NE14DCG CARLO GAVAZZI Selected parameters FUNCTION Extension SAFETY CATEGORY 4 SAFETY OUTPUT 4 NO Others SIZ.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

NE14DCG CARLO GAVAZZI Selected parameters FUNCTION Extension SAFETY CATEGORY 4 SAFETY OUTPUT 4 NO Others SIZ..

NE14DCG

NE14DCG

CARLO GAVAZZI

Available

Ship on today

Selected parameters FUNCTION Extension SAFETY CATEGORY 4 SAFETY OUTPUT 4 NO Others SIZE 22 mm CONNECTIONS Screw-fixed POWER SUPPLY 24 VAC/DC MOUNTING DIN-rail AUX OUTPUT 1 NC

More details


Safety

Controls

Safety Modules

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+206,96 €
2+202,07 €
3+199,65 €
4+198,99 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Extension Modules
NE14DCG
• 4 NO safety outputs
• 1 NC feedback output
• 24 VAC / VDC, 110 VAC or 230 VAC power supply
• Suitable for application up to safety category 4 according to EN 954-1
• Approvals: TÜV NORD, CULUS
Product Description
Ordering Key
NE14 D 230 CG
Extension module according to EN
60204-1, EN202/1 and /2, EN 418, EN 1088 and EN 954-1. The zero delay extension modules increase the number of safety outputs. They must be used in conjunction with
Type Selection
Power supply
24 VAC/VDC
110 VAC
230 VAC
a safety module and allow to keep the same safety category. They also provide a NC feedback out- put to control the internal force guided relay integrity
References
NE14DCG NE14D110CG NE14D230CG
Housing Application Controlled Devices Safety Outputs Safety Category Power Supply
Electrical Specifications
Power supply
NE14DCG24 VAC –15/+10% 50-60 Hz
24 VDC –15/+10% NE14D110CG110 VAC –15/+10% 50-60 Hz NE14D230CG230 VAC –15+10% 50-60 Hz
Feedback output
Resistive loads AC1 5 A @ 230 V Small inductive loadsAC15 1.5 A @ 230 V
Contact fuse protection6 A fast or 4 A delayed
Insulation voltagePollution degree: 2
Power consumption4 VA /4 W
Safety outputs4 NO Feedback outputs 1 NC Contact ratings
Safety output
Resistive loads AC1 8 A @ 230 VAC Small inductive loadsAC15 3 A @ 230 VAC
DC13 4 A @ 24 VDC
Overvoltage Cat.: 3/250 V
24 VAC/DCxxx AC Supply to inputnone 4 kV 1.2/50µs Supply to output 4 kV 1.5/50µs 4 kV 1.2/50µs Input to output4 kV 1.5/50µs 4 kV 1.2/50µs
Time SpecificationsEnvironmental Specifications
Delay on energisation150 ms Delay on de-energisation< 30 ms Channel simultaneity ∞
Operating temperature-25°C ... + 55°C
Storage temperature -25°C ... + 65°C
Mechanical Specifications
Protection degree terminals IP 20
Protection degree housing IP 40
Max cross section
of external conductors2.5 mm2 flexible wire
2
Housing materialPolyamid PA6.6
2.5 mm
rigid wire
Housing type22.5 housing models
MountingDIN rail
Dimensions22.5 x 99 x 114 mm
WeightNE14DCG 170 g
NE14D110CG, NE14D230CG 240 g
Specifications are subjected to change without notice (31.08.06) 1

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSelected parameters FUNCTION Extension SAFETY CATEGORY 4 SAFETY OUTPUT 4 NO Others SIZE 2 - CARLOEnglish156 Kbytespdf1-mostradoSelected parameters FUNCTION Extension SAFETY CATEGORY 4 SAFETY OUTPUT 4 NO Others SIZE 2 - CARLO
pdf1-Selected parameters FUNCTION Extension SAFETY CATEGORY 4 SAFETY OUTPUT 4 NO Others SIZE 2 - CAREnglish12 Mbytespdf1-mostradoSelected parameters FUNCTION Extension SAFETY CATEGORY 4 SAFETY OUTPUT 4 NO Others SIZE 2 - CARLO

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review