Product successfully added to your shopping cart
1SDA054345R1
ABB
1
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax" > T5
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 140faa68-0988-4edc-9617-4e5500b1ad48 China |
| Simplified SCIP | 710a583f-69f8-4ee8-a957-38e0414212ab Hungary |
| c6953311-8555-409f-afb5-983ad5bf2381 France | |
| 88cd3c60-8fe7-44e8-8955-fddbe3f449d1 Belgium | |
| 4d401c0b-3d8c-40e7-a57d-2305f3d3f97b Spain | |
| 197615bb-5059-493f-be1c-7ea65a0467ee Sweden | |
| 73a795ea-b8c0-453e-bb03-3e12cb1248b1 Germany | |
| 682ffa4b-cd2e-4a8f-b0b8-2081cf7834a6 Germany | |
| 29744247-cb52-4d0a-bba4-db2d34d8e7b5 Bulgaria | |
| 8d8df28c-30e2-4845-bfa9-7b769142aa5e Portugal | |
| 5d677df7-d77a-48eb-8d80-ea4e906812cc France | |
| 87c96c35-db7a-4e23-b045-4a93dae54fff Poland | |
| 65234107-6062-4534-8fe2-0f0ec623f85a Sweden | |
| 5f1b0e25-ddb0-4f67-8dd6-18a58bc9570f Hungary | |
| dd9855c9-573c-4d80-bb2b-2a8e7a5d24ac Poland | |
| 61d00d68-f3c1-4e67-874e-a35dc364175d Netherlands | |
| 77fafa11-19a1-4f01-8c5b-fa6a75f50d4b Estonia | |
| 7f2f6344-573b-4c35-b02c-d1ea2dd77383 Greece | |
| 14dfcd8b-ee10-4de8-a328-1d507e91b980 Germany | |
| 12973ec6-b681-498c-b0f4-9d7ce8efaff2 Croatia | |
| c3214853-312b-4d15-9c73-f994a3de7437 Poland | |
| 7a25d768-7a45-4537-9475-20b76e5c3e9e Norway | |
| 03db7190-1fdc-4d3e-a7d0-8ec361f37164 Czech Republic | |
| 8668b4ed-01c9-4b39-b37e-5a12f82deba5 Finland | |
| 72ab776b-acbf-4d12-8bd0-4c79aad094fd Belgium | |
| 625711c0-8976-4387-9403-1fd1f2b63f78 Germany | |
| dd87a6a8-b847-43e6-88c1-2c5133ddfbfc Denmark | |
| 6e5dc05d-8c92-41c0-b526-6ed10ceacad4 Germany | |
| Environmental | |
| Environmental Information | 9AKK10103A1056 |
| 9AKK108467A6707 | |
| Ordering | |
| E-Number (Finland) | 3655370 |
| E-Number (Norway) | 4384065 |
| EAN | 8015644554439 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 186 mm |
| Product Net Height | 205 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 6.2 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 248 mm |
| Package Level 1 Height | 240 mm |
| Package Level 1 Depth / Length | 285 mm |
| Package Level 1 Gross Weight | 6.2 kg |
| Package Level 1 EAN | 8015644554439 |
| Additional Information | |
| Product Main Type | SACE Tmax T |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Suitable For | T5 |
| Suitable for Product Class | Moulded Case Circuit Breakers |
| Version | F |
| Technical | |
| Electrical Durability | 7000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 4P |
| Power Loss | at Rated Operating Conditions per Pole 16.5 W |
| Rated Current (In) | 400 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 40 kA | |
| (500 V AC) 30 kA | |
| (690 V AC) 25 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 5 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 40 kA | |
| (500 V AC) 30 kA | |
| (690 V AC) 25 kA | |
| Rated Uninterrupted Current (Iu) | 400 A |
| Release | PR222DS/P-LSI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | T5 |
| Terminal Connection Type | Fixed Circuit-Breakers |
| Front | |
| Test Voltage Max (Utest) | 3500 V |
| Test Voltage at Industrial Frequency for 1 Minute | 3500 V |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210004D0203 |
| Declaration of Conformity - CE | 9AKK106713A5539 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| GL Certificate | 1SDL000163R0062 |
| Instructions and Manuals | 1SDH000437R0001 |
| Instructions and Manuals (Part 2) | ITSCE-RH0100001 |
| Instructions and Manuals (Part 3) | 1SDH000436R0502 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39121100 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG ABB TMAX XT EN.pdf | 70 Mbytes |
|
| T5S 400 PR222DS/P-LSI In400 4p F F - ABB - T5S400 - 1SDA054345R1 | 91 Kbytes |
![]() |
| T5S400 1SDA054345R1 ABB T5S 400 PR222DS/P-LSI In 400 4p F F | 80 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.