Product successfully added to your shopping cart
1SDA054319R1
ABB
1
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 1d9ab2b5-6a37-4968-b8f8-9de2dd1dd98c China |
| Simplified SCIP | a3e9f0e3-7b5c-4103-8366-3bf3448a9358 Greece |
| 2ef32bfa-4e1f-4361-8c3e-8ae1f5379edb Belgium | |
| 9794b810-db70-4295-96e5-39e104a34fa0 Sweden | |
| 3b6df653-5961-40cc-ac97-3a8e2d4f5fb3 France | |
| 52dab2a2-cfb8-40ff-999c-c105b66430ea Germany | |
| 7c5ddcac-13bb-4ca3-909b-509e71072c69 Netherlands | |
| 90299f81-bdfa-4ba0-a794-d1798c86295b Germany | |
| 9c53a709-19d4-4e8d-9487-4eea8888a19f France | |
| d50e8cd4-a1dc-4239-a81c-19a1b73225cc Sweden | |
| 9481ee68-b602-4e31-88b9-e48c5583ae10 Poland | |
| cc735283-cd26-4a7e-b040-a0e874b93b79 Poland | |
| 52afe2d2-51ce-42c1-ae28-bfd5d1d131df Bulgaria | |
| 669700e5-6dae-48d8-a82d-f66ab68af155 Norway | |
| 3b671810-f740-4d4d-bab6-bd5b4a646479 Germany | |
| e85fb3a5-fdd1-4170-be14-c1fda923c0b6 Finland | |
| 58f698e2-6cde-4cae-bb76-e740a609a1cd Poland | |
| 380bcaaf-ac48-4ca0-893e-666f4225b01e Portugal | |
| 5c37cc00-0337-44d1-afa0-e0b377472114 Czech Republic | |
| f5ef8ee0-1a6f-4c41-b3a6-3088f151bac5 Germany | |
| 2be6aa44-7692-4dd4-8654-31a18cab9978 Germany | |
| 46dde77b-b462-4af7-b7cc-44cf10783293 Denmark | |
| 4231cd4d-ebb9-4843-9b41-3e7d528c63c8 Hungary | |
| dc4a9486-6d19-461c-a8e6-cb1bc3003b05 Spain | |
| Environmental | |
| Environmental Information | 9AKK10103A1056 |
| 9AKK108467A6707 | |
| Ordering | |
| E-Number (Finland) | 3655528 |
| E-Number (Norway) | 4384042 |
| EAN | 8015644552640 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 140 mm |
| Product Net Height | 205 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 5.1 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 248 mm |
| Package Level 1 Height | 240 mm |
| Package Level 1 Depth / Length | 285 mm |
| Package Level 1 Gross Weight | 5.1 kg |
| Package Level 1 EAN | 8015644552640 |
| Additional Information | |
| Product Main Type | SACE Tmax T |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Suitable For | T5 |
| Suitable for Product Class | Moulded Case Circuit Breakers |
| Version | F |
| Technical | |
| Electrical Durability | 7000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | at Rated Operating Conditions per Pole 16.5 W |
| Rated Current (In) | 400 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 70 kA |
| (230 V AC) 70 kA | |
| (380 V AC) 36 kA | |
| (400 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 30 kA | |
| (500 V AC) 25 kA | |
| (690 V AC) 20 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 5 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 70 kA |
| (230 V AC) 70 kA | |
| (380 V AC) 36 kA | |
| (400 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 30 kA | |
| (500 V AC) 25 kA | |
| (690 V AC) 20 kA | |
| Rated Uninterrupted Current (Iu) | 400 A |
| Release | PR221DS-I |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | T5 |
| Terminal Connection Type | Fixed Circuit-Breakers |
| Front | |
| Test Voltage Max (Utest) | 3500 V |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210004D0203 |
| Declaration of Conformity - CE | 9AKK106713A5539 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Instructions and Manuals | 1SDH000437R0001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39121100 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG ABB TMAX XT EN.pdf | 70 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.