Product successfully added to your shopping cart
1SDA068109R1
ABB
1
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Molded Case Circuit Breakers ≤ 250 A Xtmax
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 56.3 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2351 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108469A1857 |
| 9AKK108468A1892 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | dbf6e219-bb32-4109-8dcb-1f136b98a70e Italy (IT) |
| Simplified SCIP | b4da11e0-0581-4733-b8d9-84d32d6c20af Hungary (HU) |
| 4a4c0d2f-9b83-4c13-a2bf-bc1a0fe6ee67 France (FR) | |
| 9320627a-aec8-4cb1-a348-e97b2921eeb6 Belgium (BE) | |
| a450b123-075e-4235-bcc1-49f7c37e92b8 Denmark (DK) | |
| bfa512e6-ee49-4087-9e69-7290a2cac55a Spain (ES) | |
| 5b27f7fb-bb60-4b73-8dbb-79d069cbdcb2 Sweden (SE) | |
| 7b6be281-7a8a-4006-bc37-304655fd9a95 Germany (DE) | |
| 29c222e2-5909-4c53-b078-c62d036e462b Croatia (HR) | |
| f4a7fa59-ef4d-47e8-8248-f09419868f81 Germany (DE) | |
| 541f3c20-c8f5-42fe-b06c-7253c3bcf0a1 Czech Republic (CZ) | |
| 890257fb-b119-44ce-9eb0-3081cbe853a5 Germany (DE) | |
| 59f8a6c4-d2a5-43af-a55e-29e91e76f2a4 Sweden (SE) | |
| 0ae02483-72d9-4bab-8e2f-48df41db86ca Poland (PL) | |
| d8fd86b0-4c67-412c-aae0-1cc12e693426 Finland (FI) | |
| c114772d-98eb-41fc-ac0b-95438470098b Hungary (HU) | |
| 23721aa3-c3ca-4fba-a129-a65a08e7b2f8 Greece (GR) | |
| 41a24f1a-9a37-42bf-8a60-b0a50bffeef5 Belgium (BE) | |
| d8a13ae4-600c-4e72-af8f-fdd92e06395f Estonia (EE) | |
| 39891621-9115-4522-ad2d-1fd8655b16b5 France (FR) | |
| 4d8211e0-2822-4b5f-a8c6-ee46c40ae882 Portugal (PT) | |
| 3101ae52-a96d-45ac-b024-c2c454335526 Germany (DE) | |
| 4ca8e776-fb4d-4e01-8736-1bfa16ce6c1d Germany (DE) | |
| beb7934e-2761-406f-808e-9eb38be1f24b Bulgaria (BG) | |
| 9af53ab3-25e6-43a2-b496-3ff6033b63d6 Poland (PL) | |
| 172587d0-fcd7-49a6-a6a3-713dc5e19738 Poland (PL) | |
| 2bcfc708-1792-4385-885c-3f8b795189d6 Norway (NO) | |
| d6b6a253-4be3-49f3-a468-4284026afe84 Netherlands (NL) | |
| Ordering | |
| Order Code US and Canada | XT4NE4200BFF000XXX |
| EAN | 8015644014001 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 140 mm |
| Product Net Height | 160 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 3.5 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 145 mm |
| Package Level 1 Height | 210 mm |
| Package Level 1 Depth / Length | 168 mm |
| Package Level 1 Gross Weight | 3.5 kg |
| Package Level 1 EAN | 8015644014001 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Connecting Capacity Main Circuit | Busbar 85..200 mm² |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 4 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 11.88 W |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Rated Current (In) | 200 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 1000…2000 A |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| 750 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (240 V AC) 65 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 20 kA | |
| (690 V AC) 10 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 3 Poles in Series 36 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (240 V AC) 65 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 20 kA | |
| (690 V AC) 10 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 3 Poles in Series 36 kA | |
| Rated Uninterrupted Current (Iu) | 250 A |
| Recommended Screw Driver | Main Circuit M8 |
| Release | TMA |
| Release Type | TM |
| Setting Range | 140...200 A |
| Short-Circuit Performance Level | N |
| Standards | IEC60947-2 |
| Sub-type | XT4 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 8 N·m |
| Version | F |
| CAD Dimensional Drawing | 1SDH001295R0677 |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5529 |
| GL Certificate | 1SDL000163R0095 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000722R0100 |
| Mechanical Drawings | 1SDH000722R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000722R0001 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG MOLDED CASE ISOMAX-TMAX 2024 EN.pdf | 71 Mbytes |
|
| XT4N 250 TMA 200-2000 4p F F InN100% - ABB - XT4N250 - 1SDA068109R1 | 90 Kbytes |
![]() |
| XT4N250 1SDA068109R1 ABB XT4N 250 TMA 200-2000 4p F F InN 100% | 76 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.