EM11DINAV81XR1X CARLO GAVAZZI Selected parameters FUNCTION Energy analyzer MOUNTING DIN Rail POWER SUPPLY S.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

EM11DINAV81XR1X CARLO GAVAZZI Selected parameters FUNCTION Energy analyzer MOUNTING DIN Rail POWER SUPPLY S..

EM11DINAV81XR1X

CARLO GAVAZZI

Selected parameters FUNCTION Energy analyzer MOUNTING DIN Rail POWER SUPPLY Self power supply OUTPUT DIGITAL INPUT Relay output INPUT TYPE 1-phase AC CONNECTION Direct COMMUNICATION None Others RANGE 230VLN AC 5(32)A DISPLAY 5+1 DGT VARIABLES kWh, kvarh, V, A, W, Wdmd, Wdmd max, var, PF, Hz DIGITAL INPUTS none PULSE none ALARMS 1 ANALOGUE none

More details


Energy Meters Control Analizers

Controls

Energy Management, Software and Accessories

* Brand new product in its original packaging covered by the warranties and certifications provided by CARLO GAVAZZI

* This article is obsolete. Please ask us for a quotation and we will check if there are units available or we will offer you an alternative product.

Related products

More info



Energy Management Energy Analyzer Type EM11DIN
• Other versions available (not certified, option X):
see “how to order” on the next page
Product Description
• Class 1 (kWh) according to EN62053-21
• Class B (kWh) according to EN50470-3
• Class 2 (kvarh) according to EN62053-23
• Accuracy ±0.5 RDG (current/voltage)
• Energy analyzer
• Instantaneous variables readout: 4 DGT
• Energies readout: 6 DGT
• Instantaneous variables: V, A, W, Wdmd, Wdmd max, var,
PF, Hz
• Single phase variables: VLL, VLN, A, VA, W, var, PF
• Energy measurements: total kWh and kvarh
• TRMS measurements of distorted sine waves
(voltages/currents)
• Self power supply
• Dimensions: 1-DIN module
• Protection degree (front): IP40
• 1 pulse output on request
• 1 alarm output on request
• Certified according to MID Directive (option PF only):
see “how to order” below
One-phase energy analyzer with built-in configuration push buttonand LCD data displaying particularly indicated for active and
reactive energy metering and for cost allocation. Housing for DIN-rail mounting, IP40 (front) protection degree.Direct
connection up to 32A. Moreover the meter can be provided with either pulse outputproportionaltothe
active energy being measured or alarm control on the available instantaneous variables.
MID
Certified according to MID Directive, Annex "B" + Annex "D" for legal metrolo- gyrelevanttoactiveelectricalenergy
How to orderEM11 DIN AV8 1 X O1 PF
Model
Range code
meters (see Annex MI-003 of MID). Can be used for fis-
cal (legal) metrology.
System
Power supply
Output
Option
Type Selection
Range code
AV8: 230VLN AC - 5(32)A (direct connection)
System
1:1-phase
Output
O1: Pulse type (open collector output)
Power supply
X: Self power supply (from 48 to 62Hz). The instrument works on the range from -20% to +20% of the measuring input nominal voltage.
Option
PF: Certified according to MID Directive, Annex "B" + Annex "D" for legal metrol- ogy relevant to active electrical energy meters (see Annex MI-003 of MID). Can be used for fiscal (legal) metrology.
AV81
X O1PF
NOTE: please check the availability of the needed code on the verification path diagram on left before order.
Specifications are subject to change without notice EM11DIN DS ENG 3010121

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.