Product successfully added to your shopping cart
1SDA067052R1
ABB
1
XT2N 160 MA 80 Im=480...1120 3p F F
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax" > XT2
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 55.70 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2348 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108469A1856 |
| 9AKK108468A1891 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 3a67bffc-07bb-4eb4-bdbc-0799f2bdadf6 Italy (IT) |
| Simplified SCIP | a1760667-126c-4554-9aef-e50f65670781 Spain (ES) |
| ce7eceb7-cda1-4218-af7c-030ee2fcf723 Belgium (BE) | |
| 2ace57a6-4ee7-4bd8-a495-8a16de665e1d Denmark (DK) | |
| 75f540e5-0ef9-49c3-8c2d-a3e227b12e30 Sweden (SE) | |
| c8fd42dd-43e3-4807-a0f9-cd8b75fb4064 Germany (DE) | |
| 04be9869-70b6-4b93-bb77-1915b820b56a Germany (DE) | |
| 023064c6-e107-455e-b8b8-2c0cd2605b09 Croatia (HR) | |
| 357cecf5-7937-4576-af93-ee897368a1d6 Czech Republic (CZ) | |
| 8f639353-c133-47eb-a944-9788dc5453a3 Germany (DE) | |
| a7f2c05b-faeb-44e8-940f-92973647662d Hungary (HU) | |
| 3a8d4787-80a2-4b1a-ab96-fdf5cfdbab0d France (FR) | |
| d04f4a1f-2c09-430b-b02f-fcb825517799 Portugal (PT) | |
| db7e42fe-09a2-4662-8b8e-8104f0d96588 Germany (DE) | |
| 67ee3326-59c9-43be-85e6-2ee233d1ca9a Poland (PL) | |
| 137c0a53-88b3-4c45-aac1-69fb9cf74781 Finland (FI) | |
| f368cc1a-3d41-49b1-8492-7159709e7f68 Sweden (SE) | |
| aa5ad7c5-2167-4dbf-8aef-8eea2c22e376 Netherlands (NL) | |
| e545046f-0509-4f47-bc1a-31360c08a218 Norway (NO) | |
| e2e7e2eb-ca7f-4a98-b02a-7e1efca92685 Bulgaria (BG) | |
| 8c201c66-0673-453d-9f98-85be04ff8e09 Poland (PL) | |
| 37e54526-66d6-4f3d-87c8-a6a134d6e09f Poland (PL) | |
| 712f5527-c654-46ca-b4af-187cd500a9aa Estonia (EE) | |
| 49285c8a-e017-4d59-886e-1af19356b903 Belgium (BE) | |
| 0100cdba-ab7b-458b-9c4a-f0d483db5e88 Hungary (HU) | |
| 7845c99b-3706-4660-adab-005413c4ae3d Greece (GR) | |
| c020ab16-7d4a-4f5f-b4bf-b2c7d9de3ea4 Germany (DE) | |
| c023d139-00ff-4372-97e2-aaf7af30b03f France (FR) | |
| Ordering | |
| Order Code US and Canada | XT2NE3080MFF000XXX |
| EAN | 8015644009588 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 90 mm |
| Product Net Height | 130 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 1.4 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 130 mm |
| Package Level 1 Height | 208 mm |
| Package Level 1 Depth / Length | 145 mm |
| Package Level 1 Gross Weight | 1.672 kg |
| Package Level 1 EAN | 8015644009588 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Motor Protection |
| Connecting Capacity Main Circuit | Busbar 32.5..100 mm² |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 5.8 W |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Rated Current (In) | 80 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 480…1120 A |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (240 V AC) 65 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 20 kA | |
| (690 V AC) 10 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 3 Poles in Series 36 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (240 V AC) 65 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 20 kA | |
| (690 V AC) 10 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 3 Poles in Series 36 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Recommended Screw Driver | Main Circuit M6 |
| Release | MA |
| Release Type | M |
| Short-Circuit Performance Level | N |
| Standards | IEC60947-2 |
| Sub-type | XT2 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 6 N·m |
| Version | F |
| CAD Dimensional Drawing | 1SDH002230A1001 |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5901 |
| GL Certificate | 1SDL000163R0093 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000721R0100 |
| Mechanical Drawings | 1SDH000721R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000721R0001 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG ABB TMAX XT EN.pdf | 70 Mbytes |
|
| XT2N 160 MA 80 Im480...1120 3p F F - ABB - XT2N160 - 1SDA067052R1 | 90 Kbytes |
![]() |
| XT2N160 1SDA067052R1 ABB XT2N 160 MA 80 Im 480...1120 3p F F | 75 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.