operating temperature-25°C ... + 55°C
Storage temperature -25°C ... + 65°C
Mechanical Specifications
Protection degree terminals IP 20
Protection degree housing IP 40
Max cross section
of external conductors2.5 mm2 flexible wire
2
Housing materialPolyamid PA6.6
2.5 mm
rigid wire
Housing type22.5 housing models
MountingDIN rail
Dimensions22.5 x 99 x 114 mm
WeightNE14DCG 170 g
NE14D110CG, NE14D230CG 240 g
Specifications are subjected to change without notice (31.08.06) 1

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.