Product successfully added to your shopping cart
1SDA054389R1
ABB
1
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax" > T5
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 143f2a67-24a7-4d43-8df4-f06a436a1906 China |
| Simplified SCIP | ed8dcb4d-90e8-4de2-9afa-848751959f40 Sweden |
| cd941134-71ac-4987-b5d1-0755bd4bdd02 Finland | |
| efe64e49-72ed-4985-a754-9962d41a8dcf Norway | |
| 95596027-7a2d-442d-8f74-acbbc4a0db18 Portugal | |
| 99379f35-04c6-4e04-8d9a-e8ebf3c4486b Belgium | |
| 675c9b40-2ce3-4014-8f7a-7bdd0396616c Poland | |
| d49aef05-61d1-47f2-82cf-4f265f4bf2d1 Spain | |
| 3015a8be-e112-431a-9f98-4a2d9db9f9ff Bulgaria | |
| c8dc6463-fe0b-43dc-b883-187ac7ec321c Greece | |
| 6bd3ea1a-1a73-4449-bcf4-3269ff0b873d Denmark | |
| 6deca1ad-a809-4c09-b2f5-39fd96815fb0 Germany | |
| 4d5eda3f-5413-4abc-88f1-e5818ee27256 Czech Republic | |
| 9c9e183f-2e51-42a6-be13-559acf1aa41c Germany | |
| b5807969-0683-45fb-bf95-9a942a04ee45 Poland | |
| d3b13f65-b042-4c7a-9fcc-311a727ff41f Estonia | |
| e45d2674-19ce-4c53-85d8-3f1e0a81d371 Hungary | |
| fb643b5a-8a0c-49fa-a2ab-9d5e719824a2 Netherlands | |
| 7414bc7a-5631-4703-a07d-c8f3b3655c43 France | |
| 57b594c3-749c-4b50-a3f0-5239bd56c1b1 Croatia | |
| 16d29b21-f8a8-4363-bb31-a6595ac8c56a Germany | |
| 09e284cd-1ebc-422b-9868-3322b9ccfdc1 Poland | |
| 6d130421-323f-4052-84ee-0e903d525a30 France | |
| 8484e08f-0aaa-4160-8557-285ca2290630 Belgium | |
| ec0b2a37-c76b-4b10-b0b3-8335cdbccb8d Germany | |
| 0d82b029-d67b-45e6-a262-6052705d12db Germany | |
| 6eb39fbb-d37a-490f-a848-e874a38bb2f5 Sweden | |
| 7ea93ab8-b1c9-4f63-a966-a90f06ddca28 Hungary | |
| Environmental | |
| Environmental Information | 9AKK10103A1056 |
| 9AKK108467A6707 | |
| Ordering | |
| E-Number (Finland) | 3655349 |
| EAN | 8015644554873 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 186 mm |
| Product Net Height | 205 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 6.2 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 248 mm |
| Package Level 1 Height | 240 mm |
| Package Level 1 Depth / Length | 285 mm |
| Package Level 1 Gross Weight | 6.2 kg |
| Package Level 1 EAN | 8015644554873 |
| Additional Information | |
| Product Main Type | SACE Tmax T |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Suitable For | T5 |
| Suitable for Product Class | Moulded Case Circuit Breakers |
| Version | F |
| Technical | |
| Electrical Durability | 7000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 4P |
| Power Loss | at Rated Operating Conditions per Pole 16.5 W |
| Rated Current (In) | 400 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 200 kA |
| (230 V AC) 200 kA | |
| (380 V AC) 200 kA | |
| (400 V AC) 200 kA | |
| (415 V AC) 200 kA | |
| (440 V AC) 180 kA | |
| (500 V AC) 150 kA | |
| (690 V AC) 80 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 5 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 200 kA |
| (230 V AC) 200 kA | |
| (380 V AC) 200 kA | |
| (400 V AC) 200 kA | |
| (415 V AC) 200 kA | |
| (440 V AC) 180 kA | |
| (500 V AC) 150 kA | |
| (690 V AC) 80 kA | |
| Rated Uninterrupted Current (Iu) | 400 A |
| Release | PR221DS-LS/I |
| Release Type | EL |
| Short-Circuit Performance Level | V |
| Standards | IEC |
| Sub-type | T5 |
| Terminal Connection Type | Fixed Circuit-Breakers |
| Front | |
| Test Voltage Max (Utest) | 3500 V |
| Test Voltage at Industrial Frequency for 1 Minute | 3500 V |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210004D0203 |
| Declaration of Conformity - CE | 9AKK106713A5539 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| GL Certificate | 1SDL000163R0062 |
| Instructions and Manuals | 1SDH000437R0001 |
| Instructions and Manuals (Part 2) | ITSCE-RH0100001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39121100 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG ABB TMAX XT EN.pdf | 70 Mbytes |
|
| T5V 400 PR221DS-LS/I In400 4p F F - ABB - T5V400 - 1SDA054389R1 | 91 Kbytes |
![]() |
| T5V400 1SDA054389R1 ABB T5V 400 PR221DS-LS/I In 400 4p F F | 80 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.