ANUNCIAR
1SDA067802R1 ABB XT2S 160 Ekip LS/I In 63A 3p F F View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SDA067802R1 ABB XT2S 160 Ekip LS/I In 63A 3p F F

1SDA067802R1

ABB

XT2S 160 Ekip LS/I In=63A 3p F F

XT2S160 Ekip LS/I R63 3P F F

More details


Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection

Molded case "Isomax-Tmax" > XT2

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $410.61
Unit price: $410.61
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ABB EcoSolutions
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions9AKK108468A2349
Environmental Product Declaration - EPD9AKK108469A1855
9AKK108468A1897
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 55.70 %
Material Compliance
REACH Declaration9AKK108466A1425
RoHS Declaration9AKK108466A1424
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
Toxic Substances Control Act - TSCA9AKK108467A8326
SCIP352cf3d0-825c-4c72-91a2-181930278538 Italy
Simplified SCIP59f85ef3-ecc4-4bbf-8ea6-e5fa59b52623 Germany
6c7a6eba-513b-4849-a07a-87191ccf5193 Poland
42b85f0b-d746-47c4-9c28-c4c62c58b1d3 Norway
df863d7e-ef5e-4f1b-95ea-f0e23916b20a Finland
05b188fa-ce55-42f2-9724-692cf074132b Netherlands
1b836845-bb2b-49fe-b80c-50dd58698c21 Germany
521c1234-63a1-4885-85d0-9c0c2436ff77 Netherlands
b3df6053-bb30-4bbf-9239-a0ba894bd40c Netherlands
141b2761-9488-40f4-9691-afed569b7ae1 Estonia
f5b35713-9bd5-4cca-954f-8cd2403fb720 Greece
5da2ca44-8af2-4a4d-b7ca-0ad9507080ee Portugal
274e6100-2a17-45c7-8d66-714645efd1b5 Denmark
1f35aaa8-b202-47cb-be76-3958c2cfc72e Germany
af53d568-0327-4ebe-8d47-f3faa5ff5975 Croatia
f3a08021-3c82-4496-9993-ba2cdea0929a Czech Republic
71d55f57-b1cb-408f-9652-254a1ce45d23 Poland
5b58fb1e-519c-41da-b244-462b5eebb486 Sweden
bfa9a857-3442-4709-9c51-32249c49462c Germany
9b6d329d-db51-4453-8eed-ac96b2ed6b12 France
a9542ea2-6652-49ec-8cbb-442828eeaa49 Netherlands
ffbbac81-7c04-4df7-8084-a59f85ff8d30 Spain
466ca681-b47d-4681-b5c4-f6ae7ea5ab13 Germany
10f44d46-6150-49c7-b5fe-192b60b37903 Netherlands
2061c8fb-9712-4d81-89ab-f540e27424ff Bulgaria
5ba8b9f4-f60a-45b4-a5b1-2e152d657e13 Sweden
d6055301-5bec-46b5-b1aa-14da395de42a Poland
4ade0e09-ee08-4e45-b030-0384137534b1 France
Environmental
Environmental Information9AKK108467A6707
Ordering
Order Code US and CanadaXT2SE3063EFF000XXX
E-Number (Finland)3640583
E-Number (Norway)4309654
E-Number (Sweden)3182028
EAN8015644016982
Minimum Order Quantity1 piece
Customs Tariff Number85362090
Dimensions
Product Net Width90 mm
Product Net Height130 mm
Product Net Depth / Length82.5 mm
Product Net Weight1.4 kg
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width130 mm
Package Level 1 Height208 mm
Package Level 1 Depth / Length145 mm
Package Level 1 Gross Weight1.696 kg
Package Level 1 EAN8015644016982
Additional Information
Circuit Breaker Type to be AssociatedPower Distribution
Product Main TypeSACE Tmax XT
Product NameMoulded Case Circuit Breaker
Product TypeAutomatic Circuit Breaker
VersionF
CAD Dimensional Drawing1SDH002230A1001
Technical
Connecting Capacity Main CircuitBusbar 32.5..100 mm²
Current TypeAC
Electrical Durability120 cycles per hour
8000 cycle
Mechanical Durability240 cycles per hour
25000 cycle
Number of Poles3P
Opening TimeCB with SOR 30 ms
CB with UVR 30 ms
Order Multiple1 piece
Power Lossat Rated Operating Conditions per Pole 1.7 W
Rated Current (In)63 A
Rated Frequency (f)50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)8 kV
Rated Insulation Voltage (Ui)1000 V
Rated Operational Voltage690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
Rated Uninterrupted Current (Iu)160 A
Rated Voltage (Ur)690 V
Recommended Screw DriverMain Circuit M6
ReleaseEkip Dip LS/I
Release TypeEL
Short-Circuit Performance LevelS
StandardsIEC60947-2
Sub-typeXT2
Terminal Connection TypeFront
Terminal TypeBolt
Tightening Torque6 N·m
Certificates and Declarations
ATEX CertificateNo certification needed
Data Sheet, Technical InformationSDC210100D0206
1SDC210099D0206
Declaration of Conformity - CE9AKK106713A5901
GL Certificate1SDL000163R0093
LR Certificate1SDL000163R0100
UL CertificateNo certification needed
VDE CertificateNo certification needed
Dimension Diagram1SDH000721R0100
Mechanical Drawings1SDH000721R0100
Wiring Diagram1SDM000068R0001
Instructions and Manuals1SDH000721R0001
External Classifications and Standards
ETIM 9EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification CodeQ
UNSPSC39120000
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
eClassV11.1 : 27370409

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.