Product successfully added to your shopping cart
1SDA066816R1
ABB
1
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax" > XT1
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 55.9 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2347 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108468A1890 |
| 9AKK108468A7793 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 7e73f8c2-9fcf-46fd-8ce8-8ff3065446c7 Italy (IT) |
| Simplified SCIP | 44cb4be4-a1b4-471c-80e4-5307577945cb Germany (DE) |
| 2b4cd088-0d46-4c30-bb6a-fb441b7fb7fb Poland (PL) | |
| b7062f07-5e00-42af-9950-e858adf3f3bd Norway (NO) | |
| 3f87f6c9-8b2b-4ba3-84e7-e4bf7c4dbc7c Finland (FI) | |
| b0f1fc93-a34d-458d-8e5e-7e6c7fda2025 Netherlands (NL) | |
| 0994645c-6924-49ce-aa7d-e31f5e03f896 Germany (DE) | |
| 11a258b4-39ac-46b4-8a4c-aeed35ebf9da Denmark (DK) | |
| 7998dd24-22f6-40bf-90a9-f95105e027b1 Germany (DE) | |
| 1380dbaa-9f5b-4c5a-a7f2-568dc4c78999 Croatia (HR) | |
| 5ffe1b0a-3c9a-42c4-861e-3d907b4f9fa3 Czech Republic (CZ) | |
| 6abaabeb-16c8-4cb6-aef2-7390cbe2b1da Poland (PL) | |
| 32be922d-f98f-47fe-9186-edcf13f4f64b Netherlands (NL) | |
| 54b32461-e46b-4996-bcf2-3f2b76dbdd71 Netherlands (NL) | |
| 43eb203d-6065-412f-b732-744eae5e5eb0 Estonia (EE) | |
| c4908d83-b7ef-4b8d-8997-e74109d80de6 Greece (GR) | |
| 320d11f0-a17d-4e87-a794-375d391e75f4 Portugal (PT) | |
| e6eb8d27-f481-4de3-a533-d3fe70af7f6a Bulgaria (BG) | |
| 34915fc1-7263-488f-b83f-da09bdd995be Sweden (SE) | |
| a540bb0a-5c6d-479d-8984-36b5f089d8a7 Poland (PL) | |
| c3e3417c-d555-4879-9f50-f327aba9cc45 France (FR) | |
| cf23ebf3-cbe3-4128-a848-761e96a2adb6 Sweden (SE) | |
| 89e58f18-2822-40de-b715-47eeb3764a40 Germany (DE) | |
| 4f114a61-8884-4a65-a44a-0c453d2e1ada Germany (DE) | |
| 8e0863a3-ad22-4ce7-983c-ea3d4580aac7 France (FR) | |
| 61686ad8-6b0e-43f3-b96a-9777eabf3f98 Netherlands (NL) | |
| 1f1f32e9-0f0b-4294-84ff-23fee2cdc5ab Spain (ES) | |
| 72846ad8-efea-488f-9610-a0ce79670d85 Netherlands (NL) | |
| Ordering | |
| Order Code US and Canada | XT1BE4063AFF000XXX |
| E-Number (Finland) | 3638196 |
| EAN | 8015644007232 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 101.6 mm |
| Product Net Height | 130 mm |
| Product Net Depth / Length | 70 mm |
| Product Net Weight | 1.4 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 128 mm |
| Package Level 1 Height | 135 mm |
| Package Level 1 Depth / Length | 143 mm |
| Package Level 1 Gross Weight | 1.43 kg |
| Package Level 1 EAN | 8015644007232 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Connecting Capacity Main Circuit | Busbar 45.5 ... 80 mm² |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 4 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 4.3 W |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Rated Current (In) | 63 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 630 A |
| Rated Insulation Voltage (Ui) | 800 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 25 kA |
| (230 V AC) 25 kA | |
| (240 V AC) 25 kA | |
| (380 V AC) 18 kA | |
| (415 V AC) 18 kA | |
| (440 V AC) 11.25 kA | |
| (500 V AC) 8 kA | |
| (525 V AC) 6 kA | |
| (690 V AC) 3 kA | |
| (250 V DC) 2 Poles in Series 18 kA | |
| (500 V DC) 3 Poles in Series 18 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 25 kA |
| (230 V AC) 25 kA | |
| (240 V AC) 25 kA | |
| (380 V AC) 18 kA | |
| (415 V AC) 18 kA | |
| (440 V AC) 15 kA | |
| (500 V AC) 8 kA | |
| (525 V AC) 6 kA | |
| (690 V AC) 3 kA | |
| (250 V DC) 2 Poles in Series 18 kA | |
| (500 V DC) 3 Poles in Series 18 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Recommended Screw Driver | Main Circuit M6 |
| Release | TMD |
| Release Type | TM |
| Setting Range | 44.1...63 A |
| Short-Circuit Performance Level | B |
| Standards | IEC60947-2 |
| Sub-type | XT1 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 6 N·m |
| Version | F |
| CAD Dimensional Drawing | 1SDH001295R0080 |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5532 |
| GL Certificate | 1SDL000163R0103 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000719R0100 |
| Mechanical Drawings | 1SDH000719R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000719R0001 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG ABB TMAX XT EN.pdf | 70 Mbytes |
|
| XT1B 160 TMD 63-630 4p F F - ABB - XT1B160 - 1SDA066816R1 | 89 Kbytes |
![]() |
| XT1B160 1SDA066816R1 ABB XT1B 160 TMD 63-630 4p F F | 76 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.