ANUNCIAR
1SAZ421201R1005 ABB TA200DU-175 Thermal Overload Relay View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SAZ421201R1005 ABB TA200DU-175 Thermal Overload Relay

1SAZ421201R1005

ABB

TA200DU-175 Thermal Overload Relay

TA200DU175 THERMAL RELAY 130-175A

TA200DU-175 Thermal Overload Relay 130 ... 175 A

More details


Low-voltage industrial components > Thermal overload relay

Contactors and overload relays > Thermal Relays

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $241.11
Unit price: $241.11
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information1SBC100214C0202
Instructions and Manuals2CDC106028M6802
Instructions and Manuals (Part 2)1SAC200017M0002
Time-Current Characteristic Curve1SAZ400502F0005
CAD Dimensional Drawing2CDC001079B0201
Dimension Diagram1SAZ400401F0001
Dimensions
Product Net Width104 mm
Product Net Height151 mm
Product Net Depth / Length126 mm
Product Net Weight0.77 kg
Technical
Setting Range130 ... 175 A
Rated Operational VoltageAuxiliary Circuit 440 V DC
Auxiliary Circuit 500 V AC
Main Circuit 690 V AC
Main Circuit 440 V DC
Rated Operational Current (Ie)175 A
Rated Frequency (f)Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit DC
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Main Circuit 6 kV
Rated Insulation Voltage (Ui)690 V
Number of Poles3P
Number of Auxiliary Contacts NC1
Number of Auxiliary Contacts NO1
Number of Protected Poles3
Conventional Free-air Thermal Current (Ith)Auxiliary Circuit NC 5 A
Auxiliary Circuit NO 5 A
Rated Operational Current AC-15 (Ie)(120 V) NC 3 A
(120 V) NO 1.5 A
(240 V) NC 3 A
(240 V) NO 1.2 A
(400 V) NC 0.75 A
(400 V) NO 0.37 A
(440 V) NC 0.75 A
(440 V) NO 0.37 A
(500 V) NC 0.3 A
(500 V) NO 0.25 A
Rated Operational Current DC-13 (Ie)(125 V) NC 0.25 A
(125 V) NO 0.25 A
(24 V) NC 1.25 A
(24 V) NO 1.25 A
(250 V) NC 0.12 A
(250 V) NO 0.04 A
(60 V) NC 0.25 A
(60 V) NO 0.25 A
Degree of ProtectionHousing IP20
Main Circuit Terminals IP00
Pollution Degree3
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 0.75 ... 4 mm²
Connecting Capacity Main CircuitHole Diameter > 10 mm²
Rigid or Flexible with Cable Lug 1x 25 ... 120 mm²
Tightening TorqueAuxiliary Circuit 1 ... 1.3 N·m
Main Circuit 25 N·m
Wire Stripping LengthAuxiliary Circuit 9 mm
Recommended Screw DriverAuxiliary Circuit Pozidriv 1
Main Circuit Open Bars
Mounting Position1 ... 6
Power Lossat Rated Operating Conditions per Pole 3.8 ... 6.9 W
Suitable ForA145
A185
AF145
AF185
AF190
AF205
StandardsIEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-4-1
Technical UL/CSA
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Contact Rating UL/CSA(NC:) B600
(NO:) C600
Connecting Capacity Main Circuit UL/CSAFlexible 1x 4-0000 AWG
Stranded 1x 4-0000 AWG
Connecting Capacity Auxiliary Circuit UL/CSAFlexible 1/2x 18-14 AWG
Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSAAuxiliary Circuit 12 in·lb
Main Circuit 220 in·lb
Environmental
Ambient Air TemperatureOperation -25 ... +55 °C
Operation Compensated -25 ... +55 °C
Storage -40 ... +70 °C
Ambient Air Temperature CompensationYes
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 12g
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006525
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill
End Of Life Disassembling Instructions1SAC200335H0001
Environmental Information1SAC200056H0009
Environmental Product Declaration - EPD1SAC200275H0001
Certificates and Declarations
ABS Certificate1SAA941000-0102
BV Certificate1SAA941000-0201
CB Certificate1SAA941004-2003
CCC Certificate2024010304659820
CQC CertificateCQC2016010309922936
Declaration of Conformity - CCC2020980304001321
Declaration of Conformity - CE1SAD101100-3509
Declaration of Conformity - UKCA1SAD201100-3509
DNV Certificate1SAA941000-0304
DNV GL Certificate1SAA941000-0304
EAC Certificate1SAA941002-2702
GL Certificate1SAA941000-0304
LR Certificate1SAA941000-0504
RMRS Certificate1SAA941000-0704
UL CertificateE48139-19910930
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width165 mm
Package Level 1 Height133 mm
Package Level 1 Depth / Length151 mm
Package Level 1 Gross Weight1.02 kg
Package Level 1 EAN4013614286056
Package Level 2 Units4 piece
Package Level 2 Width280 mm
Package Level 2 Height210 mm
Package Level 2 Depth / Length395 mm
Package Level 2 Gross Weight8.786 kg
Package Level 2 EAN4013614494277
External Classifications and Standards
Object Classification CodeF
ETIM 9EC000106 - Thermal overload relay
ETIM 10EC000106 - Thermal overload relay
eClassV11.0 : 27371501
UNSPSC39122330
IDEA Granular Category Code (IGCC)5366 >> Thermal overload relay
E-Number (Finland)3709361
E-Number (Sweden)3228708

ETIM for 1SAZ421201R1005 Low-voltage industrial controls and switchgear (EC000106)
Feature Name Feature Value
Adjustable current range (EF008211) 130 A
Max. rated operation voltage Ue (EF007357) 690 V
Mounting method (EF000003) Direct attachment
Type of electrical connection of main circuit (EF006819) Screw connection
Number of auxiliary contacts as normally closed contact (EF001377) 1
Number of auxiliary contacts as normally open contact (EF001376) 1
Number of auxiliary contacts as change-over contact (EF003531) 1
Release class (EF006668) CLASS 10 A
Reset function input (EF011940) No
Reset function automatic (EF011941) Yes
Reset function push-button (EF011942) Yes

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.